My Consumer Unit Secrets 🤫 - How to install a Consumer Unit/Fuse Box

แชร์
ฝัง
  • เผยแพร่เมื่อ 24 มี.ค. 2021
  • My Consumer Unit Secrets 🤫 - How to install a Consumer Unit/Fuse Box
    Join me as I show you an in-depth look into how I install a replacement consumer unit/fuse box in a domestic property. I share my secrets for how I get all the cabling and wired neat and tidy within the new consumer unit.
    🏷️ Today Video Sponsor:
    Tradify - Get 50% Off your first 3 months with Tradify using the discount code "ARTISAN" and this link: bit.ly/3qWjRkU
    Subscribe to our TH-cam Channel for more great electrical content: th-cam.com/users/artisanelectr...
    🧰🛠️ Tools Of The Day 👇
    Jackery 240 Portable Power Station use discount code JACKERY2021 until 31st march to get 20% off!: amzn.to/3c72Rnh
    🔔 Join This Channel To Get Access To Perks 👇
    ➤ / @artisanelectrics
    ✅ Check Out All Our Favourite Tools Here 👇
    ➤ www.amazon.co.uk/shop/artisan...
    -----Electricians Business Course-----
    📩 Sign Up To My Electricians Business Course Here And Get The First 4 Lessons Free 👇
    ➤ course.electriciansbusinessco...
    🔔 Subscribe to TOOLS4SPARKS TH-cam Channel 👇
    I Also Have A Dedicated TH-cam Channel About Tools:
    ➤ / tools4sparks
    -----TESLA REFERRAL CODE-----
    🚀 You Can Use My Referral Link To Get 1,000 Free Supercharger Miles On A New Tesla 👇
    ➤ ts.la/andrew24855
    -----MY ENERGY PROVIDER-----
    🐙 Get £50 credit when you switch to Octopus Energy 👇
    ➤ share.octopus.energy/zappy-sh...
    🏷️ DISCOUNT BUSINESS SUPPLIES 👇
    ➤ www.amazon.co.uk/tryAB/?tag=a...
    -----TRADES INSURANCE DISCOUNT-----
    If you need to renew your public liability insurance or need tools in van insurance, I recommend Rhino Trade Insurance, I've just renewed my insurance with them.
    🏷️ Use My Discount Code “ART5” and you get a 5% Extra Discount On Their Already Excellent Prices.
    ➤ www.rhinotradeinsurance.com/quote
    📞 or call 01162437904.
    📱 Don't Forget to Follow Social Media, FOLLOW US on Your Favourite Social Networks 📱
    📸 Artisan Electrics Instagram Account 👇
    ➤ / artisanelectrics
    🐦 Artisan Electrics Twitter Account 👇
    ➤ / artelectrics
    📓 Artisan Electrics Facebook Account 👇
    ➤ / artisanelectrics
    ADVERTS THAT SUPPORT THE CHANNEL:
    Thanks for your support!
    This video is for entertainment purposes only please do not attempt to copy or recreate. Do so at your own risk.
    #consumerunit #fusebox #artisanelectrics
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 1.1K

  • @artisanelectrics
    @artisanelectrics  ปีที่แล้ว +2

    Get a quote for a consumer unit upgrade here: www.artisanelectrics.co.uk/consumer-unit-replacement-4/

  • @woodydroneson
    @woodydroneson ปีที่แล้ว +4

    Great work, nice to see the pride in workmanship and the tidy cables ensure that you do not wire anything up incorrectly. My first house had a very badly installed distribution board, even though it was labelled as ground-floor and first-floor sockets when the first floor was not separated at all and even the main fuse cover was not correctly sealed with a wire security tab and it fell off! I replaced the fuse box for a more modern one at the time by myself before being qualified was a legal requirement, obviously, the previous electrician was either just a cowboy or knew less than me!

  • @webzterd
    @webzterd 3 ปีที่แล้ว +5

    I'm not a sparky or a trainee, but love a video like this. It's through videos like these that I've been able to "shop" what I would like to see replace my consumer unit i.e. the unit itself, AFDD, SPD, position, consideration for 3 phases etc etc. it enables a much more informed discussion to take place with a tradesman and following the work, I can look it and go "what is this spaghetti junction you have given me"?
    Glad to hear you call out that it was part p notifiable though.

  • @michaelkiddle3149
    @michaelkiddle3149 3 ปีที่แล้ว +20

    It's nice to see someone take pride in his work, so often these days people just don't bother.👍

    • @Lollol-ci7mc
      @Lollol-ci7mc 2 ปีที่แล้ว

      Why electric unit very in England.. Who is responsible Elizabeth

  • @stevejudd7777
    @stevejudd7777 3 ปีที่แล้ว +6

    Nice Video. As an Electrician who qualified under 15th Edition and then a refresher 16th Edition I have started to follow your videos to see what's changed. When doing Rewires i used to love doing the Consumer unit, locking yourself away for a couple of hours listening to our tune on the radio. I used to love doing them as they were one of the many ways to really show pride in your work. I used love doing Pyro work also. Again, a fiddly cable to master as an apprentice but once you knew how to spool it off the drum and dress it well you could really shine.

    • @mw0358mw
      @mw0358mw ปีที่แล้ว

      The customers that are happy to pay for quality are few and far between! Need to seal the top surface though 🤔

  • @stevedavis770
    @stevedavis770 2 ปีที่แล้ว +14

    The difference between a craftsman and a tradesman. Beautiful job. Takes more time and effort but certainly shows as an excellent job done that even someone who knows nothing about electrical installation can appreciate.
    Even a bodger like me is impressed.

  • @mrmarkdyde
    @mrmarkdyde 3 ปีที่แล้ว +99

    I always wondered what a “pen fault” was, now I know it’s when you leave the cap off your Sharpie...

  • @paulunderdown1460
    @paulunderdown1460 2 ปีที่แล้ว +1

    A man after my own heart. Pride in our work but also if another contractor does come in to carry out EICR our work gives confidence in the rest of the installation where they may not be able to see. Also these contractors may tell other contractors and wholesalers what good work we have done. Well done let’s encourage other sparks to keep up the standards.

  • @postersm7141
    @postersm7141 2 ปีที่แล้ว +10

    22:48 “ I usually take that in the bottom” well at least he’s honest lol. But seriously nice video!

