Installing A Gas Fireplace

แชร์
ฝัง
  • เผยแพร่เมื่อ 24 ส.ค. 2024
  • Maplemtnfireplace.com | 801-489-5052
    We installed this builder grade gas fireplace into an unfinished basement. If you are beginning a home renovation the Napoleon GX36 Gas Fireplace is a great addition to your home. It is one of our best sellers and is reliable, efficient, and easy to install on your own if you are a DIY-er.
    ____________________________________________________________________
    We carry a variety of lines of Free Standing Wood Burning Stoves, stove inserts, gas free standing stoves and inserts, wood burning fireplaces, gas fireplaces, gas inserts, outdoor fireplaces, fire pits, Pizza Ovens, Barbecues, Hearth Pads, Stone, and accessories.

ความคิดเห็น • 91

  • @MarciaCristina-vk3qr
    @MarciaCristina-vk3qr ปีที่แล้ว +2

    i think the best produce in the price range. Very slick and stylish! Very easy to install ....got so many compliments

  • @adaptedbythedans
    @adaptedbythedans 7 หลายเดือนก่อน +2

    This is why I do my own work.

  • @DC-do8vd
    @DC-do8vd ปีที่แล้ว +3

    FYI, the installation manual states to discard the piece of insulation when switching from rear to top venting.

    • @sirnickschmidt
      @sirnickschmidt 5 หลายเดือนก่อน +1

      I was about to comment the exact same thing

  • @kelbyarimanaaliaga7297
    @kelbyarimanaaliaga7297 7 หลายเดือนก่อน +1

    Thank you for sharing! You guys make it look easy

  • @emilmaier2953
    @emilmaier2953 ปีที่แล้ว

    Good heater really like it it came in with a little dent on the top but I ain't no worry about it it won't too bad

  • @barrytarakoff3204
    @barrytarakoff3204 4 ปีที่แล้ว +4

    I just bought one of these and will be installing next week. This video is very well done and will be a great help for this project.

  • @chriscameron8115
    @chriscameron8115 3 ปีที่แล้ว +2

    Rookies, you connect gas and electrical before vent and final set to test fire, you can not pass c.s.s.t. thru the fireplace body. It must be sleved or you must use a termination fitting

  • @image662
    @image662 4 ปีที่แล้ว +10

    This video needs more views!

  • @farzadhamraz903
    @farzadhamraz903 2 ปีที่แล้ว +1

    Thanks for informative video. Keep doing the good job guys. All the best

  • @worldwidesports4k
    @worldwidesports4k 9 หลายเดือนก่อน

    you guys did a great job

  • @sbartelt1
    @sbartelt1 3 ปีที่แล้ว +1

    Thanks for the video. Going to be putting one in soon and this is a good start for us.

  • @stevehenderson9074
    @stevehenderson9074 ปีที่แล้ว

    Great video. Thanks for sharing.

    • @RitzyTrailerII
      @RitzyTrailerII 7 หลายเดือนก่อน

      It'd be even BETTER if they bothered to answer some of the people's questions.

  • @aliveandwell2078
    @aliveandwell2078 7 หลายเดือนก่อน

    Great job on the video!!!!

  • @ManCaveMechanic
    @ManCaveMechanic 4 ปีที่แล้ว +2

    Nice job on the video. Right to the point. I am surprised that you don't have more views. This was the best video I found in regards to setup. Thank you

    • @ManCaveMechanic
      @ManCaveMechanic 4 ปีที่แล้ว +1

      1 question though at 1:32 in your video you say to reinstall the insulation on the back. The installation manual says (pg24) to discard that insulation. Please advise

    • @maplemountainfireplaces5648
      @maplemountainfireplaces5648  4 ปีที่แล้ว

      Thank you! We're glad we could help.

    • @maplemountainfireplaces5648
      @maplemountainfireplaces5648  4 ปีที่แล้ว

      @@ManCaveMechanic We definitely would advise you to follow your manual. Thank you for pointing that out for us.

