SOFT STOREY AND IT'S SOLUTION | EARTHQUAKE RESISTANT DESIGN | CIVIL ENGINEERING

แชร์
ฝัง
  • เผยแพร่เมื่อ 25 พ.ย. 2024

ความคิดเห็น • 24

  • @rekharokalla6606
    @rekharokalla6606 4 ปีที่แล้ว +3

    Very well explained on soft storey very useful information.

  • @binayaksamanta863
    @binayaksamanta863 ปีที่แล้ว

    Please upload more videos on this kind of topics. Thank you

  • @fahimahmedbhuiyan2252
    @fahimahmedbhuiyan2252 3 ปีที่แล้ว +2

    very informative and well explained! thank you very much

  • @bhagyakilli5556
    @bhagyakilli5556 4 ปีที่แล้ว +2

    Good concept and explanation😊

  • @indramlimbu6886
    @indramlimbu6886 2 ปีที่แล้ว +1

    Well explained 👏

  • @GVlogsNarlayt
    @GVlogsNarlayt 4 ปีที่แล้ว +1

    Good job

  • @hydrogenperoxide9995
    @hydrogenperoxide9995 3 ปีที่แล้ว +1

    Easy to understand!

  • @GVlogsNarlayt
    @GVlogsNarlayt 4 ปีที่แล้ว

    Very good editing and info

  • @ojasyadav9020
    @ojasyadav9020 4 ปีที่แล้ว

    Excellent

    • @acecivilengineer6863
      @acecivilengineer6863  4 ปีที่แล้ว

      For any topics in your interest, u may comment. Always there to help with the best of my knowledge 😊

  • @itssecret01
    @itssecret01 ปีที่แล้ว

    Thank you sir 😍, which software you are using to teach sir?

  • @pranithaadarshce_tutorial2423
    @pranithaadarshce_tutorial2423 4 ปีที่แล้ว

    Very professional video eswar...keep it up

  • @cosmitto2k194
    @cosmitto2k194 3 ปีที่แล้ว

    Shear wall idealisation.

  • @anastaha2438
    @anastaha2438 ปีที่แล้ว

    Thank you, I need to know, when i checked by etabs for soft story check, it showed me that percentage is ok ( i.e >70%) ,so no soft story is as what i can conclude. Does that mean that the situation is ok in earthquick ?as the checked floor is basement floor ( parking lot) and no walls or stiffness materials are used to cover the perimeter area of the parking floor

    • @acecivilengineer6863
      @acecivilengineer6863  ปีที่แล้ว

      Soft storey check is performed only to ensure that there is no drastic difference in stiffness between adjacent floor levels, which would lead to heavy concentrated forces at a particular diaphragm. Passing in a soft storey check doesn't mean that the situation is adequate for seismic loads completely.

  • @MUHAMMADIMRAN-lt4vf
    @MUHAMMADIMRAN-lt4vf 4 ปีที่แล้ว +1

    any difference between soft and weak story?

    • @acecivilengineer6863
      @acecivilengineer6863  4 ปีที่แล้ว +5

      Yes, there is a small difference. Soft storey is the one which the lateral stiffness is less than 70
      percent of that in the storey above or less than 80
      percent of the average lateral stiffness of the three
      storeys above.
      Weak storey is one in which the storey lateral strength is less
      than 80 percent of that in the storey above.

  • @cosmitto2k194
    @cosmitto2k194 3 ปีที่แล้ว

    Sir can u explain link beams

  • @poojahs9961
    @poojahs9961 3 ปีที่แล้ว +1

    Please explain IS:1893 code