  • @nickrundall
    @nickrundall 3 ปีที่แล้ว +46

    Nice work as always - bit alarmed to see you working with the cutout fuse opening exposed! My instructor always used to tell a story of someone he knew who did that and some dangling cable managed to find its way in and short circuit the supply knocking the whole street out and nearly killing the dude. Best to take the fuse out and reinsert the fuse holder. Stay safe!

    • @artisanelectrics
      @artisanelectrics  3 ปีที่แล้ว +7

      Thanks

    • @seanburgess9103
      @seanburgess9103 2 ปีที่แล้ว +3

      Bingo...Same as , know a Spark who touched the Lucy C.O and got the nickname E.T

    • @samgriffiths7609
      @samgriffiths7609 2 ปีที่แล้ว

      Aaah you'll be alright, just don't stick your finger in it 😂

    • @TheMessele
      @TheMessele 2 ปีที่แล้ว +1

      I always keep an empty cartridge, saves the ballache of removing the fuse from the holder

  • @christopliss9947
    @christopliss9947 3 ปีที่แล้ว +7

    Great trick how to get rid of kinks in the conductors, tried it myself the other day and it worked a treat! Your CU cable dressing is commendable.

  • @jameswright7977
    @jameswright7977 2 ปีที่แล้ว +1

    Currently in the beginning stages of training to become an electrician and I can't stop watching these videos, a lot of stuff is still pretty foreign to me but slowly picking it up

  • @TheWebstaff
    @TheWebstaff 3 ปีที่แล้ว +8

    A true professional makes every job they do look easy...

  • @richardcornelius220
    @richardcornelius220 3 ปีที่แล้ว +7

    Its refreshing to find a cu with ring finals marked. I tend to put coloured sleeving over one of the legs to identify them for continuity. Keep up the great work fella.

  • @nekosarantango865
    @nekosarantango865 11 หลายเดือนก่อน +5

    For labelling cables you can write on white heatshrink with fine pen and the text is preserved when it's shrunk

  • @tonysutcliffe9849
    @tonysutcliffe9849 2 ปีที่แล้ว +1

    Good job. I also use the cable markers but rather than using a numbering system I use a code. The reason for this is that if any circuits are added the then the cable numbers could change whereby if you use US or UR for Upstairs Sockets or Upstairs Ring, that cable will always serve that circuit, no matter what happens to the fusebox. Nice to see someone who takes pride in their work,

  • @GrantWyness
    @GrantWyness 2 ปีที่แล้ว

    Blimey, you are a refreshing spark. Your vids are a public service reminder to all those out there that do the right thing, and a gift to those that might want to chance their arm. If anyone follows your vids to-the-letter, the world is in a better place.

  • @stranraerlad1
    @stranraerlad1 2 ปีที่แล้ว +3

    Great video and nice tidy workmanship. As a retired electrician I love watching theses videos which bring me up to date on new regs and techniques. My only gripe was when you were ID-ing the cables, the earth wires (old school) /CPCs were in danger of going into you eyes I know you had safety glasses but they won't protect your eyes when sitting on top of your head. Still it did not distract me from watching a good job being done. Thanks

    • @ericmcrae7758
      @ericmcrae7758 ปีที่แล้ว

      I agree with your comment re the earth wires, I had a habit of folding the end away from your face so you would only get a rounded wire if the worse happened.

  • @riad90
    @riad90 3 ปีที่แล้ว +103

    What beautiful and neat workmanship! One humble suggestion is that I would probably have fitted an isolator switch in place of that Henley block (you can get 100A Wylex ones for under £15). P.S. Congratulations on the 50.1K subscribers!

    • @democracyforall
      @democracyforall 2 ปีที่แล้ว

      I was always confused about the neutral and live incoming wires and how they get connect to the other fuses. This one video did it all for me. I have never installed a consumer unit but work as a Multiskilled Eningeer I am pretty sure I can do it so fast now like though I been working on it for 20 years.

    • @jamesclarke8295
      @jamesclarke8295 2 ปีที่แล้ว +5

      Completely agree, great install, very very neat! I too would’ve put a 100A disconnector on the meter tails and if I was being particular a 230V sticker on the front of the consumer unit, just to make it idiot proof 😜

    • @bpomowe224
      @bpomowe224 ปีที่แล้ว +1

      @@jamesclarke8295 If you want to make it idiot proof, you need to cut the power back at the transformer.. just saying ;)

  • @Mark_Lacey
    @Mark_Lacey ปีที่แล้ว

    Jordan, never underestimate the usefulness of these videos or who is watching. I live in Thailand and have just built a new kitchen. My missus got the local sparks in to install a new consumer unit, cooker, water heater, socket and lighting circuits. He absolutely butchered the CU box, installed three radials to sockets instead of a ring main, didn't install earths to metal light fittings (attached to the steel-framed kitchen roof) and switched the fucking neutrals on the lighting circuit. I am in the process of re-installing and your videos, whilst I know are not meant to be 'instructional' for DIYers, are proving essential.

    • @LarsPW
      @LarsPW 6 หลายเดือนก่อน +1

      Ring circuits are an exceptional british method, many western industrial countries are not used to this kind of wiring and do not need it.

  • @keis9396
    @keis9396 3 ปีที่แล้ว +3

    Buen video! lo bueno de youtube es que ahora los subtítulos automáticos tiene la opción de traducir al español, yo no se nada de ingles, pero con esa opción me ha ayudado harto ver videos en ingles y aprendo harto viendo los puntos de vistas de otros electricistas del mundo. Saludos desde Arica (Chile)

    • @NathanOlooney
      @NathanOlooney 3 ปีที่แล้ว +3

      Que bien! Me alegro que puedas entender lo que creamos en el canal. Saludos 👋🏼

  • @anthonysykes542
    @anthonysykes542 2 ปีที่แล้ว +6

    You're like the Bear Grylls of the electric industry! I like how you take pride in your work and give it your best effort. An amazing video and very informative. P.S, I would happily sort your numbering system box out, my O.C.D would kill me to work with it like that lol. Keep up the good work, you gained another sub!

    • @seanburgess9103
      @seanburgess9103 2 ปีที่แล้ว

      Perfect way of doing these, but Companies are Hour Conscious . Fast Fast Faster

    • @mw0358mw
      @mw0358mw ปีที่แล้ว

      Just get brother heat shrink tape our industrial numbering is long so converted to printing. It's expensive but looks clearer and don't sli......p

  • @joemaldonado3
    @joemaldonado3 ปีที่แล้ว

    greetings from the USA! great quality work !!! AGREED: professional work only in all cases! no amateurs!

