How to install Conventional Manual Call Point

แชร์
ฝัง
  • เผยแพร่เมื่อ 11 พ.ค. 2021
  • this video shows how to wire a Conventional Manual Call Point to the conventional fire alarm system panel.(AW-CMC2166-6)
    More details:
    asenware.com/products/detail-...
    Conventional manual call point is designed to be use with an intelligent two-wire control system. If it is pressed after a fire is manually confirmed, an alarm signal may be sent to a fire
    alarm control system which will, after receiving the alarm signal, display the equipment status of the manual fire call points.
    Welcome to inquiry us
    Email: info@asenware.com
    Tel: 0086 13922805301
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 17

  • @twahashearer8302
    @twahashearer8302 3 ปีที่แล้ว +1

    This is a good demonstration, please provide more video clips for installation of this product

    • @ASENWARE
      @ASENWARE  3 ปีที่แล้ว +1

      thank you for your support,will do more for technical support also

  • @alexandermokele7076
    @alexandermokele7076 2 ปีที่แล้ว

    Nice one

    • @ASENWARE
      @ASENWARE  2 ปีที่แล้ว

      Thank you for your support

  • @ronelomingoy8320
    @ronelomingoy8320 3 ปีที่แล้ว +1

    Thank's. More demo videos pls.. dip switch setting how it works? Thanks.

    • @ASENWARE
      @ASENWARE  3 ปีที่แล้ว

      thank you for your support,if your manual call point it's the last one device in the zone ,you could check our video from 4:34 to 5:20 to learn how to set the dip switch,or You can contact us through sales03@asenware.com

  • @nonamefornow1465
    @nonamefornow1465 3 ปีที่แล้ว

    Helpful. Good job

    • @ASENWARE
      @ASENWARE  3 ปีที่แล้ว

      Thanks for your support

  • @francispascua9861
    @francispascua9861 2 ปีที่แล้ว

    What best remedy if the IC in facp is broken, can I replace the IC OR I will get another new fire alarm control panel?

    • @ASENWARE
      @ASENWARE  2 ปีที่แล้ว

      Can you share with me the model number of the panel ? Kindly share with us the product picture or video to info@asenware.com ,we have professional engineer can give you solution.

  • @princessroseeugenio5679
    @princessroseeugenio5679 ปีที่แล้ว

    If the mcp is the beginning ..we don't need to remove the jumper in eol??

    • @ASENWARE
      @ASENWARE  ปีที่แล้ว

      Thank you for your support,If you have any technical problems, please feel free to contact us, E-mail: info@asenware.com Whatsapp/Wechat/Skype: 8613922805301. web:asenwarefire.com

  • @khaledawadh-vj3xn
    @khaledawadh-vj3xn หลายเดือนก่อน

    What will happen if we share the 6 and 2 terminals in every smoke detectors?

    • @ASENWARE
      @ASENWARE  หลายเดือนก่อน

      Hi dear, kindly see this wiring method for AW-CSD381-Conventional Smoke Detector:
      Wire connection point:
      No.2: IN + ( zone input + )
      No.6: Remote indicator(+) / Next detector IN (+)
      No.5: IN - ( zone input - )
      No.3: Remote indicator(-).

    • @ASENWARE
      @ASENWARE  หลายเดือนก่อน

      Welcome to contact us for more information:
      asenwarefire.com
      Email: info@asenware.com
      Whatsapp, Wechat, Tel: 0086 13922805301

  • @kevin00861
    @kevin00861 6 หลายเดือนก่อน

    How long can we extend the signal wire ?

    • @ASENWARE
      @ASENWARE  6 หลายเดือนก่อน

      Thank you for your watching and if you have any questions please send an Email to info@asenware.com. Our technical team will serve you.