How I Diagnose a Bad TXV | 👉 Thermostatic Expansion Valve 🦊

แชร์
ฝัง
  • เผยแพร่เมื่อ 7 ก.ค. 2024
  • In this HVAC training video, I will describe how I diagnose a bad TXV. A thermostatic expansion valve meters the flow of refrigerant into the evaporator coil.
    #thermostaticexpansionvalve #hvactrainingvideos
    HERE IS THE LINK FOR THE FLOW CHART 👇⬇
    1drv.ms/u/s!AnT17rJhe6DVg9Jjd...
    If the thermal expansion valve is bad the evaporator coil freezing might happen, which would reduce airflow to the point where no more air would blow into the house. It can be frustrating not knowing what's going on with your TEV or thermal expansion valve as some people call it. If you don't know the symptoms of a bad TXV, you might end up just making things worse for the homeowner. If you need TXV troubleshooting tips, don't be shy. I can get you through this! Figuring out your subcool and superheat will help you diagnose a bad TXV. The metering device on an evaporator coil could be a fixed orifice or a TXV. So, good luck with this video and the TXV explained.
    🦊Please visit our website @ www.foxfamilyhvac.com
    👉If you'd like to book an appointment with Fox Family Heating and Air in Sacramento, El Dorado, or Placer County, CA book.housecallpro.com/book/Fo...
    **********************************************************************************
    Visit us on our social media pages:
    FLOW CHART LINK:
    📘 Facebook @ / foxfamilyheatingaircon...
    👦 LinkedIn @ / greg-fox-46ab48110
    💻 Twitter @ / foxfamilyhvac
    👨‍🔧Please help our channel produce more quality content for those interested in our industry.
    SUPPORT HVAC and the BLUE COLLAR TRADES!
    / foxfamily
    00:00 Intro
    1:16 What's happening inside the evaporator coil?
    3:13 Before diagnosing a bad TXV, Check the basics
    4:52 Superheat
    5:42 Subcool
    6:10 Communicating refrigerant pressures to each other
    6:36 What can we tell when we check superheat and subcool?
    7:08 It’s a Bad TXV. What Can I Do Now?
  • ภาพยนตร์และแอนิเมชัน

ความคิดเห็น • 57

  • @khoolexairconditioning868
    @khoolexairconditioning868 2 ปีที่แล้ว +10

    This video is as good as it gets, very informational and to the point, thank you from Florida Greg.

    • @foxfamilyheatingandaircond4696
      @foxfamilyheatingandaircond4696  2 ปีที่แล้ว

      Awesome! Thanks!

    • @truthmatters6719
      @truthmatters6719 ปีที่แล้ว

      ​@@foxfamilyheatingandaircond4696 great video sir! Just a quick question, if there's no liquid line service valve how do I measure superheat?

  • @bikerbobcat
    @bikerbobcat 10 หลายเดือนก่อน +10

    The way I was trained was to verify Airflow (filters, coils, fans, obstructions) then Electronics (motors, capacitors, controls) before ever putting gauges on. In 10yrs residential and light commercial I've found far more bad customers than bad TXVs. This is a great video, thank you.

    • @rickacton7540
      @rickacton7540 หลายเดือนก่อน +1

      whats a "bad customer"

  • @smacleod69
    @smacleod69 ปีที่แล้ว +13

    Actually with the 2007 regulations. Systems did not get more efficient with txv's. Its was because the suface area on the evap and condensor coils got bigger to absorb and reject more heat and humidity. Goodman proved this while staying with a piston metering device.

    • @marcost9461
      @marcost9461 29 วันที่ผ่านมา

      Yes 100

  • @marconantel7735
    @marconantel7735 2 ปีที่แล้ว +1

    I loled at the guy hammering the tire when you said tap on it with a tool

  • @InsideOfMyOwnMind
    @InsideOfMyOwnMind 2 ปีที่แล้ว +3

    I had a TXV diagnosed some years ago and they asked me for a glass of ice water. At the time I didn't know it was for the diag process but learned a minute later. He correctly called for the TXV. And yes, the system did perform somewhat better while the part was on order. Thing is, I kept the system operating right on the knee between function and failure by resting it periodically when it began to faulter so when he got here it was a no brainer compared to what it might have been. In other words, I did not let the compressor go thermal but the temps/pressures were still off so he could see in a snap what was up.
    Thanks for another nice tight discussion.

  • @michaelmaclachlan2152
    @michaelmaclachlan2152 2 ปีที่แล้ว +6

    Great explanation!
    As a first year tech, I can't tell you how helpful this is to grasp the concepts of refrigeration.
    The illustrations we're especially helpful.

    • @foxfamilyheatingandaircond4696
      @foxfamilyheatingandaircond4696  2 ปีที่แล้ว

      Perfect!

    • @LuisLujan-xc7bd
      @LuisLujan-xc7bd 10 หลายเดือนก่อน

      Could you please share the illustrations? I'm having a hard time opening the link. I'm guessing it's no longer good

  • @dnell6854
    @dnell6854 ปีที่แล้ว +2

    I like that temperature method,Thanks for sharing

  • @jmead6121
    @jmead6121 11 หลายเดือนก่อน

    Thanks great explanation of TXV operations ..30 yrs in & I take notes ..Tks again newbies will really Love the tutelage

    • @bikerbobcat
      @bikerbobcat 10 หลายเดือนก่อน

      Every day I learn something new.

  • @victorebolum1583
    @victorebolum1583 11 หลายเดือนก่อน

    All your videos are thoroughly presented. A real teaching moment. Thank you.