    • @mkaratas83
      @mkaratas83 4 ปีที่แล้ว

      @@ManCaveMechanic Good point! You have to discard it! It's fire hazard. It'll soot, too.

  • @gigicordoves700
    @gigicordoves700 หลายเดือนก่อน

    Hi great video. I'm installing mine and I need to level it and bring it slightly forward, it's leaning back a little about 1.5 inches. Is it safe to use wood wedges/shims or to bring it forward.

  • @dwindi0406
    @dwindi0406 ปีที่แล้ว

    Nice video. Thank you

  • @adventuresinblack
    @adventuresinblack 8 หลายเดือนก่อน +2

    How tf do you remove one of these dumb things?? I can’t get the rear vent pipe off and can’t fit it out my door to trash it.

  • @honoluluharry7664
    @honoluluharry7664 3 ปีที่แล้ว

    Great breakdown...awesome job guys..!!!

  • @walterteague4814
    @walterteague4814 3 หลายเดือนก่อน

    In a lawsuit right now. This fireplace was installed. Shortly thereafter, the condo almost burned to the ground. 1/2 million in damages.

  • @voiceabove
    @voiceabove 3 ปีที่แล้ว

    Wow, so much effort. I'll just go chop firewood thanks....

    • @kinglyarab
      @kinglyarab 3 ปีที่แล้ว +3

      Nice logic buddy. its too much effort to install a gas fireplace which you wont have to do anything else again after its installed, but you’ll keep chopping firewood for the rest of your life, this is some next level genius at work

  • @opalparikh6483
    @opalparikh6483 2 ปีที่แล้ว

    Thanks a lot, guys, great video

  • @krishmaina
    @krishmaina 3 ปีที่แล้ว +2

    I have similar fireplace.i notice cildvair draft coming from it.builder says it's common in direct vent.is it so? I notice a hole left unclosed on the bottom and also the gas line hole is not properly sealed. What can I use to seal around the pipe.

  • @ErnestoMunoz2075
    @ErnestoMunoz2075 5 หลายเดือนก่อน

    How far needs to be from the back wall ??? 🤔🤔🤔

  • @PeterSchneemann
    @PeterSchneemann 3 ปีที่แล้ว +1

    IMPORTANT QUESTION: I have a new finished home without a fireplace. obviously the fireplace company I will call will have to destroy part of the wall to make holes. Will I need to wall other construction workers to fix the wall after that? Or does the fireplace company take care of all the damage needed to install the fireplace? And one final question: can a gas fireplace be installed at any exterior wall, or are there any conditions?

  • @RonVF
    @RonVF 10 หลายเดือนก่อน

    Great video,wish I saw this a month ago. I have been looking for a way to add 5’ of additional flex tube to my current piece of 8’. Do you guys sell 4.5/7.5 z-flex?

  • @MuhammadAli-gw7ub
    @MuhammadAli-gw7ub 4 ปีที่แล้ว

    Well done

  • @weekendwarrior3420
    @weekendwarrior3420 ปีที่แล้ว +1

    ... and that is how you get water inside your wall.

  • @ValveInteractive
    @ValveInteractive 2 ปีที่แล้ว +2

    Don't you have to have non combustible material on the wall between fireplace and wall insulation???

    • @jamesalexander5408
      @jamesalexander5408 ปีที่แล้ว +1

      I have the same question
      My fire place has a constant draft
      It is pretty noticeable

  • @LL-em3od
    @LL-em3od 2 ปีที่แล้ว

    Maybe you might be able to help me. Just have a gas fireplace installed vent pipe is condensating dripping water what’s causing it? Spray formed home tight.

  • @scubatom8232
    @scubatom8232 2 ปีที่แล้ว

    I installed my Nopolion ex42. Nothing happens when I hit the switch. The control module will not beep when I push program.

  • @tarzanjammyy
    @tarzanjammyy 2 ปีที่แล้ว +1

    What is the main reason for draft from the bottom of these direct vent gas fireplaces? I have a heat and GLO and cold air draft is coming from bottom.

