  • Bus bar protection is very much essential for a stable operation of power system. Since bus bar is the node of KCL and connects all the sources and loads together so proper isolation of faults for bus bar is essential for sable power system operation.
    Busbar protection
    Protection of bus bar
    Bus bar protection
    How bus bar is protected
    Bus bar differential protection
    over current and earth fault protection of bus bar
    Bus protection fundamentals
    Switchgear enclosure protection
    How to implement bus bar protection
    Bus bar differential protection basic concept
    Basic of bus bar differential protection
    Bus bar differential protection working principle
    Enclosure earth leakage protection
    #BusBarProtection, #ElectricalTechnologyAndIndustrialPractice, #BusBarDifferentialProtection,
    Please like, share, comment and subscribe our channel.
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 59

  • @rajchowdhury8713
    @rajchowdhury8713 3 ปีที่แล้ว +4

    Sir, your channel should have millions of subscribers. Thanks

  • @saksham9180
    @saksham9180 5 ปีที่แล้ว

    You explain thing so easily, thank you.
    Keep sharing your knowledge.

  • @bhuvneshvashishat3234
    @bhuvneshvashishat3234 4 ปีที่แล้ว

    Thank you Sir. Your method of teaching is very good.

  • @powerengr.2838
    @powerengr.2838 3 ปีที่แล้ว

    Boss.. Your method of briefing is very Excellent.. Also appreciate your Knowledge and Efforts to help needfuls.. 👍👌...

  • @mujahedasaad8753
    @mujahedasaad8753 4 ปีที่แล้ว

    Your explanation is great ... Thank you very much

  • @swaransingh1690
    @swaransingh1690 3 ปีที่แล้ว

    Nicely explained. Thank you very much sir.

  • @sharadsonawane8182
    @sharadsonawane8182 3 ปีที่แล้ว

    Sir u hav a very good knowledge. Thanks for sharing with us.

  • @TOFFYHERO
    @TOFFYHERO 2 ปีที่แล้ว

    Wowww. Thank you so much.

  • @FULLMOON36528
    @FULLMOON36528 3 ปีที่แล้ว

    Beautifully explained

  • @vipultank1819
    @vipultank1819 3 ปีที่แล้ว

    Great video. Thanks

  • @jl4703
    @jl4703 4 ปีที่แล้ว

    the explanation is very clear

  • @mohammedwail2264
    @mohammedwail2264 4 ปีที่แล้ว

    thank you for your efforts

  • @rockysubu8384
    @rockysubu8384 4 ปีที่แล้ว

    explained beautifullly

  • @surendrakverma555
    @surendrakverma555 ปีที่แล้ว

    Very good. Thanks 🙏🙏🙏🙏🙏🙏

  • @chyngyssadyrbayev6337
    @chyngyssadyrbayev6337 2 ปีที่แล้ว

    Thank u for ur job👍👍👍

  • @bharatekmauj3245
    @bharatekmauj3245 3 ปีที่แล้ว

    I love your videos.

  • @mritunjays4610
    @mritunjays4610 2 ปีที่แล้ว

    In brief, so better discussed, sir
    It's beneficial for professionals as well

  • @anthonychandachashi4480
    @anthonychandachashi4480 ปีที่แล้ว

    Crystal clear!

  • @shaikkhaja2821
    @shaikkhaja2821 5 ปีที่แล้ว

    Very good video sir

  • @jkj1459
    @jkj1459 4 ปีที่แล้ว

    VERY NICE SIR SEEMS YOU ARE WELL EXPERIENCED IN INDUSTRIAL APPLICATIONS (THOUGH LOOK STILL YOUNG ) . AND SURELY A GRADUATE FROM VERY REPUTED ENG COLLEGE ..

  • @yokeshbalajiravichandran2934
    @yokeshbalajiravichandran2934 4 ปีที่แล้ว

    excellent explanation

  • @abdullahaladawi4098
    @abdullahaladawi4098 4 ปีที่แล้ว

    Thank you very much

  • @ionraileanu6510
    @ionraileanu6510 2 ปีที่แล้ว

    EXCELLENT

  • @prasadshah3973
    @prasadshah3973 4 ปีที่แล้ว

    Hi your all videos nice and useful. I request 4 u relay testing videos. Makes....

  • @yamin3891
    @yamin3891 4 ปีที่แล้ว +1

    Best💯💯

  • @agusnugroho1042
    @agusnugroho1042 3 ปีที่แล้ว

    Good thank you

  • @seablue1085
    @seablue1085 3 ปีที่แล้ว

    Thanks, plz make more videos about protection relay

  • @Shiva68
    @Shiva68 4 ปีที่แล้ว

    Realy super

  • @shashankkumar7770
    @shashankkumar7770 3 ปีที่แล้ว

    Thanku..sir

  • @aftabraj1865
    @aftabraj1865 4 ปีที่แล้ว

    Also explain about the calculations of using protection

  • @shashankkumar7770
    @shashankkumar7770 3 ปีที่แล้ว

    Sir..Please make videos on switchgear protection settings...