  • @neilwilletts2392
    @neilwilletts2392 ปีที่แล้ว

    Pleasure to see the pride you take in your work, you are a credit to your trade

  • @AndyK.1
    @AndyK.1 3 ปีที่แล้ว +19

    Tools of the day. Pencil. 😆. I know you need a marker too and you can’t carry both in the Tesla and Cory has the pencil booked out today.

  • @kyester123
    @kyester123 3 ปีที่แล้ว +40

    I was always taught to cut trunking lid after and not at the same time as the trunking itself. You can get a nicer and more precise finish then.

    • @pault4793
      @pault4793 3 ปีที่แล้ว +10

      your right , never cut trunking with the lid on. Normally put lid on just beneath the cut line to make the trunking rigid while you cut, then take it off , fit trunking and cut lid to suit .

    • @artisanelectrics
      @artisanelectrics  3 ปีที่แล้ว +12

      I just find it’s more rigid if you leave the lid on it doesn’t flap around so much when you’re cutting it so makes it easier to get a straight cut

    • @tommymack3210
      @tommymack3210 3 ปีที่แล้ว

      @Ellis The DJ just find something that works for you 👍👍

    • @philgreen5ges
      @philgreen5ges 2 ปีที่แล้ว

      I’ve always cut plastic and steel lid at the end not at the same time. I see engineers at work cutting trunking with lid on with a grinder., mmm not for me then eh, we all work differently
      I tend cut trunking over 75mm with a jig saw anyway
      Keep up the good work

  • @TradifyHQ
    @TradifyHQ 2 ปีที่แล้ว

    Incredible work Jordan! Great to see the thought behind the process. 🙌

  • @laurencebugeja4160
    @laurencebugeja4160 3 ปีที่แล้ว

    A nice job you have done.For termination of multiplexes cable I use ferrules to prevent any copper strand folds back and when I fix trunking to the consumer I usually cut the dimension of the trunking by a jigsaw which it fits neatly and for marking I always use pencil and I like to put some masking tape were I need to make the marking. I also do marking of each circuits as you have done before connecting so if I have to isolated any particular circuit I will find it immediately. Bye and well done again.

  • @desmondbradley7916
    @desmondbradley7916 3 ปีที่แล้ว +8

    Always good to see your vids! Some useful tips. If you have to remove the cut out you should remove the fuse and reinsert the carrier, otherwise you have exposed a hole which has a permanently live feed in it. Mentioned this before, but cut out removal by anyone other than the DNO, electricity supplier or the Fire Brigade is not permitted. I have been on the receiving end of an appearance of Western Power on a job when I did this with a smart meter. The loss of power to the meter sets an alert off and the DNO is expected to attend to find out as its a loss of power to the property. If they are busy on other work they won’t rush out, but they can, and do attend.

    • @jam99
      @jam99 2 ปีที่แล้ว +7

      Everyone knows that any extra time waiting for DNO is extra cost to customer. What is the solution? DNOs should be rolling out the fitting of isolators in all properties. Forget rolling out smart meters; get the sodding isolators fitted. It is in the interest of safety, the consumer and the trade.

    • @ali87468
      @ali87468 2 ปีที่แล้ว

      @@jam99 Funerals aren’t cheaper either !

  • @kevinhart1167
    @kevinhart1167 3 ปีที่แล้ว +4

    Its quite handy to stick a blank piece of paper above or below the board while doing the change over so you can temporarily mark up the circuits then transfer the information onto the new board at the end.

  • @geoffh1055
    @geoffh1055 ปีที่แล้ว

    Excellent as always - Totally absorbing and informatve. A really well delivered video as per normal. Really nice to see care, quality and craftsmanship. I do agree with the previous comment on the isolator

  • @iknowmyfootball3901
    @iknowmyfootball3901 3 ปีที่แล้ว

    Jordan congrats on the 50000 subscribers thoroughly deserved

  • @tww5719
    @tww5719 3 ปีที่แล้ว +5

    Never thought there was a left and right to a ring,learn something every day 👍

    • @artisanelectrics
      @artisanelectrics  3 ปีที่แล้ว +6

      There isn’t really but it’s just a way of showing there are two different legs

    • @kristianhumphreys7984
      @kristianhumphreys7984 3 ปีที่แล้ว

      @@artisanelectrics whilst doing the continuity of ring circuits. Does it matter which live and which neutral are joined together?? Or as long as they are on different legs to the ring its fine?

    • @artisanelectrics
      @artisanelectrics  3 ปีที่แล้ว

      @@kristianhumphreys7984 Yeah as long as they are on different legs of the ring then its fine, but if you are doing the cross connection R1&R2 test then you do need to choose opposite sides of the ring

  • @derekrichardson9138
    @derekrichardson9138 3 ปีที่แล้ว +57

    Tool of the day should be you you say about safe isolation but then remove the main fuse an leave it exposed with the main tails flapping about an the bear earth that your touching an then to top it off you have your knee resting on the open cutout if you trim a cable an it lands on you knee an happens to go in the cut out thats you gone I have a red fuse holder that I put in an labelled up as no fuse in this carrier stay safe an keep up the good videos mate

    • @simonbates9779
      @simonbates9779 3 ปีที่แล้ว +11

      My Dad always said “If you have nothing nice to say, don’t say anything at all” what’s your channel so we can watch how to do it perfectly

    • @SurvivalManagementGroup
      @SurvivalManagementGroup 2 ปีที่แล้ว +3

      Mate... Full stops ✋️
      Nearly had a stroke reading that.

  • @Mr-Chris
    @Mr-Chris 2 ปีที่แล้ว

    I don't know how I stubbled on to a UK video, but nice job. I'm from the US and I just had my consumer unit changed what we call (Main electrical panel) The thing is huge. I went from a 100 AMP panel to 200 AMPs. It required my electrician to drive two new ground rods in my yard and run another ground wire to my water meter. I have now room for 40 breakers and 80 circuits.

  • @seanhanley6244
    @seanhanley6244 2 ปีที่แล้ว

    Aesthetically pleasing to watch. Love the finished result.

