Building & Installing 40' Steel Roof Trusses

แชร์
ฝัง
  • เผยแพร่เมื่อ 14 ต.ค. 2024
  • The entire roof build process for a 40' x 72' or 12.19m x21.9m structure.
    The steel trusses were constructed with 4" x 6" beam split long ways into two T sections and 1/8"x 1.5" angle iron webbing was used to increase the flange width.
    The Full span of the roof is 48' feet including overhangs.
    Purlins material used 2' x 4' x 1.6 mm rectangular tubing.
    The spacing between trusses is about 21' feet.
    X braces were made from 2 inch round tubing and 1/4" steel plate.
    Truss wall anchors were made with 3/8" steel plate.

ความคิดเห็น • 65

  • @neiljean-louis3372
    @neiljean-louis3372 11 หลายเดือนก่อน +1

    Sharp and clean job, I like the organization of the shop. The client must be happy and confident

  • @kedarnathmaharana7383
    @kedarnathmaharana7383 3 หลายเดือนก่อน +2

    Great video.Thanks

  • @wirngoericjaidzekaw.e.jeri9884
    @wirngoericjaidzekaw.e.jeri9884 2 ปีที่แล้ว +1

    Thii is just the kind of working hall I need with office

  • @BG-fm7zj
    @BG-fm7zj ปีที่แล้ว +4

    Fun to watch the fab/construction. I am an engineer and I am concerned that there is nothing keeping this structure from blowing over or falling over in wind/earthquakes. Would like to see substantial connections to the shipping containers or some diagonal wire bracing or interior walls to support the side walls. Best of luck! Looks great.

    • @CreativityUnleashed
      @CreativityUnleashed  ปีที่แล้ว +1

      I see what you mean but it has substantial columns.
      but also I didn't do that part. but I see what mean thanks.

    • @christopheralger1087
      @christopheralger1087 ปีที่แล้ว

      An engineer a expert at what ever you are doing

    • @arunarai5798
      @arunarai5798 ปีที่แล้ว

      U?

    • @exym969
      @exym969 ปีที่แล้ว +1

      I see your point. From what I see, the steel trusses will brace the two walls although don't know if this was considered during calculation of the frames. From a seismic POV there isn't that many mass to move around so I'm guessing wind will be a problem here in the future, there's a lack of horizontal bracing between trusses (although vertical ones do exist) on the roof plane. Ps: I'm a civil engineer.

    • @pashaigbal1657
      @pashaigbal1657 19 วันที่ผ่านมา

      ​@@CreativityUnleashed yoo bro may i get ur contact or ig i need ur help

  • @ruatarengsicolneyrengsi8924
    @ruatarengsicolneyrengsi8924 ปีที่แล้ว

    Very good work. Appreciate your explanation and demonstration. Wish you all the best in your next venture.

  • @nasqad3357
    @nasqad3357 ปีที่แล้ว +1

    Your awesome dude love the work my bro 😎

  • @somalia5019
    @somalia5019 ปีที่แล้ว +1

    New subscribed from Somalia

  • @Marcel1500
    @Marcel1500 ปีที่แล้ว +1

    Great job man!

  • @suriyadunya9994
    @suriyadunya9994 8 หลายเดือนก่อน

    Can you use these for residential homes? How do they compare to wood support construction

  • @bzmrgonz
    @bzmrgonz ปีที่แล้ว

    Do you have any videos on trusses for post frame and pole barns buddy? I like your style of presentation/explanation.

    • @CreativityUnleashed
      @CreativityUnleashed  ปีที่แล้ว +2

      thank you so much.
      and I do have some designs that could work well for them I recently finished a big project but haven't had time to finish the videos

    • @bzmrgonz
      @bzmrgonz ปีที่แล้ว

      @@CreativityUnleashed looking forward to it.

  • @atubeviewer4942
    @atubeviewer4942 9 หลายเดือนก่อน

    Are these done via an engineer specs or you just come up with the steel needed when doing one? Where is this located?

  • @Civilfromthebasics
    @Civilfromthebasics ปีที่แล้ว

    Great work. But I wanted to see how the trusses are connected to the wall.

    • @CreativityUnleashed
      @CreativityUnleashed  ปีที่แล้ว

      there is heavy play with bars welded to them embedded into the ring beams concrete.

  • @danielkarlsson397
    @danielkarlsson397 2 หลายเดือนก่อน

    Great video but i was thinking about welding penetration, Im not a professional but i weld alot and you do get enough penetration if you can burn through the material just adjust with power and speed right? no need to start/stop. Only time i do this technique is when the material is very thin and you have too much power

    • @CreativityUnleashed
      @CreativityUnleashed  2 หลายเดือนก่อน

      @@danielkarlsson397 you’re right you can have it set just right but when materials are painted or dirty and when you’re gap varies quite a bit, it can be challenging to have it set just right because just right is different for every joint when there’s a lot of variables and I would rather have to stop to let it cool for a second or two, then have to keep changing the machine all the time.
      If your material is very clean and your route opening is consistent. You can set it just right and not need to stop. And if done right that definitely makes for a better weld.

  • @abukarisualisusuhiyini7330
    @abukarisualisusuhiyini7330 ปีที่แล้ว +1

    How can one join the company if you are in Ghana

  • @melanastacio8816
    @melanastacio8816 10 หลายเดือนก่อน

    Good job bro..Where is this house built at? Concrete hollow blocks?

