LiFePO4 Top Balance Tutorial Lithium Ion DIY Beginner Friendly

แชร์
ฝัง
  • เผยแพร่เมื่อ 2 ก.พ. 2022
  • I may use affiliated links for the products I recommend. This does not affect you in any way.
    Get in touch; solarpowerchannel@hotmail.com
    SOK Batteries
    US: www.us.sokbattery.com/?ref=wJ...
    Europe & UK: www.europe.sokbattery.com/?re...
    LiFePO4 BMS (BLUETOOTH) (AliExpress)
    s.click.aliexpress.com/e/_99cHDO
    Power Supply:
    s.click.aliexpress.com/e/_99J2OR
    Battery Capacity Tester:
    s.click.aliexpress.com/e/_APwawv
    WATE Charger 14.6v (AliExpress)
    s.click.aliexpress.com/e/_AF5yzR
    LiFePO4 Battery 12v Always use a BMS for safety. (AliExpress)
    s.click.aliexpress.com/e/_AXYpsq
    Renogy 100Watt Folding Suitcase Solar Panel, PWM & MPPT
    Renogy Products
    UK: renogy.sjv.io/c/3275883/12756...
    US: renogy.sjv.io/c/3275883/12001...
    Australia: renogy.sjv.io/c/3275883/13552...
    Canada: renogy.sjv.io/c/3275883/13552...

ความคิดเห็น • 48

  • @Crazy_Chicken_and_Lakrits
    @Crazy_Chicken_and_Lakrits 2 ปีที่แล้ว +20

    When You want to measure voltage over each cell individually I think they must be separated and not connected in parallel. When connected in parallel, as in Your video, of course You will measure exactly the same voltage, as You measure over all cells, not each cell individually.

    • @SolarPowerChannelwithChris
      @SolarPowerChannelwithChris  2 ปีที่แล้ว +1

      Hello, thanks for watching. I find the cell voltages where different even connected in parallel on the power supply (remember I really unbalanced them). It was only once they was top balanced and the power supply read 0amps did the cells read the same.

    • @Jozefszky
      @Jozefszky 2 ปีที่แล้ว +7

      Very good point @pc55093 , I think the same. If you connect the cells with the bus bars, the voltage will be the same doesn't matter where you measure. An other thing what was strange in every balancing video, they just simply connect the cells paralell with the bus bars, and after it they start to play with the 3.6 volt charging. My understanding is, if you connect different SOC cells together, they will balance the voltage levels immediately, but with huge current flow, which is very bad for the batteries. Why nobody is talking about this, just connect the cells like no one cares????

    • @DuaneStorey
      @DuaneStorey ปีที่แล้ว +4

      @@SolarPowerChannelwithChris You're just seeing repeatability issues with your multimeter. If they are all connected in parallel, by definition they have to be at the exact voltage. As others said, you need to disconnect them to test individually.

    • @ploegmma
      @ploegmma 5 หลายเดือนก่อน +3

      😂 you see, everywhere I measure, same voltage

    • @XXXCRSPL
      @XXXCRSPL 3 หลายเดือนก่อน

      How else are you going to check them when the banks together? Only way and each cell even together have their own voltage

  • @SalmonKing52
    @SalmonKing52 3 หลายเดือนก่อน +2

    Hi Chris….I’m still trying to find that alternate method you mentioned a link in the description but I don’t see it…

  • @seans5960
    @seans5960 6 หลายเดือนก่อน +1

    Thank you for this, very well explained

  • @densito
    @densito 4 หลายเดือนก่อน +2

    I have been told not to bring the charge up to 100%...what is your view on it?

  • @andytaylor3594
    @andytaylor3594 2 ปีที่แล้ว

    Hi Chris,
    I had about 0.4a left on my PSU and I had to stop it (lack of availability of devices and my laptop was about to die!). I have 2 cells reading 3.59 and 2 cells reading 3.60. How important it is for me to go back through the process of top balancing with these values? Am I able to discharge and recharge the battery pack a few times to sort the out of balance out? Additionally, I need to test the capacity of this pack. I don't have the fancy device you have. Can I use something that I know the continuous discharge value i.e. my extractor fan and time it?