  • @boli2746
    @boli2746 3 ปีที่แล้ว +18

    This is brings back memories of me doing my own consumer box! Sadly I had to add two more MCBs and one RCBOs at later date so my nice neat wires got a bit messy :/
    Yes, full DIY, but reserched like crazy and got it certified by a qualified electrician (who actually complimented me on my work :) )

  • @Liberator975
    @Liberator975 3 ปีที่แล้ว +8

    I usually take that in the bottom below the two larger tails 😂😂

  • @davidirvine6035
    @davidirvine6035 3 ปีที่แล้ว +1

    Keep the videos coming Jordan, enjoy them a lot.

  • @assifkhan3803
    @assifkhan3803 ปีที่แล้ว

    Wow.thanks for so many good tips .I am doingy second consumer unit and I be watched many units being fitted .the more videos I watch the more experience I get .you are really good bro..

  • @leeburnside735
    @leeburnside735 3 ปีที่แล้ว +3

    Correct me if I’m wrong but was there not a gap at edges of trunking leaving a hole going into DB ipx2 ??

  • @jamest5149
    @jamest5149 3 ปีที่แล้ว +5

    “I usually take that in the bottom” 😵‍💫😂

  • @ZahidAli-xp5rv
    @ZahidAli-xp5rv 3 ปีที่แล้ว

    You are a legend, I wish get my work experience from you, its far I live up north in Manchester....Thank you so much to make it so easy to understand...! Also you are a very good teacher...!

  • @pauldavies1693
    @pauldavies1693 ปีที่แล้ว

    Hi, mate. Thank you for that excellent video. I prefer you to all of the other sparks, you never leave me with any questions, you go through every detail very well and I am going to follow your example through out my career. I am about to start college this year and you are a massive help to get me used to all the jargon. I'm going to save all of your others now. Thank you again. Take care.

  • @peterc4450
    @peterc4450 ปีที่แล้ว

    Long retired electrician, like that tool you had for stripping the tails, used to use a cable cropper to score the insulation or knife.

  • @brightside0970
    @brightside0970 3 ปีที่แล้ว +45

    Nice video! I don’t mind doing consumer units. Just a thought to fit a isolator instead on Henley blocks just incase the power needs cutting saves pulling the main fuse

    • @ColinRichardson
      @ColinRichardson 3 ปีที่แล้ว

      Does it matter if the isolator goes pre or post meter?

    • @brightside0970
      @brightside0970 3 ปีที่แล้ว +5

      @@ColinRichardson do it after the meter because your not allowed to touch any that. Not your property. Plus if their is a fault with the meter you can isolate the consumer unit. Which I’ve had to because of it

    • @ColinRichardson
      @ColinRichardson 3 ปีที่แล้ว

      @@brightside0970 That is what I thought, and obviously a direct replacement for the henley block.
      I have seen isolators BEFORE the meter, so I am guessing those were fitted by grid operators.
      I just wanted to confirm

    • @williammartinculleton7523
      @williammartinculleton7523 3 ปีที่แล้ว +4

      Yes indeed, much better to install a isolator rather than a Henley Block far more useful & practical, not withstand, it was well done, obviously got a really good price for it, therefore no need to rush. Well done " reassuringly expensive " 😂😂😂

    • @TheChipmunk2008
      @TheChipmunk2008 3 ปีที่แล้ว +2

      @@ColinRichardson Isolators before the meter are... not normal practice...electrically it's fine, but it really makes electricity abstraction childsplay, and causes smart meters to send alerts. The ones you've seen are likely mistakes by smart meter installers, who sometimes are really well trained, professional people with years of experience, and are sometimes not gonna give a chimp a run for their money on an iq test. There is no middle ground

  • @effervescence5664
    @effervescence5664 3 ปีที่แล้ว +20

    Personally I tend to cut the meter seal and terminate them into the meter unless they've provided blocks already. Two reasons first if they're 16mm tails at the meter they should be upgraded if your main switch is 100A. Second because the customer is technically responsible for everything after the meter that includes the tails to the consumer unit which you're essentially becoming responsible as the engineer changing the unit and carrying out the testing and certification. As long as you carry your own seals to reseal and keep records of, it's not really an issue of tampering it's an issue of safety and responsible workmanship.
    Great video and quality workmanship as always. As a side note the tail clamp is only good for top/bottom entry if you come in from the side it's a pain in the butt and you find yourself having to strip the outer tail sheath to make the turn.

    • @UberAlphaSirus
      @UberAlphaSirus 3 ปีที่แล้ว +7

      Yup, and if 3 foot of non flexi tails have been flapping around all day from the meter terminals, I would like to know they are still tight. Should have cut them of and put in a cutoff or henley before taking the board off IMPO.

    • @jonanders76
      @jonanders76 3 ปีที่แล้ว +2

      Just out of interest, why does the main switch rating have anything to do with the ccc of the tails?
      Using 16mm is fine up to 87A clipped direct, and with most household main fuses rated at 60A - 80A, why try and stuff 25mm into the woefully inadequate and awfully shallow cage clamps of a modern (not fit for purpose) (must be enclosed in non combustible material) (terminal screws made of soft putty like material) main switch. Having said that, at least the 25mm flexible tails seem to hold a little better (shame about the lack of tunnel terminals and two terminal screws)

    • @UberAlphaSirus
      @UberAlphaSirus 3 ปีที่แล้ว +1

      @@jonanders76 Your gonna have to clarify the queastion/s.

    • @havoctrousers
      @havoctrousers 3 ปีที่แล้ว +1

      @@jonanders76 I think he meant the rating of the supplier's fuse rather than the main switch. If you have a 100A fuse, you definitely want 25mm tails. Otherwise the 16s are probably fine as I think they're good for about 87A

    • @geraldelwood9660
      @geraldelwood9660 2 ปีที่แล้ว

      Jon and Robin are correct. Min size of tails is governed by the main cut-out fuse. Obvious really - this fuse is the only protection for the tails. Nothing to do with the Max capacity of equipment downstream of the tails.
      Some electricity suppliers, such as Octopus, require engineers to upgrade tails to 25mm even for 80A fuses, but just playing safe. And a point to Mr Bubbly above :) cutting the seals on the meter is NOT acceptable and is an order of magnitude above pulling fuses (which we all do for justifiable safety reasons) In case you are unaware, the seals carry a unique and traceable identifier number when fitted by the approved meter engineer.