    • @CreativityUnleashed
      @CreativityUnleashed  10 หลายเดือนก่อน +1

      Yes concrete hollow blocks but it has a lot of columns with very heavy rebar it's a meeting building.

    • @melanastacio8816
      @melanastacio8816 10 หลายเดือนก่อน +1

      @@CreativityUnleashed Those column rebars in the cinder blocks, tied with one across every 3 layers are unbreakable bro. Where is this house built at in what weather condition?

  • @niponfabrication4339
    @niponfabrication4339 2 ปีที่แล้ว

    Sir Aap log toh lifts se utha rahe ho.... Humlog toh khud se uthaane parte hai.. Love from India🇮🇳

  • @commercialbroilerchicken3399
    @commercialbroilerchicken3399 2 ปีที่แล้ว

    Great video, keep the good work 👍

    • @CreativityUnleashed
      @CreativityUnleashed  2 ปีที่แล้ว

      thanks!!!

    • @keavalientino
      @keavalientino 2 ปีที่แล้ว

      @@CreativityUnleashed great job. can i email you about the roof im making?

  • @vi683a
    @vi683a 2 หลายเดือนก่อน

    Splitting those Ibeams for Ts... you didnt have severly bent Ts?

    • @CreativityUnleashed
      @CreativityUnleashed  2 หลายเดือนก่อน

      @@vi683a no they were quite straight with a few clams in a little, pushing even by hand they straightened right out

    • @vi683a
      @vi683a 2 หลายเดือนก่อน

      @@CreativityUnleashed I seen many of I beams cut and they just spring apart , violently sometimes.

  • @Shikharg57
    @Shikharg57 5 หลายเดือนก่อน

    Amazing how can I get in touch with you.?

  • @diellzavishi
    @diellzavishi ปีที่แล้ว

    what type of foundation have u used? also i am interested for what this building is going to be used

  • @wirngoericjaidzekaw.e.jeri9884
    @wirngoericjaidzekaw.e.jeri9884 2 ปีที่แล้ว +2

    You got a bucket of g clamps mann

  • @zani6607
    @zani6607 8 หลายเดือนก่อน +1

    Sorry Bro, your trus join is wrong. You need to change the inner trusses/frames direction up side down. Make the frame formed by triangle shapes. It is strongest form of steel construction.

  • @thomasschafer7268
    @thomasschafer7268 22 วันที่ผ่านมา

    😅😅😅cool .but as a carpenter master i must say you need only a nail gun. 75mm nails and boards 1"x5".

  • @engineer_yulan
    @engineer_yulan ปีที่แล้ว

    3:52 why didn't you use Bolt connection to connect bootom cord?

  • @MaciejKomorowski-o3b
    @MaciejKomorowski-o3b ปีที่แล้ว

    I think you might step your game up with gutter outlets

  • @statutesandordinances5155
    @statutesandordinances5155 ปีที่แล้ว

    Why are the roof trusses not supported on the columns?

    • @CreativityUnleashed
      @CreativityUnleashed  ปีที่แล้ว

      I believe there were some mistakes on the engineers drawings and where they ended up putting them but there's a strong rainforest header beam.

    • @Gary-pogi
      @Gary-pogi 10 หลายเดือนก่อน

      No need, you are free to put the main trusses where you like on the roof beam. Any load is carried by the beam to the columns.

  • @abdelaziz0365
    @abdelaziz0365 2 ปีที่แล้ว +1

    Love it

  • @legitte_7014
    @legitte_7014 ปีที่แล้ว

    How did u connect the steel truss to the loadbearing wall🙏

    • @CreativityUnleashed
      @CreativityUnleashed  ปีที่แล้ว

      They are welded to 3/8 plate that has been embedded or bolted especially to the wall

  • @appdevtyfy2643
    @appdevtyfy2643 ปีที่แล้ว

    what tube dimension can be used as a replace of half beam?

    • @CreativityUnleashed
      @CreativityUnleashed  ปีที่แล้ว +1

      There are a lot of variables to take into consideration so it would be difficult to say right off.

  • @juantejada6668
    @juantejada6668 ปีที่แล้ว

    Pretty soon (in 3 to 4 months) I'd need to do a roof like that one, in an "L" shape building (6 walls only) for an activity saloon for a church near Barahona (right before Duverge). Do you have a contact number? perhaps you could help me out with the roof.
    I'm a Dominican native Christian pastor in DR. Thanks.

  • @tigerlily2941
    @tigerlily2941 11 หลายเดือนก่อน +1

    What is with the calming music? It doesn't add up lol

  • @msrunuroy330
    @msrunuroy330 2 ปีที่แล้ว +1

    Good nice ok 👍

  • @tdmallet
    @tdmallet 2 ปีที่แล้ว

    What country is this happening in?

  • @nilomyki
    @nilomyki ปีที่แล้ว

    What was the location for this project?

    • @CreativityUnleashed
      @CreativityUnleashed  ปีที่แล้ว +1

      Santiago Dominican Republic

    • @nilomyki
      @nilomyki ปีที่แล้ว

      @@CreativityUnleashed Thanks for the reply.

  • @UzorAnyawu
    @UzorAnyawu 2 หลายเดือนก่อน

    Like is work

  • @ziauddin7948
    @ziauddin7948 5 หลายเดือนก่อน

    👍#🇵🇰

  • @jeffreyokai1674
    @jeffreyokai1674 2 ปีที่แล้ว +1

    Great Video. Thanks