How to run two generator in parallel using Deep sea controller 8610 | How to do DG synchronization

แชร์
ฝัง
  • เผยแพร่เมื่อ 8 ก.ย. 2024

ความคิดเห็น • 40

  • @oluwatosinoluwaji7044
    @oluwatosinoluwaji7044 2 ปีที่แล้ว

    Thanks for this video, it shed more light on the functionality of the DSE8610

  • @AmanYadav_np
    @AmanYadav_np ปีที่แล้ว

    Very nicely explained 👍

  • @nicowasau8673
    @nicowasau8673 2 หลายเดือนก่อน

    Thanks for the insight to the controller. Can we program 2 generators to run as Duty and Standby?

  • @SiThu-gz1bf
    @SiThu-gz1bf 2 ปีที่แล้ว

    Very helpful for me. Thank you so much.

  • @jasonhopkinson4500
    @jasonhopkinson4500 3 ปีที่แล้ว

    Really good information ,i
    Have a firm idea of synchronizing now thanks.

    • @electricalmastar
      @electricalmastar  3 ปีที่แล้ว

      Thanks for your comments and keep support us 🙏
      Thank you

  • @sr_subbureddyketha410
    @sr_subbureddyketha410 3 ปีที่แล้ว +1

    Hello very good explanation sìr
    Please send video to how saftware sir

  • @thanzeermr6595
    @thanzeermr6595 11 หลายเดือนก่อน

    Thanks for the video

  • @benzblogsVlogs
    @benzblogsVlogs 3 ปีที่แล้ว +1

    Nice job

  • @aqeelrehman5025
    @aqeelrehman5025 2 ปีที่แล้ว

    Thanks good video. Please share software setting through laptop about synchronization

  • @bishwajeetpatra1588
    @bishwajeetpatra1588 ปีที่แล้ว

    Thanks for the knowledge sharing Sir. Can i use Deep Sea Controller 8610 to synchronize DG with the Grid power? Please advice

  • @MdSalauddin-ks7rp
    @MdSalauddin-ks7rp 2 ปีที่แล้ว

    Excellent vedio. May I know if one Generator rating is 200 kVA and another one is 250 kVA then is it possible to synchronise or they must be the same rating ,can you please clarify the doubt

  • @mechatronicsautomechsaisou2400
    @mechatronicsautomechsaisou2400 3 ปีที่แล้ว

    thank you sir

  • @edwardkopondo5896
    @edwardkopondo5896 3 ปีที่แล้ว

    Thanks for the Video. Can deepsea be used to synchronise and parallel other sources of supply i.e. Solar supply , diesel generator and minihydro generator while solar being the priority source

  • @omarabood745
    @omarabood745 2 ปีที่แล้ว

    hello bro how are you hope you are doing well thanks for your good information in your videos i have question if i have two generator work in parallel by dse 8610 and one of them suddenly lose excitation from its avr then this generator will consume kvar from the second one does dse8610 detect that and prevent it as what happen in reverse power or we should put any other protection if its detect that pls explain how

  • @iancaleb6652
    @iancaleb6652 ปีที่แล้ว

    Hi, I have replaced a DSE7320 mkii with a dse 8610 on a 120kVa Genset and a 300kVa Genset with a conventional Diesel engine on both Gensets. I am trying to sync them but they are not reading the Bus voltage. Even when the bus voltage is zero, meaning the other set isn't running.
    Do I need a specific type of AVR to get it working or any type of AVR will work?

  • @nickagravante6917
    @nickagravante6917 2 ปีที่แล้ว

    Thanks ..can you teach how to set the program

  • @mdirshadmdirshad8755
    @mdirshadmdirshad8755 3 ปีที่แล้ว

    Very.very.super.explane.sab.j.hindi.mebhe.eak.vidio.banao

  • @serialupdates2330
    @serialupdates2330 3 ปีที่แล้ว

    hi can explain why should use resister in display system controller

  • @sr_subbureddyketha410
    @sr_subbureddyketha410 3 ปีที่แล้ว +1

    Hi sir can you explain how to synchronize dse program please sir????

    • @electricalmastar
      @electricalmastar  3 ปีที่แล้ว

      Thanks for your comments and for software configuration you can check this link
      th-cam.com/video/4fFWw-ArKdA/w-d-xo.html
      Thank you

  • @mauriceamollo8237
    @mauriceamollo8237 2 ปีที่แล้ว

    Is it possible to configure these controllers DSE 8610 without a laptop or software?

  • @arunsundaramoorthi8774
    @arunsundaramoorthi8774 3 ปีที่แล้ว

    Greetings,
    Thank you for the video.
    We are using Dse8610 relay, in that after synchronisation the load get swings in both DG, I mean that load balancing is in equilibrium position, that makes the any one of the DG to trip in reverse power trip.
    How to overcome this problem please advise.
    Kindly inform what is recommended trip setting for reverse power in % .

    • @electricalmastar
      @electricalmastar  3 ปีที่แล้ว +1

      Thanks for your comments and generally reverse power relay setting is 8 - 15% of generator capacity and delay time 5 seconds
      Thank you keep support our channel

    • @ashanherath2501
      @ashanherath2501 2 ปีที่แล้ว

      Adjust dg avr droop

  • @piraveenanbalasubramaniyam734
    @piraveenanbalasubramaniyam734 4 ปีที่แล้ว +1

    Hi, can you explain how to program this dse synchronous module pls??

    • @electricalmastar
      @electricalmastar  4 ปีที่แล้ว +1

      Thanks for your comments , soon i will make DG synchronization configuration video

    • @benzblogsVlogs
      @benzblogsVlogs 3 ปีที่แล้ว +2

      Yes i can explain to you

    • @mauriceamollo8237
      @mauriceamollo8237 2 ปีที่แล้ว +1

      @@benzblogsVlogs sir my biggest question here is,how to give the command to the first controller in case the government line is no more because these generators only needs to run when the government line is fail pls tell us if you have the idea

    • @benzblogsVlogs
      @benzblogsVlogs 2 ปีที่แล้ว

      Sir can clarify the context what mean by goverment i think governor you mean?

    • @RICALRONICS
      @RICALRONICS ปีที่แล้ว

      @@benzblogsVlogs grid power

  • @aldwinrichieortiz7634
    @aldwinrichieortiz7634 2 ปีที่แล้ว

    Where can i download the wiring diagram for this video.. I need clear diagram to read. Thanks

  • @ngockhuongvo2022
    @ngockhuongvo2022 2 ปีที่แล้ว

    -VE Input L - What is function? Thanks AD!

  • @mauriceamollo8237
    @mauriceamollo8237 2 ปีที่แล้ว

    Sir how is the connection between the government power and the first dg controller? Because these generators only will start working when the government line is unavailable pls am yawning to know how to command the first DG to start incase the government power is unavailable

    • @benzblogsVlogs
      @benzblogsVlogs 2 ปีที่แล้ว

      Ah ok so what you mean the commercial power if nothing or block out

    • @benzblogsVlogs
      @benzblogsVlogs 2 ปีที่แล้ว

      Just take the remote for your priority module or dg1 and connect it to your automatic transfer se for the remote command

  • @ahmedelsheikh4507
    @ahmedelsheikh4507 2 ปีที่แล้ว

    could you please attach the pdf for presentation

  • @christhawani4716
    @christhawani4716 3 ปีที่แล้ว

    Thanks for the video