  • @lewisdraper2858
    @lewisdraper2858 3 ปีที่แล้ว

    18.04 'line to the left of me, neutrals to my right ' 🎶🤣

  • @davemitchell8756
    @davemitchell8756 3 ปีที่แล้ว

    Great to see such a neat job and you taking pride in your work 👍

  • @AfifAhmad
    @AfifAhmad 3 ปีที่แล้ว +8

    I'll happily organise your box, however I'm in Australia lol

    • @t33bee8
      @t33bee8 2 ปีที่แล้ว

      Interesting proposal

  • @curtismal1726
    @curtismal1726 3 ปีที่แล้ว +30

    Looks neat only thing I would do different would be to fit a wylex isolator

    • @luluboxingtv2880
      @luluboxingtv2880 3 ปีที่แล้ว +3

      Agreed

    • @callumsimpson7483
      @callumsimpson7483 3 ปีที่แล้ว +3

      Yes definitely if your pulling the main fuse you might as well fit a two pole isolator. Only takes 5 min

    • @robtyler9564
      @robtyler9564 3 ปีที่แล้ว +2

      Thought the same myself

    • @eric4709
      @eric4709 2 ปีที่แล้ว +1

      Absolutely !! Why NOT fit an isolator ???? - Makes PERFECT SENSE!!

  • @thewoodsmanstickmakero.c.w7862
    @thewoodsmanstickmakero.c.w7862 ปีที่แล้ว

    Lovely job pal and great video.

  • @adrianupnorth
    @adrianupnorth 3 ปีที่แล้ว +2

    Good to see quality work, I come across so many new boards that are thrown in. I probably would have fitted an isolater instead of a Henley as brightside mentioned. I just hate pulling the main fuse, does anyone still phone the DNO to reapply the seals?

  • @AGRElectrics
    @AGRElectrics 3 ปีที่แล้ว +23

    "I usually take that in the bottom" 22:48 XD

    • @dannydobson2675
      @dannydobson2675 3 ปีที่แล้ว +5

      Now that’s a game changer!!

    • @bryancarruthers1121
      @bryancarruthers1121 3 ปีที่แล้ว +3

      Painful

    • @AGRElectrics
      @AGRElectrics 3 ปีที่แล้ว +4

      @@bryancarruthers1121 thank god its a flexi tail!

    • @knightstemplar8379
      @knightstemplar8379 3 ปีที่แล้ว +3

      I picked up on that also, and thought to myself, that was childish, but then read your comment and realised I'm not alone..😁

    • @leonplatt9723
      @leonplatt9723 3 ปีที่แล้ว +1

      Not only does he take his 16mm cpc “in the bottom” but, he likes to “take the largest circuits first”. 😏

  • @markpayne4432
    @markpayne4432 3 ปีที่แล้ว +66

    Why didn't you fit an isolator switch instead of Henley blocks ...safer and easier for the next sparks

    • @acelectricalsecurity
      @acelectricalsecurity 3 ปีที่แล้ว +7

      Must admit that went through my mind as well👍

    • @GregMoseley
      @GregMoseley 3 ปีที่แล้ว +4

      I came on to ask exactly the same!

    • @SqwarkParrotSpittingFeathers
      @SqwarkParrotSpittingFeathers 3 ปีที่แล้ว +5

      Me too, I was expecting it. Especially as he pulled the main fuse, knowing the next guy was going to have to do same. Still.

    • @seandunne2673
      @seandunne2673 3 ปีที่แล้ว +10

      I may be wrong and correct me if I am wrong but I thought you have to get the DNO out to fit an isolator switch 🤷🏻‍♂️

    • @kloddi25
      @kloddi25 3 ปีที่แล้ว +9

      Would have been another hour extra = 96£ 😃

  • @machcncsystems
    @machcncsystems 3 ปีที่แล้ว

    In Australia "Down Under" we only use Milwaukee Inksall, because they work and you never need to throw them away. Also I tried Tradify and was very happy, however It didn't offer GPS tracking to customers or Post Invoices. I know that the mail is dying however some elderly customers prefer a paper invoice and we normally send 20 through the post a month.

  • @terrybutler1231
    @terrybutler1231 10 หลายเดือนก่อน +2

    Customer with more money than sense - we need more like that! Yippee 😂

  • @adeytecnic
    @adeytecnic 3 ปีที่แล้ว +4

    My DNO (Western Power) told me I'd face a 10 grand fine if I pulled a client's fuse! They said if there is a smart meter fitted, it would inform them. Now I always have to wait for the client to arrange with their energy provider to install a double pole isolater.

    • @artisanelectrics
      @artisanelectrics  3 ปีที่แล้ว

      There’s a petition about this going round at the moment as it’s stupid that they do that.

    • @simonto9397
      @simonto9397 3 ปีที่แล้ว

      So what happens after to the fuse as you have cut the wire? Do you crimp another one on?

  • @stevecraft00
    @stevecraft00 3 ปีที่แล้ว +6

    Great job. As somebody who does a lot of testing, i noticed no mixed colours label and no rcd label on the front (that i could see). I hope they were placed before you left! You seem to be getting a bit of a pasting here for the henley block. I do tend to agree tbh, an isolator would have been far more useful an addition than a henley. I dont believe in adding connections in large cables like that without a good purpose. The henley block serves no purpose. I love to get to grips with a good board change though, im looking forward to doing my mums when i qualify. It was butchered and thrown at the wall about 20 years ago by a buffoon, so anything i do will be an improvement!

    • @marcusstonham
      @marcusstonham 3 ปีที่แล้ว

      Adding a henley block creates no more issue than if an isolator had been fitted. Granted an isolator would have been a better choice, even by Jordan's admission, however there is still the same amount of connections made. Not everyone carries 100a tail isolators around.

    • @stevecraft00
      @stevecraft00 3 ปีที่แล้ว

      @@marcusstonham my point was more that an isolator would have a function here. The henley never will, its a rented house and the board has plenty of spare ways, there isnt going to be another board fitted.

    • @marcusstonham
      @marcusstonham 3 ปีที่แล้ว

      @@stevecraft00 but it doesn't actually matter. Isolator better yes, but henley block isn't an issue and doesn't create an issue

    • @stuartrhoades4306
      @stuartrhoades4306 3 ปีที่แล้ว

      @@marcusstonham personally I'd have just taken the new tails straight into the meter.

    • @ali87468
      @ali87468 2 ปีที่แล้ว

      Make sure you get an isolator fitted first .