  • @thuggfrogg
    @thuggfrogg 2 ปีที่แล้ว +1

    Is it safe to leave the charger set at 3.65V connected to the cells when they're topped off, as you did at the 4:25 mark? I'm wondering if I can use this method to charge my cells overnight without worrying. Thank you!

  • @smarty7198
    @smarty7198 2 ปีที่แล้ว

    Hi Chris, need some advice please.
    Can I use a SKYRC T200 balance charger to do my initial charge and balance at the same time on my 230ah lifepo4 prismatic cells? Charger current rate is 0.1 - 12amps and it has port for 2-6s balance leads. Does that mean I can charge/balance the cells without using my jbd bms as the charger is kind of acting as the bms for that charging/balancing period?(obviously I will be using the jbd bms when the battery goes into proper use in my van)
    Also it has a storage charge function so could i do the initial charge & balance then put the battery into storage charge whilst I finish my van off. Anything n to add to that?
    I’m hoping I can use this charger as it will save me buying a power supply to only use it once.
    Many thanks.

  • @CHloras
    @CHloras ปีที่แล้ว +2

    Current is measured by amps, not by volts (0:15) !

  • @markfromwestcoastwoodcraft7633
    @markfromwestcoastwoodcraft7633 9 หลายเดือนก่อน +1

    once the cells reach 3.65 volts and the power supply amperage drops to zero , how long do you leave the cells in this state of charge and connected in parallel ?

  • @charlieisgnarly
    @charlieisgnarly 4 หลายเดือนก่อน

    You mentioned that you would need 56v charger for charging a 48v batteries (8 cells) however the Lab PSU that I ordered will only do 30v at 10a, does that meant that I can only balance 4 cells (12v) at a time?

  • @bambino3162
    @bambino3162 2 ปีที่แล้ว

    I am a big time amateur. I see that you talk about cells , does that mean that a full batterie (12v 200ah LIFEPO4) does not to be top balanced? Could you please illustrate it with batteries?

  • @nathanprofit3966
    @nathanprofit3966 ปีที่แล้ว

    please how many A of current do i need to charge 32pcs of cell of 200Ah battery to charge my battery quickly?

  • @elpihendi6793
    @elpihendi6793 2 ปีที่แล้ว +1

    Is it normal to see lower voltage then I set during charging ? Thank you for content !

  • @KoiAquaponics
    @KoiAquaponics ปีที่แล้ว +1

    I'm confused, so if they begin as out of balance, when the charger pushes current through what happens to the cells that reached the max voltage first? they're still receiving current right? Do we remove the ones that reach 3.6v out of the charger?

    • @SolarPowerChannelwithChris
      @SolarPowerChannelwithChris  ปีที่แล้ว

      Hello, thank you for watching. Once the cells reach 3.6v they stop accepting any more current. Thus you leave all 4 cells connected in parallel until all 4 show no current. Cells 1 and 2 maybe 3.6v cells 3 and 4 could be 3.4v, regardless leave it all connected. The cells won't keep charging as they have balanced with the charger. I made the video ages ago but you will see the amp display on the supply unit starting to drop.. Indicating the cells are almost charged.

  • @abelramos8652
    @abelramos8652 ปีที่แล้ว

    Hi Chris! Can I balancing them with the PV power supply and save some money off the charger? My cells are arriving … thanks!

    • @SolarPowerChannelwithChris
      @SolarPowerChannelwithChris  ปีที่แล้ว

      Hello, you may find the cells are pretty balanced already. Charge them up on the PV with your solar change controller and when the BMS does the disconnect. Check the individual cell voltages. You may be ok..

  • @Veveve1
    @Veveve1 2 ปีที่แล้ว +2

    Measuring the voltages while connected - wont yield different voltages

  • @nathanprofit3966
    @nathanprofit3966 ปีที่แล้ว

    i don't understand i have 32 cells of lithium 200A battery coming from China you saying i should use higher voltage?