    • @jamesalexander5408
      @jamesalexander5408 ปีที่แล้ว

      Same issue with me
      It seems like there is a constant draft

  • @johnjuha
    @johnjuha 3 ปีที่แล้ว

    How come you do not have any fireproofing around the wood? I heard you have to have 4 inches of clearance around insert. Fireproofing is costing me hundreds of dollars around an existing old wood burning fireplace.

  • @conniejohnson6910
    @conniejohnson6910 4 ปีที่แล้ว +1

    Your video was very informative. I bought a ventless gas heater, and I was wondering do you have to put cement board around the fireplace or just drywall... I'm not tiling around the fireplace.

    • @maplemountainfireplaces5648
      @maplemountainfireplaces5648  4 ปีที่แล้ว +2

      Thank you Connie. It's going to depend on the specific clearances of your fireplace but most likely you will need to do cement board.

  • @jmore4506
    @jmore4506 3 ปีที่แล้ว

    Good job, just cash the check!

  • @coltk2621
    @coltk2621 3 ปีที่แล้ว +1

    Good video! Self drilling screws made me laugh though lol. Self tap screw! I’m sure you knew that and just had a brain fart lol.

  • @zachenos544
    @zachenos544 4 ปีที่แล้ว +3

    Many thanks! I'm building my enclosure for a GS36 now and was doing some due diligence and found this video - to see you installing the same exact model is amazing. I'll be rear venting through an exterior wall with vinyl - any thoughts on the best vinyl shield? Everything keeps pointing towards a DuraVent Product - thoughts? Also - I had black pipe installed and run directly to the center rear of my bay, now that I see the gas inlet is on the side I guess I just run flex around to the inlet and allow for a deeper enclosure, part of me wonders if the heat generated in the enclosure is a consideration vs. the durability of the flex line?

  • @melvic4
    @melvic4 3 ปีที่แล้ว

    Can this be done after the house is handed over to us once it's finished by builder? They will rough in the gas line and the PowerPoint. Can I purchase the fireplace after handover and install it or is this going to be impossible? Please advise as they won't let us do anything if we're not doing it through them... Truth is if we were to do it through them, it would be too expensive 😏
    Thanks

  • @MrBbbbbbbbbbbrandon
    @MrBbbbbbbbbbbrandon 3 ปีที่แล้ว

    Dose black iron not rust and flake???

  • @dvana0206
    @dvana0206 3 ปีที่แล้ว +1

    We are in the process of having a contractor install a similar Gas Fireplace. I am wondering why the Cool Surface System (CSS) is not being addressed in any of these FP install videos I am searching for. Isn't CSS critical to the install of Gas Fireplaces?

  • @sha2828
    @sha2828 3 ปีที่แล้ว

    I have a two-sided-view Napoleon zero clearance fireplace box installed on cement floor. It has flex pipe and I want to lift it a couple of inches and allow for flooring so the bottom access grill can still be opened. Does a full sheet of OSB or plywood need to be slid underneath or could 2 “ bricks only be placed flush under the perimeter of the box? Would anything go wrong with the flex pipe if this is carefully done?

  • @alfredorivera22
    @alfredorivera22 2 ปีที่แล้ว

    Great video!
    May I ask What’s your framing dimensions?

  • @scottking3349
    @scottking3349 3 ปีที่แล้ว

    Can I vent the fireplace up through the roof of a house? I'm wanting to put a fireplace on an interior wall of a rambler style house with a vaulted ceiling.

    • @stickjr.3715
      @stickjr.3715 3 ปีที่แล้ว

      Yes! But there is codes that need to be met

  • @joescroggins7384
    @joescroggins7384 4 ปีที่แล้ว

    I have a gas fire place in 6 month old house. Everytime it rains it is humid we are getting horrible musty smell. What can I do?

