Troubleshooting with Superheat and Subcooling (Piston)

แชร์
ฝัง

ความคิดเห็น • 65

  • @deelo04
    @deelo04 2 ปีที่แล้ว

    Thanks keep teaching us who can’t afford school you are a blessing

  • @gilbertjaramillo8735
    @gilbertjaramillo8735 ปีที่แล้ว +1

    Loved your video. I learned a lot via your four trouble-shooting scenarios. Thanks so much and keep up the good work.

  • @111000100101001
    @111000100101001 2 ปีที่แล้ว

    Great work and illustrations in throughly explaining how super, sub and temps all go together to tell a clear story of the HVAC.

  • @sylnyiasmith6183
    @sylnyiasmith6183 6 ปีที่แล้ว +1

    Your videos are extremely informative. I would like you to PLEASE do a video on how to remove/change slanted coils. I have searched and searched, but cannot find any information on slanted coils. Again. thank you for all the knowledge you have shared with us new technicians.

  • @evergriven7402
    @evergriven7402 6 ปีที่แล้ว

    Thank you for the time and knowledge in these videos

  • @cruzrobledo6631
    @cruzrobledo6631 2 ปีที่แล้ว +1

    your videos are well explained Thank you for the great job you do at explaining everything Thanks!

  • @leftright2
    @leftright2 6 ปีที่แล้ว +1

    very well explained very much helpful for me understanding the effects of wet bulb on a piston unit and superheat and subcool really is very important as is TD I see

  • @nsboost
    @nsboost 6 ปีที่แล้ว +1

    Ok so I'm a plumber who is not that old and body already being best to hell. I'm making the move
    into HVAC/refrigeration and been reading a ton.
    This was one of the best videos yet... I can tell your a badass tech. Definitely slow it down a bit (like when your describing abstract situations from what we are currently looking at) so.I can follow a bit easier.
    some OJT with you would be invaluable

    • @godoftheox2513
      @godoftheox2513 5 ปีที่แล้ว

      I worked on semi conductor equiptment and transistuoning into HVAC as well, how is it going for you

  • @saltrue1555
    @saltrue1555 6 ปีที่แล้ว +3

    Thank you I've learned something tks

  • @frankroper3274
    @frankroper3274 2 ปีที่แล้ว

    I like the movie "Sling Blade"...keep it simple! You come on a unit with a frozen evaporator cut it off. Check the filter(s). Put it in the heat mode and defrost the evaporator. Then put your gauges on it and see if it is low freon. You checking all this sub cooling and super heat when you could go and check for a stopped up filter and defrost the coil and sign off on it!

  • @jeffreycampbell5730
    @jeffreycampbell5730 7 ปีที่แล้ว +2

    Highly informative!!!!

    • @EdgeTekHVAC
      @EdgeTekHVAC  7 ปีที่แล้ว

      Thanks for the feedback. Check out www.edgetekhvac.com for more great tips.

  • @elementalsk8ter92
    @elementalsk8ter92 6 ปีที่แล้ว

    where can i get the formed used

  • @user-bp8ef7ye3q
    @user-bp8ef7ye3q 23 วันที่ผ่านมา

    Thank you very much for the tutorial, please sir,is superheat and sub cooling also use in air conditioning system that makes use of automatic expansion valve like cars?

  • @mark.r8900
    @mark.r8900 4 ปีที่แล้ว

    hi, i was working on an r22 system with fixed orifice. subcooling was at 9f and my superheat was 2f. the suction temp. was about 30f. there was lots of nice cold air coming out from floor register. please help as i have no idea what the problem is. thank you for all your helpful videos.

  • @rodneyrash6820
    @rodneyrash6820 5 ปีที่แล้ว

    thank you that was very helpful

  • @bhampresson
    @bhampresson 5 ปีที่แล้ว

    Great job keep it up!

  • @zoidelux
    @zoidelux 5 ปีที่แล้ว +1

    Please make more of these!! Overcharged system?

