Temperature Transmitter Calibration

แชร์
ฝัง
  • เผยแพร่เมื่อ 21 ต.ค. 2024
  • Temperature Transmitter Calibration

ความคิดเห็น • 30

  • @jroar123
    @jroar123  12 ปีที่แล้ว +1

    This technic uses equipment that is traceable, which means that its accuracy can be traced back to an international standard. The RTD calibrator simulates the exact signal that would be produced by the RTD to the transmitter. Therefore an RTD simulator such as the Fluke 712 RTC Process Calibrator, Fluke 724 Temperature Calibrator, or Altek 211 would be recommended to calibrate a Temperature Transmitter. A dry block or dry well would be used to test the RTD probe itself.

  • @jroar123
    @jroar123  11 ปีที่แล้ว +1

    The reason that they used the WD40 was to give the transmitter the worked-on look. If inspected the inspector would know that someone had worked on it. I know that sounds silly but it worked. It also was a way to clean the outside of the transmitter.

  • @OmarVillanueva7
    @OmarVillanueva7 12 ปีที่แล้ว

    Great Video, i have a question.
    What is the spray that the engineer applies over transmitter at the end of the video?

  • @qbranch88
    @qbranch88 12 ปีที่แล้ว

    So you're manipulating the resistance that should be generated by the RTD when it's heated/cooled? I guess a dry block would do the same thing, only you're applying the actual temperature to the RTD and seeing what it generates. Those damn things are so hard to keep the temp steady though. Is this method much more accurate?

  • @kieranhimself9124
    @kieranhimself9124 5 ปีที่แล้ว +1

    no floating shields?

  • @elahlynews8249
    @elahlynews8249 7 ปีที่แล้ว +1

    انا مبتدئى فى قسم الاجهزة الدقيقة ممكن شروحات تفيدنى وتعلمنى او مواقع فيها شروحات مترجمه

  • @ASkhan002
    @ASkhan002 8 ปีที่แล้ว +1

    nice video. i like its explaination....

  • @romeodeseo
    @romeodeseo 11 ปีที่แล้ว

    I am sure it is WD40 ,maintenance people not only instrument use in order to clean and spread some lubrication to the equipment that is being maintained.

  • @dineshdevprasadj2891
    @dineshdevprasadj2891 10 ปีที่แล้ว

    good video!i having one problem After calibration local display unit in the TT was showing the correct reading but while transmitting the value to emerson flowbloss computer its faulty reading .kindly give me a solution

  • @chrismoon8263
    @chrismoon8263 12 ปีที่แล้ว

    This is a very old school way to calibrate a TT. Modern process calibrators from the like of GE, Beamex or Fluke have RTD simulation so a look up table required when using a decade box is elimated as they are calibrated and scaled in deg C or F. They also have HART com's as standard so the 475 shown in the video is elimated also. Using documenting features so you get your as found / left results and error calculations would massively speed up this video!

  • @TheBryce2007
    @TheBryce2007 6 ปีที่แล้ว +3

    I can't understand a word they're saying.

  • @darby102871
    @darby102871 4 ปีที่แล้ว +1

    so many alibaba, 1 man worked while 3 are supervisors muahahaha

    • @jroar123
      @jroar123  4 ปีที่แล้ว +1

      Arnold Chavez : Actually, they were in training while watching how to do the work.

    • @darby102871
      @darby102871 4 ปีที่แล้ว

      @@jroar123 ok noted

  • @Kimck098
    @Kimck098 11 ปีที่แล้ว

    This is true, but these methods don't teach anyone about how the simulation works or where those values or resistance lookup tables originate from. Not everyone has fancy Beamex, Flukes etc. But yes I completely agree, it is a far more /efficient/ method.

  • @فهدالزريعي-ز8ق
    @فهدالزريعي-ز8ق 8 ปีที่แล้ว +1

    What a bummer when a message appears on the sender of the pressure device Pressure transmitter
    Message appears on the screen sender Zguet
    [Fail modu]

  • @vinothfluide38
    @vinothfluide38 6 ปีที่แล้ว +1

    how to calibration hart positioner with 475 communicater

  • @atifbaig4193
    @atifbaig4193 7 ปีที่แล้ว +1

    just i want i q sir
    how to check pressure calibrator infield bus?

    • @Khustar9769
      @Khustar9769 7 ปีที่แล้ว +1

      Assalamo alaikum

  • @فهدالزريعي-ز8ق
    @فهدالزريعي-ز8ق 8 ปีที่แล้ว +1

    Pressure transmitter
    ماهي المشكله عنما تظهر رساله على جهاز مرسل الظغط ترنزميتر Pressure transmitter
    رسالة تظهر على شاشة مرسل ضغط
    [fail module]

  • @ماجدالتميمي-ل7د
    @ماجدالتميمي-ل7د 6 ปีที่แล้ว +1

    عندي جهاز 375 و 475 اريد ابيعهن

  • @flowmeters-tx
    @flowmeters-tx 11 ปีที่แล้ว

    Great site job

  • @ryancustodio4279
    @ryancustodio4279 11 ปีที่แล้ว

    very simple

  • @muhammadmalikgroup7869
    @muhammadmalikgroup7869 6 ปีที่แล้ว

    I am instrument technican .i am know work in instrument filed.i am before 3 year i m job in cement plant. I am DAE electronic instrument. I want a job in Sudia ariba city besha..i am also work in Sudia ariba city besha. انا معلوم اليكتركل انسيڑرمنت قل شغل معلوم انا عغبا شغل

    • @jroar123
      @jroar123  6 ปีที่แล้ว

      Muhammad Saeedmalik 12345 Please forward your resume to: john.rohrer@icloud.com and I will forward it to my contacts. Please note that I am not associated with any company and therefore do not expect compensation in any way, shape, or form.
      yrja 'iirsal sirtik aldhdhatiat 'iilaa: john.rohrer@icloud.com wasa'arsulha 'iilaa jihat alaitisal alkhasat bia. yrja mulahazat 'aniy ghyr mrtbt bi'ay sharikat wabialttali la 'atawaqae altaewid bi'ay shakal 'aw shakal 'aw shukl.
      يرجى إرسال سيرتك الذاتية إلى: john.rohrer@icloud.com وسأرسلها إلى جهات الاتصال الخاصة بي. يرجى ملاحظة أني غير مرتبط بأي شركة وبالتالي لا أتوقع التعويض بأي شكل أو شكل أو شكل.

  • @dennyfuul
    @dennyfuul 12 ปีที่แล้ว

    LOL thats my job :)

  • @triskeliontaugammaphi7141
    @triskeliontaugammaphi7141 11 ปีที่แล้ว

    w 40 pawala sa taay.lol