    • @maplemountainfireplaces5648
      @maplemountainfireplaces5648  4 ปีที่แล้ว

      I would have someone come out and take a look at it. It's possible you could have some build-up somewhere but we would have to come out and troubleshoot to know what is going on.

  • @willmurrell9462
    @willmurrell9462 4 ปีที่แล้ว

    Thank you for the follow-up on the stones. Any thoughts on the switch.

    • @maplemountainfireplaces5648
      @maplemountainfireplaces5648  4 ปีที่แล้ว

      You bet! That actually goes for both the stones and the switch. As long as the new switch is recommended by the manufacturer you shouldn't have an issue trading them out.

  • @darm0030
    @darm0030 ปีที่แล้ว

    How do you insulate around it?

  • @juliamihajlovich
    @juliamihajlovich 3 ปีที่แล้ว +2

    This guy’s voice sounds like John C. Reilly

  • @allenletizia321
    @allenletizia321 3 ปีที่แล้ว

    1 that I looking at has 2 vent pipes . Feeding air coming down and vent out. Going up the stack . You know what name of flex hose? Are they s/s ?

    • @danlira929
      @danlira929 3 ปีที่แล้ว

      Those in the video are aluminum hoses, they seem to be 4" and maybe 6", but there are rigid ducts that are galvanized steel. They are not stainless steel.

    • @onekidthere
      @onekidthere ปีที่แล้ว +2

      B36 uses a 4"/7" pipe. Larger fireplaces by Napoleon will use a 5"/8". Interior pipe is the hot exhaust, exterior is the intake. Napoleon makes those kits for their fireplaces. There are lots of online dealers that sell them. Currently run around $350 or so for a basic kit with 5' of pipe and an exterior exhaust.

  • @penguincat33
    @penguincat33 3 ปีที่แล้ว

    Please respond 🤞: my direct vent fireplace has such a huge pilot light, that makes such a loud noise, but when I turn it down to a quiet volume using the red handle, as soon as I turn the fireplace on, the pilot light dies.... Any ideas?

    • @tonymarony1
      @tonymarony1 3 ปีที่แล้ว

      Hire a licensed gas fireplace installer/technician

  • @willmurrell9462
    @willmurrell9462 4 ปีที่แล้ว

    I have a similar fireplace but to be more specific it is 36 x 36 by FMI gas vent. Can I remove the logs and place colorful stones in its place for a more modern look. Also I have a wall plate switch connected, can I just disconnect it from the old switch to replace the switch with a new one.

    • @maplemountainfireplaces5648
      @maplemountainfireplaces5648  4 ปีที่แล้ว +2

      Hi Will,
      Great question. All units have been tested in order to be EPA certified, and not all gas fireplaces are created equal. We would recommend either going through your manual or calling the manufacturer/dealer to see what options they have for you. A lot of dealers will have ceramic rock kits for a more modern look, but a lot of rocks hold air and will pop once they are heated up which can be unsafe in an air tight gas fireplace.

  • @rhard007
    @rhard007 3 ปีที่แล้ว

    Question: Do these fireplaces heat up space or are they just for decoration?

    • @dinojay8410
      @dinojay8410 9 หลายเดือนก่อน

      They provide heat ... this particular model is 26,000 BTU with Natural Gas

  • @matthewlewis9967
    @matthewlewis9967 3 ปีที่แล้ว

    Do you think I could place it on top of a wood floor?

    • @dinojay8410
      @dinojay8410 9 หลายเดือนก่อน

      Check your local building codes.

  • @deniscastaneda397
    @deniscastaneda397 3 ปีที่แล้ว +1

    How about the fire retardant that is installed inside and around the framing?

    • @dinojay8410
      @dinojay8410 9 หลายเดือนก่อน

      Depends on your jurisdiction and applicable codes ... the manuals come with specifications for clearance between the firebox and the surrounding frame/mantel, etc.
      For our application we're using CGC Cement Board ½" thickness with steel framing studs. Insulation is a "rock wool" for 16" OC with Steel studs (2 × 4).