  • @KarlMcClelland
    @KarlMcClelland 3 ปีที่แล้ว

    Brilliant video. Love your attention to perfection. Much love from Belfast

  • @g.williamswilliams8442
    @g.williamswilliams8442 2 ปีที่แล้ว

    Really good work mate... Excellent result...
    Just be careful with all that excess sub circuit cpcs that one of them doesn't accidentally lodge in the incoming live in the cut out, and give you a pisser on the face from its returning pair...
    Always a joy to watch...
    Excellent video

  • @michaelcoleman5229
    @michaelcoleman5229 3 ปีที่แล้ว +12

    Personally I’d fit a Wylex 100A DPI over a Henley block but each to their own.
    On a serious note have you ever been bollocked for cutting the seals and pulling the main fuse?

    • @artisanelectrics
      @artisanelectrics  3 ปีที่แล้ว +4

      Thanks and no never

    • @michaelcoleman5229
      @michaelcoleman5229 3 ปีที่แล้ว +1

      @@artisanelectrics 👍🏻

    • @G8TIC
      @G8TIC 3 ปีที่แล้ว

      REC2 every time

    • @MrElliott1979
      @MrElliott1979 3 ปีที่แล้ว +1

      You will know about it if you get a flashback, just don't pull it under load.

  • @peterc3228
    @peterc3228 3 ปีที่แล้ว +3

    Hi Jordan, congratulations on 50k subscribers milestone. Very well deserved as you always have good quality content on your channel. Also congratulations on getting Hilti as a sponsor, that wall chaser and dust extractor is awesome piece of kit! by one of the ultimate tool companies. Keep up the good work. Stay safe guys. Pete 👍

  • @MegaPaul57
    @MegaPaul57 3 ปีที่แล้ว

    Thanks Jordan your videos produce a lot of comments which is great and you obviously have a lot of veiwers

  • @elliotcourt580
    @elliotcourt580 2 ปีที่แล้ว

    Lovely job mate. Very professional and full of great tips. I must agree with the masses here though....absolutely killed me that you fitted a Henley block over an isolator. Oh well, smashing end result!

  • @chrisglover1978
    @chrisglover1978 3 ปีที่แล้ว +3

    Why fit a Henley Block instead of an Isolator switch?

  • @jamessparks7962
    @jamessparks7962 3 ปีที่แล้ว +5

    It still really annoys me that smart meter installers still don’t provide means of isolation, they only cost £12.99 from Toolstation. It’s for that reason that I cut all their seals off, replace everything with new tails, and install an isolator as standard now. Rant over, a very neat job Jordan, love your standards and it’s nice when a customer gives you the time to do a proper job.

    • @artisanelectrics
      @artisanelectrics  3 ปีที่แล้ว +1

      Great idea I might start doing the same!

    • @MrElliott1979
      @MrElliott1979 3 ปีที่แล้ว

      Agree 25mm future proofing especially now EV installs are more frequent, how did you know that the cutout fuse carrier contained a 100 amp fuse ? The sticker on the outside just identifies that the cutout is suitable upto 100amps some meter engineers use independent stickers, next time open up the carrier to see what's inside.

    • @richardfld
      @richardfld 2 ปีที่แล้ว

      Economics. Theres 16 million smart meters installed. An isolator might 'only' cost 12.99 but times that by 16 million...
      Plus cost of new cables etc.
      Given that suppliers have to keep costs to a mimimum due to price cap and cost of wholesale energy how do you propose they fund tens, or even hundreds of millions of pounds spent on isolators?

    • @jameshorspool5054
      @jameshorspool5054 2 ปีที่แล้ว +1

      @@richardfld yea poor energy company's must be skint, let one man band Joe bloggs pay for it yea, with the rising cost of electricity at the moment they must be hard up....

    • @tonyde-leon5846
      @tonyde-leon5846 ปีที่แล้ว

      Isn't it illegal to cut the seals?I'm sure someone get arrested and fined a few years back for leaving a cut out not sealed? personally, I would seal the cutout up after as it's the right height for a toddler

  • @munafmufc01
    @munafmufc01 3 ปีที่แล้ว

    Once again excellent vid.. Thanks Jordan

  • @hussmortada
    @hussmortada ปีที่แล้ว

    Very helpful video, I certainly learnt a couple of trick. Work of art consumer unit - bravo👏

  • @oyleyhands1332
    @oyleyhands1332 3 ปีที่แล้ว +13

    I would be surprised if those cables were LSF as some manufacturers supplied twin and earth in white.

    • @cumberland1234
      @cumberland1234 3 ปีที่แล้ว +2

      I think you’re right, iirc they only brought it in when they changed the wiring colours so old red/black with white sheath could be pvc

    • @artisanelectrics
      @artisanelectrics  3 ปีที่แล้ว +3

      Yeah I think you’re right too as they were pretty easy to strip and LSF is usually quite tough

    • @izalman
      @izalman 3 ปีที่แล้ว

      White sheath cable was used on surface mount in visible / decorative installations . Looked less intrusive than the grey. You could get white t&e clips too.

  • @bryceonyoutube
    @bryceonyoutube 3 ปีที่แล้ว +24

    Could I just ask why did you not install a main isolator instead of a connector block?

    • @electricery
      @electricery 3 ปีที่แล้ว +6

      He says the customer wants the best and then he ignores the basics.

    • @russellbosley5988
      @russellbosley5988 3 ปีที่แล้ว +2

      I would guess the DNO will fit one when they come and re-seal the fuse?

    • @electricery
      @electricery 3 ปีที่แล้ว +5

      @@russellbosley5988 ha ha, that's a good one

    • @ashhowey
      @ashhowey 3 ปีที่แล้ว +2

      @@electricery and it’s all bang up to date but leaves red and black tails between the meter and the block 🤣👍

    • @electricalstuff259
      @electricalstuff259 3 ปีที่แล้ว +1

      @@ashhowey And if i remember rightly he's charging like 500 quid a day !

  • @kasualskeptik2584
    @kasualskeptik2584 3 ปีที่แล้ว +1

    Job well done Jordan..!
    Jordan said "I actually take that in the bottom" giggle...

  • @edglue6138
    @edglue6138 2 ปีที่แล้ว

    Very informative. Cheers for taking the time.

  • @steveb1856
    @steveb1856 3 ปีที่แล้ว +11

    I’d have asked to have the CU at eye level if it was mine, especially with that lid that only goes part way up.

