R 22 GAS STANDING PRESSURE AND RUNNING PRESSURE ||AC GAS LEAKAGE TESTING |PANASONIC AC
ฝัง
- เผยแพร่เมื่อ 11 เม.ย. 2023
- R 22 GAS STANDING PRESSURE AND RUNNING PRESSURE ||AC GAS LEAKAGE TESTING |PANASONIC AC #mractech
Panasonic ac
ac wiring
ac wiring connection in hindi
AIR CONDITIONER WIRING
AC COMPRESSOR TRIPPING
AC GAS CHARGING
AC GAS LEAKAGE KAISE CHECK KARTE HAIN
AC REPAIRING IN HINDI CASSETTE AC LIGHT BLINK PROBLEM
SPLIT AC GAS CHARGING
AC GAS FILLING
R 22 GAS PRESSURE
AC GAS LEAKAGE TESTING WITH NITROGEN
AC REPAIRING
Informative knowledge 😮
Bahut bahut badhiya sar I love❤❤❤❤
Aapki gf hai ye 😂😂
Running Pressure 55 psig to 65 psig
rahana chahiye !
120-140 r32
Bahut badiya samjhaate ho aap me aapka chela ban jaaoo mujhe apna chela bana lo guru ji
Running pressure 65 to 70 hona chahiye.
Thoda overcharge ....
60 kaisa hai?
Thank you Bhai
welcome bro
Thanks bro❤
Nice❤
Zara 1/4 ka pipe sida modo bhai
Very nice sir ji ❤❤❤
Thanks
A666a ji aisa kuch naya laao .ye bahut purana hai
😊😊😊😊
Good information thanks 👍👍👍
Bhai R22 ka split ac hi per raining gas pressor 150 dekha raha hi our ampair 10 dekha raha hi kya foulty ho sakti hi 2 ton hi ac
Pumping problem hosakta
Nice
Good
Yes bos
Bhai ek achha
gauge metre or ek service Jet pump suggest karo bhai please
Value ka gague ideal ka pump best
r22 ka standing pressure 150 to 180 rehta hai
Very good 👍
Thank you! Cheers!
Sir Aap ka office kahan per hai
Aare tum to Hyderabadi ho bhai i know😊
Han bhai
Bai m apka fan hoon ekk baat btao please 1.5 ton mey dicharge. Presure krne ka koi jugad hai ja nhi
Bhai valve lagana padega jugad tuh kuch nahi
Sir mere pass lloyd ka ac hai 1.5 ton ka usmain 105 gas prasure hai sahi hai ya kam hai cooling child nahi hai kam chalu hai or agar kam he to solution kya
Konsi gas hai bhai
Good 😊
Thanks 😊
Good 👍
Thanks
Panasonic precise 65.70 psi Thika..
Hi bro im from hyderabad . Can you my ac's gas pressure is 30% down can you refill
Sorry bro
Yee 1/4 ke kya halat kri bichare ke 😂😂
Bro suggest me LG 1 ton lu ya fir Panasonic 1 ton ? (Inverter AC)
LG lelo
Sir Inverter ac hai Baar baar Trip ho raha hai .... aur Dry mode par 2 3 Ghante chalke Off ho jata hai .... Normal mode par to chalta hi nahi
Bhai outdoor pcb me kuch problem hosakti hai yahi kisi sensor ka hosakta aap kisi technicians se repair karwaiye Jo bhi problem hoga solve hoga
@@MrAcTech. Koi Bol Raha Hai Outdor Location change kijiye koi Bol Raha hai Sensor Change kijiye ..... Sir PCB Me Folt hota to Dry mode Ecco mode me Bhi nahi chalta na
Bhai Cool mode per Ac nahi Kam kar raha matlab pcb se signal nahi jaraha ac ka outdoor on karne k liye
Hosakta Jo cool mode ka function hai usme problem aagayi ho
Yah sensor sahi se temprature read nahi kar rahe
Agar koi error code aaya toh uske hisab se kam karsakte
Werna toh inverter AC me sub kuch check karna padega step by step
@@MrAcTech. 8 10 Baar Trip Ho kar Phir E8 F5 Error aata hai Sir .... aaj Puri raat Dry Mode par chala ac
Agar Sensor ka Folt hoto to sir Dry mode aur Ecco mode par Bhi nahi chalna chahiye na ???
To jese hum gas 150 rakhwate he 1.5 ton inverter ac me, to gas Ac running pe 150 kerwai jai yan off me?
Bhai inverter AC off me 150 nahi rahta 250 rahta
In summer standing pressure more than 180.