  • @kylehicks3794
    @kylehicks3794 3 ปีที่แล้ว

    Did you install the Napoleon tag on the glass or the screen barrier?

  • @philprowse8434
    @philprowse8434 4 ปีที่แล้ว

    I have a question I hope you, or someone on here might know the answer to. When they installed our fireplace, it was put between two windows. Problem is, it isn’t placed equally between the windows. There’s about 1” or less on one side and about 4” to the other and everything on the mantle is built centered and evenly spaced. Is there anything that would prevent me from rebuilding the mantle and moving the fireplace where it’s even between the windows for any reason? Thanks!

    • @maplemountainfireplaces5648
      @maplemountainfireplaces5648  4 ปีที่แล้ว +1

      Hello! You would want to check your manual for framing specs and clearances first. Then you just want to check your venting, gas line, and electrical. If your venting is flex it should be pretty easy to move but if it is hard pipe you may have to call them back to uninstall it.

    • @jrehr90
      @jrehr90 2 ปีที่แล้ว

      May be load bearing studs that prevent you from going one way or the other.

  • @JukinJiga
    @JukinJiga 4 ปีที่แล้ว

    what if i have a fireplace installed with a gas line already but no electric ignition or anything like that? I just got a home with the piping (gas) and venting already taken care of but the owners didn't have the gas logs or wiring setup. How big of a job is that? Can i do it myself or should i call a professional? Also do i need a switch like at 4:47 or can I just light the gas with a standard lighter?

    • @maplemountainfireplaces5648
      @maplemountainfireplaces5648  4 ปีที่แล้ว +1

      We don't recommend lighting the unit with a lighter or rigging anything up to the unit that has not been tested. The unit should come with some sort of ignition. The rest really depends on the brand of your unit. If it is a brand that we work with we would be happy to assist you further. We would just need pictures and the serial number. Our email is sales@maplemtnfireplace.com. If it is not a brand we work with we can help point you in the right direction.

    • @DrinkWhiskeyRaiseHell
      @DrinkWhiskeyRaiseHell 4 ปีที่แล้ว

      Sounds like you have a traditional wood burning fireplace with a gas fire starter. Different from a strictly gas fireplace like these.

  • @traceylay6106
    @traceylay6106 ปีที่แล้ว

    I need to make a comment on your galvanized pipe yeah galvanized pipe has gotten a bad rap years ago here is in 2023 well galvanized pipe has gone through a whole new process we've upgraded a whole new zinc process galvanized will not flake off zinc coating anymore so it is now allowed to use for all gas piping I've been doing gas for 45 years and now that is all I use is galvanized pipe it does not rust out like black iron do for all you black iron gas workers galvanized pipe is allowed to use in every state I hope that clears up a lot of questions on galvanized pipe

  • @kaylaharper8279
    @kaylaharper8279 ปีที่แล้ว

    Too fast.

  • @chipmulligan8963
    @chipmulligan8963 2 ปีที่แล้ว

    This guy sounds annoyed.

  • @alexlongfield2113
    @alexlongfield2113 ปีที่แล้ว

    “Just use the mill pack”… what the…? If you’re trying to help someone know what to do, then sorry but 👎👎👎

    • @onekidthere
      @onekidthere ปีที่แล้ว +1

      mil pac is the high heat sealant. It's good up to something like 1000 degrees continuous.

    • @dinojay8410
      @dinojay8410 9 หลายเดือนก่อน +1

      ​@@onekidthere ... my Mill Pac black specifies 1200° F
      The high heat RTV silicone is good to 750°F

  • @tonymarony1
    @tonymarony1 3 ปีที่แล้ว +1

    What a hack job. I have been doing this for 26 years. If you want to know, you can pay me to tell you what they did wrong. I charge 125.00/ hour, 1 hour min.

    • @dinojay8410
      @dinojay8410 9 หลายเดือนก่อน

      They practically followed the installation manual from Napoleon.