  • @MsFishingdog
    @MsFishingdog 9 หลายเดือนก่อน +1

    Great video

  • @watermanone7567
    @watermanone7567 2 ปีที่แล้ว +4

    Excellent video and explanation. Thanks

  • @marchomeautorepairs
    @marchomeautorepairs ปีที่แล้ว

    Keep up the good work

  • @scottgodwin3422
    @scottgodwin3422 ปีที่แล้ว +2

    Great info thanks

  • @dysfunctionalgamingveteran7753
    @dysfunctionalgamingveteran7753 2 ปีที่แล้ว +5

    I use the field piece smans. When talking to other techs about my pressures I always give them both pressures and temps

    • @InsideOfMyOwnMind
      @InsideOfMyOwnMind 2 ปีที่แล้ว +1

      That's great, and then if they ask you what refrigerant you're dealing with you just learned something about the tech you're talking to.😂🤣😋😎

  • @eulaliorodriguez5325
    @eulaliorodriguez5325 9 หลายเดือนก่อน

    Thank you for sharing this video.

  • @marybethshipley2969
    @marybethshipley2969 ปีที่แล้ว

    Thank you so much!

  • @hookedup9424
    @hookedup9424 2 ปีที่แล้ว

    Good video

  • @michaelcostello6991
    @michaelcostello6991 2 ปีที่แล้ว +1

    Thanks

  • @jascam1
    @jascam1 ปีที่แล้ว +1

    Excellent video, my installer wants to replace my TXV for the second time ( replaced with a piston while txv was ordered) on a 2 year newly installed SEER 16 Goodman Heat Pump. My temp is set on 77 degree but runs for 25 min on and 5 min off to do the job, this doesn't sound right. I need a good A/C tech in SW Florida.

    • @anthonybernier9952
      @anthonybernier9952 10 หลายเดือนก่อน

      Are you near Pensacola Florida?

  • @hectordaniel30
    @hectordaniel30 หลายเดือนก่อน

    My man

  • @cannadaincowboy
    @cannadaincowboy 2 ปีที่แล้ว +1

    With a heat exchange unit also can you cycle from heat to cool to see if the valve frees up? Would this damage anything doing this when the ambient temperature is in the high 90,'s to low 100..?

  • @zproxiimiity7733
    @zproxiimiity7733 8 หลายเดือนก่อน

    Great video. Where can I get the flow chart? The link is broken!

  • @user-vo9ho4vd9h
    @user-vo9ho4vd9h 11 หลายเดือนก่อน +1

    Does anyone know where to find this flow chart on the video? I click on the link but it is expired

  • @mackman77095
    @mackman77095 9 หลายเดือนก่อน

    what is the step where it is correct subcool but high superheat? I dont see it on a the chart.

  • @petesingh292
    @petesingh292 2 ปีที่แล้ว +1

    Great video Greg, but to get flow chart for txv?

  • @leomerino3906
    @leomerino3906 10 หลายเดือนก่อน

    Anywhere of getting that chart

  • @carltonthomas4819
    @carltonthomas4819 2 ปีที่แล้ว

    When looking for txv everyone says to look at evap core but on york they are in the heat pump. Should I use super heat or subcool? Thanks!

    • @robertcherry4971
      @robertcherry4971 2 ปีที่แล้ว +1

      There should be one TXV at the condenser and another TXV at the evaporator on a Heat pump.

  • @allanbrito13
    @allanbrito13 2 ปีที่แล้ว +4

    I had one intermittently making the compressor pull into a vacuum

  • @seek3n
    @seek3n 10 หลายเดือนก่อน

    Hello, why does every CARRIER i put in (litterally 10 outta 10). always have 18-20 superheat and low liquid line pressure. Even with 13 subcool. Each install i spend like 3 days checking back and stuff. And I follow manufacturer installation religiously.

    • @xincai951
      @xincai951 6 หลายเดือนก่อน +1

      Have you figured out why? Do you need to adjust the txv?

    • @seek3n
      @seek3n 6 หลายเดือนก่อน

      @xincai951 no. They dont come with adjustable txv. I have to over size the coil at least half ton or slow down the fan 😅

  • @zacharyreed45
    @zacharyreed45 2 ปีที่แล้ว +1

    oat, iat, sst, lst, sh, sc.
    TH-cam makes the jokes with that flow chart.
    Tesp & use the dumb chart in the manufacturer install manual to (don't worry the installers chucked it in the trash for you) guesstimate your airflow.

  • @ChrisHVACguy
    @ChrisHVACguy ปีที่แล้ว +1

    most of those checks should have been done before putting on the gauges, but very nice flow chart!

  • @urvesh0607
    @urvesh0607 ปีที่แล้ว

    From where we order TXV valve?

  • @saltrue1555
    @saltrue1555 9 หลายเดือนก่อน

    Very good information. Thank you

  • @scottgodwin3422
    @scottgodwin3422 ปีที่แล้ว

    Hreat

  • @robertpalmatier2699
    @robertpalmatier2699 3 หลายเดือนก่อน

    Txv

  • @robertpalmatier2699
    @robertpalmatier2699 4 หลายเดือนก่อน

    Must be the txv

  • @UtwoBed
    @UtwoBed 10 หลายเดือนก่อน

    The link to the flow chart is dead.☹

  • @mariod850
    @mariod850 2 ปีที่แล้ว

    Great video

  • @thomasdanieltucker9257
    @thomasdanieltucker9257 ปีที่แล้ว

    Good video