  • @bobspeller2225
    @bobspeller2225 2 ปีที่แล้ว

    What advice would give for my project.
    I have an 8 x 8 ft shed at the top of my garden, this puts it at the top of a hill some 120ft from the barn.
    I would like to set up a solar system for lights, and to use some power tools, This will not be used on a regular bases and may be left un-attended for three months at a time.
    What would you recommend? I look forward to hearing from you. Many Thanks Bob

    • @SolarPowerChannelwithChris
      @SolarPowerChannelwithChris  2 ปีที่แล้ว

      Hello Bob, thanks for watching. What is your budget? How much direct sun does your shed get? What power tools we talking?

    • @Bokul112
      @Bokul112 6 หลายเดือนก่อน

      @@SolarPowerChannelwithChrishello sir
      Daly bms is good or jk please tell me

    • @SolarPowerChannelwithChris
      @SolarPowerChannelwithChris  6 หลายเดือนก่อน

      @@Bokul112 seems fine..

    • @Bokul112
      @Bokul112 6 หลายเดือนก่อน

      @@SolarPowerChannelwithChris which one better sir

  • @justinbelote1768
    @justinbelote1768 ปีที่แล้ว +1

    Anyone know if it’s ok to use stranded 12 awg wire wire in place of bus bars? I don’t have enough bus bars and figured since it was low voltage and low amps it. Ight be fine. Anyone?

    • @SolarPowerChannelwithChris
      @SolarPowerChannelwithChris  ปีที่แล้ว +1

      That should be fine. Long as they are all roughly the same capacity. Dont want a rush of current.

  • @aspdotnet
    @aspdotnet ปีที่แล้ว +1

    Does the power supply become 0A automatically when batteries come to 3.65V?

  • @jamest.5001
    @jamest.5001 2 ปีที่แล้ว +1

    For those who don't know, there is a difference between nominal voltage and charge voltage,
    3.6 is charge voltage for LiFePo, and nominal for lipo is 3.7, so pay attention to the nominal voltage and chemistry of the cells...
    Or there could be 🔥😭

    • @SolarPowerChannelwithChris
      @SolarPowerChannelwithChris  2 ปีที่แล้ว

      Thanks for watching! Yes good point, I shall say this and be more clear in the future. As well as buying BMS.

  • @ovchannelag5238
    @ovchannelag5238 ปีที่แล้ว

    👍👍

  • @jS-yk5lc
    @jS-yk5lc ปีที่แล้ว

    Volt and amp for charge??

  • @basiceducation1131
    @basiceducation1131 5 หลายเดือนก่อน

    Hi bro ❤

  • @onemoment7368
    @onemoment7368 2 ปีที่แล้ว

    So you can't use 14.6v charger to balance them?

    • @SolarPowerChannelwithChris
      @SolarPowerChannelwithChris  2 ปีที่แล้ว

      Thanks for watching. No just to change them, as in lift there state of charge quicker then finish them off on the power supply. Charging them at 14.6v won't lift all the cells because the bms will do a disconnect. Safety reasons, always use a bms.

    • @beaker2000
      @beaker2000 2 ปีที่แล้ว

      No, you have to top off the cells individually or in parallel at the single cell voltage to assure they are at full capacity before putting them into a pack. Once they are in a pack, if properly top balanced before hand, they should stay in decent balance while the pack discharges and charges evenly across all cells.

  • @richardbenson7264
    @richardbenson7264 9 หลายเดือนก่อน

    Great video but needs to contsin so much more info

  • @jdehundt
    @jdehundt 6 หลายเดือนก่อน +1

    Are you really measuring the voltage on every cell with the busbars on? If there is no current flowing they are the same
    You lost al your credit for me

    • @SolarPowerChannelwithChris
      @SolarPowerChannelwithChris  6 หลายเดือนก่อน

      An old manager once said to me, explain like they know nothing. Never assume they know too. This goes with everything I do when passing on knowledge.

    • @pippi1970
      @pippi1970 3 หลายเดือนก่อน

      Agree!

  • @pandyinfrance3065
    @pandyinfrance3065 2 หลายเดือนก่อน

    You can't test individual voltages when they're connected in parallel.
    Learn some electrical theory before making 'instructional' videos.