safety switch/fuse line to ground wiring

แชร์
ฝัง
  • เผยแพร่เมื่อ 29 ก.ย. 2024

ความคิดเห็น • 33

  • @ariesjpinayvlogs1406
    @ariesjpinayvlogs1406 2 ปีที่แล้ว +2

    Magandang content ito.Maishare sa bro ko ulit

  • @dochanneltv-tw3ql
    @dochanneltv-tw3ql 11 หลายเดือนก่อน +1

    boss paano yan ilipat pg breaker na?kc prbnsya nmin is line to ground sa knla

  • @crisceljohngation2148
    @crisceljohngation2148 14 วันที่ผ่านมา

    Boss pwede ba na 30A at 60A ang gagamit mo na fuse ng sabay?

    • @armvtugadevlog4475
      @armvtugadevlog4475  9 วันที่ผ่านมา

      di pwede pag sa sitwasyon sa video. pwede depende kung papano iwiniring, papano idenesign at kung papano ginamit ang mga overcurrent devices

  • @edgardoagcoltourvlog8144
    @edgardoagcoltourvlog8144 2 ปีที่แล้ว +1

    You're doing great lods keep it up

  • @crisceljohngation2148
    @crisceljohngation2148 14 วันที่ผ่านมา

    Ilang amp ginamiy mo na fuse boss

    • @armvtugadevlog4475
      @armvtugadevlog4475  9 วันที่ผ่านมา

      its just an example kung papano iwiniring sa line to ground ang fuse sa loob ng fusebox kaya no need pa na alamin if ilang ampere rating yung fuse.

  • @benjieduka4100
    @benjieduka4100 11 หลายเดือนก่อน +1

    galing boss

  • @bevedio1578
    @bevedio1578 3 หลายเดือนก่อน

    Sir ok pang ba sa fuse 20amp

    • @armvtugadevlog4475
      @armvtugadevlog4475  3 หลายเดือนก่อน

      depende sa calculated load & san mo gagamitin (main or bramch).

    • @armvtugadevlog4475
      @armvtugadevlog4475  3 หลายเดือนก่อน

      base sa pec ang min. main overcurrent protection - 60amp & min. main feeder wire - no. 6 awg.

  • @badodlessss
    @badodlessss 4 หลายเดือนก่อน

    Sir pwede po ba yung 3.5 mm na wire sa fuse na 30 Ampere???

    • @armvtugadevlog4475
      @armvtugadevlog4475  4 หลายเดือนก่อน

      dapat match yung ampacity nung wire sa overcurret protection.

    • @armvtugadevlog4475
      @armvtugadevlog4475  4 หลายเดือนก่อน

      yung 3.5mm or no. 12awg na yan ay may ampacity na 20amp lang kaya di pwede. pag nangyari na may short circuit, overload or faulty wiring, yung wire ang iinit at masusunog imbes na fuse dapat ang bumigay. yan yung mga sanhi ng sunog pag di match ang ampacity nung wire sa kanyang overcurrent protection.

  • @cardosaydali5758
    @cardosaydali5758 ปีที่แล้ว

    gagawin mo lang yan pag mag lalagay ka ng grounding rod naka baon sa lupa kung wala kang ground wag mo gawin yan delicado

    • @armvtugadevlog4475
      @armvtugadevlog4475  ปีที่แล้ว

      yes, matic yan pag line to ground power source, single phase 2 wire & dapat line to ground ang mga wiring connection din para may silbi ang pagkaline to ground power source niya.

    • @armvtugadevlog4475
      @armvtugadevlog4475  ปีที่แล้ว

      yung tungkol sa remedyo pag busted fuse yung isang linya ay temporary na remedyo lang yun basta alam mo total load ng pinoprotektahan na sirketo para magamit.
      th-cam.com/video/L2p3JFt67UA/w-d-xo.html
      yung iba pag busted fuse yung isa ay binabalutan ng aluminum foil para dumaloy ulit ang kuryento sa linya nito pero di ko rekomendado yun.

    • @cardosaydali5758
      @cardosaydali5758 ปีที่แล้ว +1

      @@armvtugadevlog4475 kung busted fuse palitan mo ng bago

    • @armvtugadevlog4475
      @armvtugadevlog4475  ปีที่แล้ว

      oo naman matic yan. temporary remedy lang para magamit basta alam ang total load sa minimum load nung circuit & naiintindihan ang electrical & e. codes.

    • @ronaldlana1955
      @ronaldlana1955 8 หลายเดือนก่อน

      Tanong q lng Po d parang useless na Ang Isang fuse diyan.

  • @cardosaydali5758
    @cardosaydali5758 ปีที่แล้ว

    anong libro yan gamitin mo saan mo nabili yan

    • @armvtugadevlog4475
      @armvtugadevlog4475  ปีที่แล้ว

      meron yan sa national book store. architectural utilities 2 -electrical & mechanical equipment. ang author si Archt. George S. Salvan.

  • @bonsjovi6461
    @bonsjovi6461 ปีที่แล้ว

    paano po idol kung magpakabit ako ng aircon tapos naka fuse box ako ,pede ko bang idagdag dyan sa fuse box 1 circuit ng aircon.?

    • @armvtugadevlog4475
      @armvtugadevlog4475  ปีที่แล้ว

      lahat ng fuse may nakamatch na wire depende sa ampacity ng gagamitin mong fuse. 60amp ang minumum ng main na no.6 awg ang kanyang match na wire. Meron din mga branches para sa mga fuse, gamitan mo ng fuse cut out para makagawa ka ng mga branches para sa sinasabi mong aircon.

    • @bonsjovi6461
      @bonsjovi6461 ปีที่แล้ว

      @@armvtugadevlog4475 pede ba maka request po sir ng video ?yung lumang fuse box po dagdagan ng circuit sa aircon.salamat po

    • @armvtugadevlog4475
      @armvtugadevlog4475  ปีที่แล้ว

      th-cam.com/video/zSHWVlPUGwU/w-d-xo.html

    • @bonsjovi6461
      @bonsjovi6461 ปีที่แล้ว

      @@armvtugadevlog4475 salamat idol na unawaan kona po salamat

    • @armvtugadevlog4475
      @armvtugadevlog4475  ปีที่แล้ว

      th-cam.com/video/K_vFMf9KHpY/w-d-xo.html

  • @mi-vy8xm
    @mi-vy8xm ปีที่แล้ว

    sir ano po ang nadedetect ng fuse box?salamat po

    • @armvtugadevlog4475
      @armvtugadevlog4475  ปีที่แล้ว

      fuse box, wala except yung sa overcurrent device w/c is fuse or ckt breaker.

    • @cardosaydali5758
      @cardosaydali5758 ปีที่แล้ว

      @@armvtugadevlog4475 anong wala bakit siya ginagamit dati kung wala nadedetct circuit breaker at fuse same lang sila ng function

    • @armvtugadevlog4475
      @armvtugadevlog4475  ปีที่แล้ว

      @@cardosaydali5758 sa tanong ni mi-vy8xm , ano daw ang nadedetect ng FUSE BOX. syempre ang sagot diyan ay protective covering lang yan ng fuse. casing ng fuse kumbaga.
      buti sana kung ang tanong ay ano ang nadedetect ng fuse. syempre pag fuse ang tanong, sasagutin ko ng protective device siya kaya siya ang nagdedetect ng short circuit, faulty wiring, or overcurreent dahil siya mismo ang nadtritrip para mabusted at maputol yung may problemang linya same sa function ng circuit breaker.