Bhai charging Line Air Force ke hai?
shad
Vo running ma barabar hojata bhi
bhai 50 nai aara
30 aara aur DISCHARGE pipe per ice bhi aara
Ye mere sat v hua hai 😁😂 bohot bar
Manifold guage use kiya karo
Kiu Bhai koi faida hai kia khaas
Sir kon gas ar kato back paser aktu likha daben
Replay
Bhai ye pressure gauge kaha se kharida mujhe bhi lena hai
rani gunj
Sir same problme hui thi mere sath
Standing 150 psi tha
Aor tunning 15 psi ara tha
Aor discharg pap pe burf bhi ara tha
To has hi kam thi na ??
haan bhai
Standing pressure kavi kavi thik bata raha lekin running pressure sahi nahi hai to.....kyu standing pressure sahi batata hai
kiu ki liquid gas LEAKAGE kar jata hai
vapor rahjata hai
Bhai ka jawab bilkul perfect rehta
Avon quality ke. Technician hai bhai
Salam h bhau aapko
New panasonic inverter ac gais v theek h coling nhi ho rahi kiya poroblam hoga
outdoor run kar raha
Yes chal rha h
@@Reyaz163 tab toh gas ka hi problem hogaa
Apko kaise maloom gas thik hai ??
Bhai new AC lena he, to panasonic lu ya Samsung ya daikin
For long life and good service in lucknow
Daikin
Mai lucknow me hee huu aur daikin hee prefer krta huu sab ke liye best hai bhai
hitachi best on krte he chill kr dega
Dost mera split ac ka remote goom Gaya aur muje ac chaloo karna hai to kasai kare
Manual button rahega 90%
Yah phir mi mobile
Yah universal remote
Bar bar battery. Nikalne se bar bar universal code ke chakkar me customer k yha jana padta
Pcb khol ke match kra ke le aate ham log wo behtar rehta
Sir mujhe bhi kam sikhana hai aap sirf
Nahi bhai kam nai hai apne pass
@@MrAcTech. bdhya khel gye Bhai jawab dekar
Kaam nhi h apan paas 😂😂😂
Bro metre konsa hai premium lag raha hai please iska link dalo
Value ka hai
@@MrAcTech. price
@@xnovaarss6172 1500
@@MrAcTech. shukriya
R22 ka standing pressure 150-160 psig hota hai
Suction pipe e ice AA rha h to kya problem h a.c me
Indoor fan slow
Suction pe ice technician jo rehta wo use pta rehta waese bahut se fault rehte
Bhai gauge mast hai😇 online mil jayega kya
value ka hai bhai dekho
@@MrAcTech. 1400 somthing hai apne kitne ka purchase kiya
@@RaviKumar-qe9ww same
Value ka aur RothenBerger ka guage aur tools quality bdhya hone se mahnga hee rehta
Lekin kam paise me mera Baba ka hai guage aur bahut saal se use kr rha huu behtar hai
It's leakage i think .. 25 psi
Sir Mera ac ka outdoor ka coil aluminum tha Maine copper ka replace karaya after 2 Yeats coz leak hona chalu ho gayi thi... to isse ac ki cooling mein bhi affect aayega?
Nahi cooling same rahegi
@@MrAcTech. Sir cooling Kam Kar diya hai ac ne
Old city ma kaha bhai.or ap ka name Kay ha 😊
Mera name ghouse hai bhai
Mere Sath Huwa h Bhhoot bar sir😢
R32 natural gas h na bro ya fir r22😂😂
Dono bhi natural nahi hai
R32 running pressure kitna hai ?? 1.5 ton ac
Standing pressure par kyu biswas na kre
abhi aapne nahi dekha ??
standing me pressure barabar hai
magar on hone per kam hogaya
Bhai ager ges name na likha ho to kese confirm karte hai ki ges r32 dalegi ya r 22
Machine ki age yah phir compressor per
Sar.Aap.kaha.se.ho
Hyderabad
Hona kitna chahiye . Mera 135 a raha hai running mai. Ac khas thanda bhi nahi kar raha hai
Compressor nahi chal Raha hoga aapka
Ac kitne prkar ka hota hai
standing preshar se kabhi ges cheek karte hi nhi aur pta nhi nhi lagega ges ketna hai 22 ges me 150 se le le 190 tak bhi jata hai wo mosam pe dipent karta hai abhi ek best tarika aya hai gej laga ke cheek karne ki zarurat hi nhi padegi M.P.R metar se hi ges cheek kar skte hai
Package unit me fan mode hota hai?