    • @TheChipmunk2008
      @TheChipmunk2008 3 ปีที่แล้ว

      yeah didn't like that 'feature'. Not typical for Hager... they're usually ahead of the curve on design. Maybe they were only considering new builds, where the CU has to be high up, rather than retrofits

  • @steveaddie3461
    @steveaddie3461 3 ปีที่แล้ว +5

    Was a bit concerned about the main incomer fuse holder not put in, and you stripping cables near it BOOOOOOOM

    • @electricery
      @electricery 3 ปีที่แล้ว +1

      Totally irresponsible, demonstrates his level of skill and safety consciousness

    • @andytap560
      @andytap560 3 ปีที่แล้ว +1

      I tape over it absolute minimum.

    • @ali87468
      @ali87468 2 ปีที่แล้ว

      @@electricery Dangerous , in the extreme ! Amazed at how many people , don’t realise how dangerous or illegal what this guy is doing . These videos are clearly an ego trip !

    • @ali87468
      @ali87468 2 ปีที่แล้ว

      @@andytap560 should never have been removed, end of .

    • @andytap560
      @andytap560 2 ปีที่แล้ว

      @@ali87468 haha ok mate.

  • @rady20092009
    @rady20092009 3 ปีที่แล้ว

    Just thought I'd put it out there that I'm just a DIY electrician and I changed a full consumer unit and rewired and on of the people living with me tried grassing me up to the electricity board and they sent out 2 qualified electricians to see what the complaint was which they did say I shouldn't have attempted this, especially on a 5 bedroom house but they couldn't fail it as it was all good work they said 🤣 they passed it for 5 years and it still works now 10 years later 🙂 never attempted any since but it was great practice 😁 oh and love the neat finish, such a great job I'd definitely call someone like this in future 👍

  • @jerrybenn3583
    @jerrybenn3583 3 ปีที่แล้ว

    Another great video Jordan, good to see you back in the tools .

  • @oyleyhands1332
    @oyleyhands1332 3 ปีที่แล้ว +6

    A DP 100amp meter switch is only several pound more than a DP 100 'Henley block' any reason not to fit ? irrespective of what switching you have in the consumer unit.
    I sort of cringe when I see an open cut out without tape over it or refitted without the fuse as I'm just waiting to see a cable fall in there..especially a a bare earth one...ouch !

    • @AS19283
      @AS19283 3 ปีที่แล้ว

      Not fussed about the isolated but yep, get a tiny bit of tape on their. Only takes a random cable to swing down and it’ll get interesting. I think their work is good from what’s shown but a little bit of tape can save you!

  • @oyleyhands1332
    @oyleyhands1332 3 ปีที่แล้ว +5

    I was wondering why you were concerned about the cable lengths when you could raise the board a bit to compensate..then, you did do.
    And those 'big' hacksaw take up so much more room... 😁😁😁 one 'big' hacksaw between two sparks? at your rates 😁😁😁

  • @marine8258
    @marine8258 3 ปีที่แล้ว +1

    Loving the videos and keep up the awesome work. It would be nice to see the certificate filling side to one of your jobs in the future 👍👍

  • @adamwiseman1906
    @adamwiseman1906 11 หลายเดือนก่อน

    Brilliant job and very well explained throughout 👍

  • @GregMoseley
    @GregMoseley 3 ปีที่แล้ว +20

    22:48 🤣🤣 an unfortunate pause at the end too

    • @TevjaWeston
      @TevjaWeston 3 ปีที่แล้ว +3

      25:11 too.....

    • @jonny7491
      @jonny7491 3 ปีที่แล้ว +1

      Wondered what on earth you was on about had to rewind. Classic

  • @petermichaelgreen
    @petermichaelgreen 3 ปีที่แล้ว +11

    It's only T&E with harmonized core colors where white sheath indicates LSF. In the red/black days you could get regular PVC T&E with a white sheath. In some parts of the country white sheath tends to indicate DIY as the DIY sheds carried white while the wholesalers only carried grey.

    • @UberAlphaSirus
      @UberAlphaSirus 3 ปีที่แล้ว

      Didn't bother to look at the markings did he.

    • @acelectricalsecurity
      @acelectricalsecurity 3 ปีที่แล้ว +1

      Yeah B&Q special, there's no way you would strip lsf with a striping tool like that

  • @simonclements
    @simonclements 3 ปีที่แล้ว

    What a really neat and professional job,well done👍

  • @iangregoryhome
    @iangregoryhome 3 ปีที่แล้ว +1

    Excellent, I'm a fibre engineer and take pride in my work also.

  • @dc-sd3gd
    @dc-sd3gd 3 ปีที่แล้ว +24

    I always renove the main fuse and put the fuse holder back on the cutout, only because knowing my luck id fall and touch the mains🤣

    • @timalden4994
      @timalden4994 3 ปีที่แล้ว +3

      Agreed much. I was wincing a bit as J pulled the tails out of the CU and they were bouncing around a bit.

    • @artisanelectrics
      @artisanelectrics  3 ปีที่แล้ว +7

      Yeah I did do that just didn’t show it on the video

    • @tobysherring1369
      @tobysherring1369 3 ปีที่แล้ว +5

      It's not in there at 27.39...

    • @artisanelectrics
      @artisanelectrics  3 ปีที่แล้ว +6

      Yeah initially I forgot but you can see it later on. Usually I use these insulating plugs that a DNO guy sent me but Cory has them in the van.

    • @Marco-mg9tv
      @Marco-mg9tv 3 ปีที่แล้ว +4

      @@artisanelectrics or a piece of cardboard torn off the new CU box wedged in does the job 😉

  • @jacka5994
    @jacka5994 3 ปีที่แล้ว +4

    If you were willing to cut the seals on the c/o why not just cut the one on the meter too it’s the same “offence” (in my opinion if it’s the only safe way of isolation I completely agree with cutting the seals btw) that way could of just ran new tails all the way into the metre no need for un necessary terminations/weak points?

    • @jam99
      @jam99 2 ปีที่แล้ว +1

      Because he doesn't have to. He only pulls the fuse because it is the only way to work safely without calling out the DNO. Also, maybe he has a sealing kit for the fuse but not for the meter... some sparks do.