  • @eddihellya951
    @eddihellya951 6 ปีที่แล้ว

    Love the chart would like to get one for my younger techs. Would stop callbacks and senior techs getting a little miffed

    • @EdgeTekHVAC
      @EdgeTekHVAC  6 ปีที่แล้ว

      Thanks, Keith. We'd be happy to send you a copy. Please email us at hvac.communications@nortek.com to request a copy of the charts.

  • @Capafool
    @Capafool ปีที่แล้ว

    Today I actually had the "undercharge" condition(SH 30deg over target, SC 5deg) but my head pressure is 390 which seems high. Piston metering. Airflow good, filters clean. Afraid to add more refrigerant since due to high pressure. Am I concerned for nothing and should just add refrigerant and only look at temperature targets regardless of pressure? You mention "don't care about pressures", so perhaps I'm just overly cautious.

  • @user-my7wf3cn9n
    @user-my7wf3cn9n 2 หลายเดือนก่อน

    hello dear, I have a question: if we increase the volume or the size of the condencer in this case, we will have more air cool inside the car ?

  • @umarkhan-ze8qf
    @umarkhan-ze8qf ปีที่แล้ว

    Full restriction in the system will cause a pump down?

  • @louemmertz3797
    @louemmertz3797 3 ปีที่แล้ว

    How about doing one with the wrong orfices,to big and to small on heat pumps

  • @hashimshams9633
    @hashimshams9633 3 ปีที่แล้ว

    Good Morning Sir, thank you for all the valued informations, me and my colleges would like to see and hear from you the Signs and scenarios to check the charge of an Air Conditioner Evaporator having a high return air temperature.

    • @EdgeTekHVAC
      @EdgeTekHVAC  3 ปีที่แล้ว

      High return temperature is essentially high load, this will cause high suction pressure and high superheat and possibly high head pressure. To accurately adjust the charge you will need to run the unit for a while and get the high load under control before making final adjustments to the charge.

  • @fixmytoyota6319
    @fixmytoyota6319 6 ปีที่แล้ว

    Can you check superheat pressure on the low side when the heat is on? It seems that the pressure needle flips 180? When i put the ac on to test like i normally would I read 25lbs its like 65 degrees outside. I normally test at 90 degrees and get 115lbs

    • @EdgeTekHVAC
      @EdgeTekHVAC  6 ปีที่แล้ว

      Hi Jim, our technical services team recommends testing an A/C when it is 75 degrees outside or above.

  • @fatehyalgobaily8279
    @fatehyalgobaily8279 6 ปีที่แล้ว

    Are there any deferment between calculation super heat & sub cool at( refrigerator and air condition ) units ?

    • @EdgeTekHVAC
      @EdgeTekHVAC  6 ปีที่แล้ว +1

      Hello! Sub Cooling and Superheat are calculated the same on any refrigeration system, although the required superheat and sub cooling may change.

  • @ronhanish
    @ronhanish 3 ปีที่แล้ว

    i got R 22 system ,,,,low pressure on suction side averages 35 psi with high superheat of 62, discharge is 177 psi average. sub cool yesterday was around 12. any suggestions? also evap freezing.

    • @EdgeTekHVAC
      @EdgeTekHVAC  3 ปีที่แล้ว

      Please contact Nortek's technical service team at 1-800-422-4328 or contractorservices@nortek.com

  • @mark.r8900
    @mark.r8900 5 ปีที่แล้ว

    hi , how do you find the INDOOR superheat if there's no shrader port at the evaporator outlet? thanks.

    • @EdgeTekHVAC
      @EdgeTekHVAC  5 ปีที่แล้ว

      Hi Mark,
      Typically superheat is measured at the service valves at the condensing unit.

  • @ejs023
    @ejs023 6 ปีที่แล้ว

    Great work!. Can I get a copy of that form from you for training. I recall I had one way back in the day.

    • @EdgeTekHVAC
      @EdgeTekHVAC  6 ปีที่แล้ว +1

      We'd be happy to send over the job sheets. Please email hvac.communications@nortek.com

  • @saltrue1555
    @saltrue1555 6 ปีที่แล้ว +2

    Hopefully you make more videos

    • @EdgeTekHVAC
      @EdgeTekHVAC  6 ปีที่แล้ว

      Thanks, Sal! We also have more videos on edgetekhvac.com

  • @kodykendall
    @kodykendall 3 ปีที่แล้ว

    Is there somewhere we can view/download the job document that you're using in the video?