  • @ebrahimali3804
    @ebrahimali3804 3 ปีที่แล้ว

    Thanks for this pretty & easy explanations!

  • @EswarDharmana
    @EswarDharmana 4 ปีที่แล้ว +1

    Pls explain the pilot wire protection scheme for two distance breakers.

  • @naveensoorajam8451
    @naveensoorajam8451 4 ปีที่แล้ว

    Sir Please do a video regarding partial busbar protection

  • @MRASIFRAZA1
    @MRASIFRAZA1 5 ปีที่แล้ว

    Sir, your video is very important to us.. Very easily we can understand... Next time Please make a video on fast bus transfer scheme....

    • @electricaltechnologyandind5335
      @electricaltechnologyandind5335  5 ปีที่แล้ว +1

      i will release a video on switchyard bus transfer shortly, after that i will make video for fast bus transfer

    • @MRASIFRAZA1
      @MRASIFRAZA1 5 ปีที่แล้ว

      @@electricaltechnologyandind5335 thanx sir..

  • @kaminichandran9610
    @kaminichandran9610 2 ปีที่แล้ว

    Helllo sir, here short circuit current rating which you have mentioned is what type of short circuit? Single phase to ground or three phase?

  • @velusamypothiraj2300
    @velusamypothiraj2300 4 ปีที่แล้ว

    Overcurrent and Earth fault setting for busbar protection, explain with calculations sir.

  • @sureshpadhy2243
    @sureshpadhy2243 3 ปีที่แล้ว

    Please explain bus differential protection scheme for one and half breaker system

  • @keshabchandratripathy7300
    @keshabchandratripathy7300 3 ปีที่แล้ว

    Respected sir
    Whether there are different time for different fault current or generally 1 sec or 0. 5sec for all fault current. How to select time for fault current i.e more current means less time. Withregards

  • @niravthakar6557
    @niravthakar6557 4 ปีที่แล้ว +1

    Very good explanation
    Pls make video on 1) BUSBAR Main zone 2 ) BUSBAR CHEK ZONE
    And pls give function of Relay 50-2 and 50-2Z

  • @muneeryou
    @muneeryou 5 ปีที่แล้ว

    Very nice video. Sir I have a question. Is the polarity of CT always such that P1 and S1 have same polarity. I checked the name plate of CT in switchyard it has no polarity mentioned like dot sign n all. So should I consider that P1 and S1 have same polarity?

    • @electricaltechnologyandind5335
      @electricaltechnologyandind5335  5 ปีที่แล้ว +2

      yes... dot sign is a text book concept. it is not employed in practical use. but p1,s1 has same polarity. the reason which i feel is that you can not make cable termination schedule with dot convention. but you can make cable schedule if p1, s1 is marked. suppose the cable shall be connected between s1 of ct 1 to terminal 1 of Relay 1, like that....

  • @jkj1459
    @jkj1459 4 ปีที่แล้ว

    IF YOU CAN MAKE A VIDEO APPLICATION OF LOCKOUT RELAY EMPLOYED IN A VCB ( IF POSSIBLE SCHNEIDER ELECTRIC VCB SWITCHING CIRCUIT . I HAVE SEEN MANY VIDEO BUT THEY ARE NOT EXPLAINING CLEAR .

  • @manojkumarpatnaikuni7552
    @manojkumarpatnaikuni7552 5 ปีที่แล้ว

    Please do video on different types of starters and how we selected that starter? like DOL, START- DELTA,SOFTSTARTER.....BREFLY.......

  • @mohamedsiraj9033
    @mohamedsiraj9033 4 ปีที่แล้ว

    hown the 51 and 51n residually connected kindly explain the connection and how it works

  • @varunlover
    @varunlover 3 ปีที่แล้ว

    Residually connected means?

  • @minakshijagwan9627
    @minakshijagwan9627 5 ปีที่แล้ว +1

    Sir, please share videos related to generator excitation & it's protections.
    Thanks

  • @mohammadpathan4668
    @mohammadpathan4668 5 ปีที่แล้ว

    Please, can you tell me which CT ratio will be applied for all three protection schemes according to your video? Thanking you and expect your valuable reply !

    • @electricaltechnologyandind5335
      @electricaltechnologyandind5335  5 ปีที่แล้ว +2

      for over current and earth fault the ct ratio shall be the maximum possible incomer currentx1.2:1A or 5 A
      same ratio for for differential ct.
      for outgoing differential ct the ratio shall be based on the outgoing current*1.2:1 or 5
      modern day differential relay does not require any ratio correction.

    • @mohammadpathan4668
      @mohammadpathan4668 5 ปีที่แล้ว

      @@electricaltechnologyandind5335 thanks a lot !

  • @aditeeraj839
    @aditeeraj839 2 ปีที่แล้ว

    At 14: 15 approx,u said that, if we maintain the ratio .......ratio of what ?

  • @lalitadeshmukh4231
    @lalitadeshmukh4231 3 ปีที่แล้ว

    Tq sir kya Hindi video provided Kar sakte ho

  • @abhinavdancy5482
    @abhinavdancy5482 4 ปีที่แล้ว

    What is 51 in there...???