    • @jacka5994
      @jacka5994 2 ปีที่แล้ว +1

      @@jam99 your not allowed to cut any of the seals and remove the DNO’s fuse at all regardless of the circumstances. But all I was saying is it’s black or white have you cut seals or not YES cut 1 or cut 3 either way you’ve broken the law may as well do the full job 😂 and what sealing pliers would only crimp a seal on a c/o and not on the meter they’re the exact same seals and wires

    • @jam99
      @jam99 2 ปีที่แล้ว +1

      @@jacka5994 a) Why double the chances of getting into trouble? A supplier won't be bothered with what is to the left of the henley block and the DNO won't be bothered with what is to the right of the henley block. b) When a judge awards a penalty in a court of law, the penalty is usually based on the severity of the action. Double the offense can increase the penalty. c) Sealing pliers can fit branded seals.

  • @Jetstreamsky
    @Jetstreamsky 2 ปีที่แล้ว +1

    Interesting change ostensibly for lighting circuit protection, I once stayed at a rental cottage in Devon and was unpacking when
    I heard a tremendous bang followed by the sound of glass shards falling. In the next room my girlfriend had attempted to change a lightbulb for some reason in the ceiling light and unknown to her (being Canadian), she was screwing in the lightbulb like a threaded type common in North America into the bayonet fitting to a point it broke and shorted the live wiring out.

  • @sobretiempo68
    @sobretiempo68 ปีที่แล้ว

    Bloody entertaining and instructive!!! New subscriber… excellent cameraman, very supportive and focused to create this content.

  • @artisanelectrics
    @artisanelectrics  3 ปีที่แล้ว +15

    Todays Video Sponsor:
    Tradify - Get 50% Off your first 3 months with Tradify using the discount code "ARTISAN" and this link: bit.ly/3qWjRkU

    • @DerekHundik
      @DerekHundik 3 ปีที่แล้ว +1

      Hey Could you link me to that seal 15:55

    • @artisanelectrics
      @artisanelectrics  3 ปีที่แล้ว +2

      @@DerekHundik amzn.to/2P7LlXb

    • @valhallaelectrical6835
      @valhallaelectrical6835 3 ปีที่แล้ว +1

      Was just about to ask the same 👍

    • @valhallaelectrical6835
      @valhallaelectrical6835 3 ปีที่แล้ว

      Update. This is one of the best tips going. Used it. Really pleased with the finish on the CU... nice one dude

    • @artisanelectrics
      @artisanelectrics  3 ปีที่แล้ว +1

      Awesome thanks

  • @donzotv1667
    @donzotv1667 3 ปีที่แล้ว +3

    How did Corey confirm CPC continuity on the ring mains if they were twisted? you said he did an EICR? surely that's something you would check

  • @georgeokeeffe3284
    @georgeokeeffe3284 3 ปีที่แล้ว +1

    Amazing work 👌🏻👏🏻👏🏻👏🏻👏🏻👏🏻 I’m not an electrician but I really enjoy your vids 🤙🏻

  • @georgedaville4662
    @georgedaville4662 2 ปีที่แล้ว

    Good to see people like you who are proud of their trade. Pleasure to watch you work.👍😎

  • @JamesQ2011
    @JamesQ2011 3 ปีที่แล้ว +6

    Have you ever seen a flashover on a cutout? The disconnect time is 15 seconds? To the ring RMU (I think) anyway, it's safe to say it's extremely dangerous to leave a cutout with no protection. I can't see anything in this video? (Correct me if I'm wrong) A board change requires lots of manipulation of bare copper. Lots of debris. You can already see the cutout is covered in brick dust.
    If the DNO allows you to remove the main fuse from the cutout you should use proper screening of the live parts inside once the fuse is removed to prevent anything coming into contact with them. You can easily kill yourself, or cause very severe burns! Do not remove the cut out fuse unless you have screening available, and use the specific PPE that the DNO requires.

    • @ronimure1649
      @ronimure1649 3 ปีที่แล้ว +2

      Avoid sprinkling the sniped off ends of the incoming tails in to the new board

    • @DEADB33F
      @DEADB33F 2 ปีที่แล้ว +1

      @@ronimure1649 Heh, I'm not a spark but even I noticed that.

  • @Spark101.
    @Spark101. 3 ปีที่แล้ว +4

    Jordan.....I swear you’re on a wind up. Lol
    Most expensive firm I know......and you have one ‘ big hacksaw’ between you all! Lol. Come on mate! Do you sign it out to the lads when they need it? Lol!

    • @artisanelectrics
      @artisanelectrics  3 ปีที่แล้ว +2

      Haha yeah unfortunately we’re in transition as Cory has my van and all my tools I’m only working on the tools one day a week at the moment so can’t really justify buying a van for myself, so I’m working out of the Tesla and just grabbing the tools I need when I need them. Prob gonna have to get myself a little van soon tho.

    • @Spark101.
      @Spark101. 3 ปีที่แล้ว +1

      @@artisanelectrics Defo....get one. You need it. But why hasn’t Corey got a big hacksaw?

    • @artisanelectrics
      @artisanelectrics  3 ปีที่แล้ว +1

      @@Spark101. he does have my one but I didn’t borrow it back

    • @Spark101.
      @Spark101. 3 ปีที่แล้ว +2

      @@artisanelectrics Tell him to buy his own! lol.
      It’s not the end of the world though! I just thought it funny you guys sharing a hacksaw.
      To be fair, we have the same situation. The company pencil! No matter how many I buy, we always only have the one! 😂

    • @AndyK.1
      @AndyK.1 3 ปีที่แล้ว +1

      Tis funny. It’s probably oscars toolkit.

  • @yorkshireoz3583
    @yorkshireoz3583 3 ปีที่แล้ว +1

    50K well deserved mate

  • @wax83
    @wax83 ปีที่แล้ว

    Fantastic job! You are very good guys!

  • @kyester123
    @kyester123 3 ปีที่แล้ว +9

    These are interesting videos to watch after work, as always with any of the TH-cam sparks, but my concern with these style of videos is that the amount of them out there now on how to fit a CU/ DB is crazy,. Especially when anyone without the relevant qualifications can just buy the bits and pieces from screwfix, then have a go themselves at fitting a CU/ DB following a TH-cam video. Note to anyone unqualified doing what I've just mentioned, just because something works doesn't mean it's safe.

    • @lewisdraper2858
      @lewisdraper2858 3 ปีที่แล้ว +2

      You could say that about anything technical on the internet

  • @LoudAsFuckk
    @LoudAsFuckk 3 ปีที่แล้ว +4

    Whoever mixed this audio needs to reassess their life. Super quiet talking portion and then BANG fucking full chat tunes

  • @DavePawson
    @DavePawson ปีที่แล้ว

    Safe, functional and neat.
    A joy for future jobs!