    • @EdgeTekHVAC
      @EdgeTekHVAC  3 ปีที่แล้ว

      You can find the documents here: literature.nortekhvac.com/Unbranded/HVAC/SEARCH/0E43A926-5BF6-2AE6-1C15-733CDF8E2106

  • @EnjoyCalculus
    @EnjoyCalculus 2 ปีที่แล้ว

    How do I know what the operating pressures of a system should be?

    • @EdgeTekHVAC
      @EdgeTekHVAC  2 ปีที่แล้ว

      Please contact Nortek Technical Support for assistance 1-800-422-4328

  • @dasikalyan
    @dasikalyan 4 ปีที่แล้ว

    If you are here to learn about restriction with a piston you can jump to 7:40

  • @markmonaco8901
    @markmonaco8901 6 ปีที่แล้ว

    what would cause superheat to fluctuate up and down 8 my superheat would be at 14 and go down to 6 then go up to 20 but the pressure is high and low will stay the same?

    • @EdgeTekHVAC
      @EdgeTekHVAC  6 ปีที่แล้ว

      Hi Mark, Insufficient airflow or improper sensing bulb mounting causing TXV to hunt.

    • @markmonaco8901
      @markmonaco8901 6 ปีที่แล้ว

      Thank you

    • @Ephbaum
      @Ephbaum 6 ปีที่แล้ว +1

      Could be the bulb. Could also be non-condensables in the system. Meaning the system wasn't evacuated properly and you have something other than pure refrigerant in there.

  • @mpugliano
    @mpugliano 7 ปีที่แล้ว

    Is that sheet down loadable I'd love to play with it. Very nicely done.

    • @EdgeTekHVAC
      @EdgeTekHVAC  7 ปีที่แล้ว

      Hi Mark,
      I'd be happy to send you a copy. Please email hvac.communications@nortek.com

    • @ChandraMohan-sm6cp
      @ChandraMohan-sm6cp 5 ปีที่แล้ว

      @@EdgeTekHVAC hi sir, i still confusing in superheat and subcool... what is standart range for superheat and subcool? Even reciprocating compressor also same range as u calculating now? Our system dont have indoor blower... our system connected chill water tank..

  • @juliofelix2724
    @juliofelix2724 7 ปีที่แล้ว

    hi my a/c high side is low that is the piston or the coil

    • @EdgeTekHVAC
      @EdgeTekHVAC  7 ปีที่แล้ว

      If the high side is low and the suction is normal to high it
      could be an oversized piston or improperly installed piston more than likely
      not a coil issue.

    • @juliofelix2724
      @juliofelix2724 7 ปีที่แล้ว +1

      i need to replace the drier filter on the condenser

    • @juliofelix2724
      @juliofelix2724 7 ปีที่แล้ว

      thank you

  • @dongbao240
    @dongbao240 5 ปีที่แล้ว

    It is great if viewers can see whole drawing behind presenter. Most of time, the view of right end is blocked

  • @TheEauto
    @TheEauto 7 ปีที่แล้ว

    you talk about low air flow across indoor coil , low vapor line temp. , What about to much air flow across indoor coil , will you get high vapor line temp ?

    • @EdgeTekHVAC
      @EdgeTekHVAC  7 ปีที่แล้ว

      Hello - the answer is yes. The examples provided were just some examples.

  • @mbranbb
    @mbranbb 4 ปีที่แล้ว

    How do you know when your subcooling is too high or too low on a piston system? I guess what I’m asking is what is the ideal subcooling supposed to be on a piston system?

  • @joeschneider67
    @joeschneider67 2 ปีที่แล้ว

    That's why I NEVER use pistons. I always look for TXV

  • @jaykemm3472
    @jaykemm3472 ปีที่แล้ว

    I THOUGHT I TOLD YOU KIDS TO STAY IN THE CAR!!!