ha hota haina bhai
Es me problem Kiya hai Jo ESA hua
ac reinstallation kare gas kam hai
@@MrAcTech. Nahi gar R32ya R 410 Hoti to
@@moaneesh8082 toh kia bhai
aap bolna kia chahre saaf bolo bhai
samjh nai aaya
@@MrAcTech. Bhai reinstallation koi salution Nahi hai
Bhai tum Hyderabad ka dikra
How bhai
@@MrAcTech. hyd ma kaha rahte aap
@@Hyderabadpets110 old city side
Kya baat bol re baba
Mout dikh rhe bhai 😂😂 waha aane ko dil bol rhaa 😅
Bhai mera ek compressor hai vo humming ki avaj kar rha hai lekin start nhi ho rha ha
चेंज कर दो
bada capacitor se starting do
yah phir uske base per hathodi se halka hath maro
phir on kar k dekho
Outdoor me nhi laga hai compressor to uthaa kr niche fek do. Yaa fir bhia 1.5 ton ka h to 80-100 ka starting do start hona rhega to ho jyega agar start ho gya tk bhai PTCR laga dena machine me bina startting capacitor ke ac chalega with ptcr or running ok👌👌👌
Bhai agar कंपाउंड गेज se gais chek krna hai to uska handil khula रहेगा ki bnd rahega..... Plz riply
Bhaai poora hi Roman English me likhdete aap padhne nai aaraha hindi nai aata
Manifold gauge k price kitna hai
4k hai bhai 4 lines
Bro Panasonic AC me E1 error h to kya problem hai please help me
indoor fan motor or sensor
All ac error code load kr lo foran pta chal jata bhai
Aur kabhi kabhi aisa bhi hota koi wire cut rha tab bhi error kuch btata aur fault dusra hota
Aap smjh gye honge ok
Condenser me minar leak hoga toh ise hota 👍
To cooling q nahi hota he pressure 150 ho to.
Kiu k voh Khali vapour hai
Bhai R22 me
standing 150psi hai or
runing me 40psi hai
amp 10 le raha hi jo ki name plate Diya Hai
2 ton ka ac hai
Discharge line per ice a rahi hai
Kya problem ho sakti hai🙏
Gas leaked hai bhai
Sir... Please Answer I Reset you...R134a Gas Pressure running (Section and Discharge)With Standing pressure with can Please Answer
Bhai 134 per kaam nahi kia mai
is ka running pressure kitna hota hy r 22 ka
65
Sir sun light mein compressor or fan on ho jatta hai lekin night time nhi on hota kya problem hogi
Continue chalne ki wajah se over heating ho sakta
Sir ye gaeg metter fridge meai ues ker sakte hai
Haan bhai
Bhai iski indoor me leakage hai jao check krlo indoor me leakage
Thik bhai
Gas kahan gai leak check karo gyan na pelo
Ac Installation kare baba
Aap hee leak sahee kr do
Jo krta h kaam wo behtar janta hai technician
Mr ac tech bdhya information dete hai jo new technician h unko help milti
Haier ka AC liya hai...Low cooling aur indoor water leakage ka problem face kar raha hu... Installation ke time muje itna technical knowledge nahi tha lekin installation time par E7 error show kiya tha aur installation ke time AC vaccumm bhi nahi kia tha....Koi solution batao. New complaint raise karoonga toh kon kon se test karaun service centre valo se..Muje low gas/ gas leakage ka problem lag raha hai
Hosakta gas leakage problem ho
Warrenty me aajaiga shayd service centre me complaint kijiye hojaiga kam
बरफ आ जाता हे भाई गैस कम होने पर
Hi dear. Apse contact kaise krskte
hello
mr ac TECH yt
insta pe msg karo
@@MrAcTech.ok
R 32 back pressure Kya hota hai
Suction??
Discharge??
Yah standing konsa
Suction aur discharge dono ka
Humne Do Ac utare theey aur Dobare fit karye hai tu utarke dusre room ma sir ja 60 gas batai bande ne tu 150 gas ki ja batao ke gas kam ho jatai hai dosri room ma change krke ac lagne se bhai batao gas dalwai padti hai
Aisa toh nahi hota agar running hai toh running rahta yah kuch Valve me leak hoga
Charging line kaun si company ka kya naam hai
Value
Aisa kis wajah se hota hai ki standing sahi dikha rha aur running kam hota hai
Gas leak problem
गैस प्रेसर स्टैंडिंग को ही परफेक्ट प्रेशर कहेंगे।
भाई तुम ये गलत सीखा रहे।
रंनिंग में अगर कैप्लरी पार्शल चोक रही तो भी प्रेशर कम बताएगा। अगर और ज्यादा गैस डालेंगे तो कुछ भी हादसा हो सकता।
जिसने भी इस मशीन को लगाया होगा उसने लगाते समय ठीक से वैक्यूम नही किया होगा तभी ये प्रॉब्लम आ रही।
Mere bhai agar ac me gas leak problem ho
Aur gas leak indoor cooling coil me yah caplery me ho toh liquid gas aam taur pe leakage karjata hai
Aur sirf vapour gas rahjata hai
Tab agar ap gas check karo toh gas pressure barabar batayega
Jaise hi ac ko on karoge toh running me pressure kam hojayega
Agar kabhi mouqa mila toh usme check karo
Discharge line nahi liquid line hai woh
Good