Abandon Ship Drill | MV Neptune Leader

แชร์
ฝัง
  • เผยแพร่เมื่อ 10 มิ.ย. 2024
  • The content of this video depends on the muster list and contingency plan on how abandon ship drill is done onboard. In this case, the vessel is listing on the starboard side.

ความคิดเห็น • 16

  • @user-oy3xg8ln9o
    @user-oy3xg8ln9o 5 หลายเดือนก่อน

    Good Job kabaros..... stay safe always.

  • @josephvisca6639
    @josephvisca6639 ปีที่แล้ว

    Galing Captain a..Ikaw pala Ang Mando d2...Very nice

  • @jaspergonzales5659
    @jaspergonzales5659 3 หลายเดือนก่อน

    ingat tayo always kabaro

  • @tanbui1173
    @tanbui1173 ปีที่แล้ว

    THAT IS GOOD PRACTICE. TKS GUYS

  • @maungmaunglwin724
    @maungmaunglwin724 ปีที่แล้ว

    great video

  • @jaspergonzales5659
    @jaspergonzales5659 3 หลายเดือนก่อน

    nice one kabaro

  • @deddyapril9305
    @deddyapril9305 ปีที่แล้ว

    Good drill 👍

  • @AngelloDaveServidad
    @AngelloDaveServidad ปีที่แล้ว

    Galing

  • @zenithboncales1765
    @zenithboncales1765 ปีที่แล้ว

    Ask lng po diba dapat ilower muna ang lifeboat b4 sasampa ag crew?

  • @wilbertjavellana3212
    @wilbertjavellana3212 ปีที่แล้ว

    Do you have script?

  • @user-sw9hq5vi7k
    @user-sw9hq5vi7k ปีที่แล้ว

    咩國家? Which country?

  • @Rajumorcha.1979
    @Rajumorcha.1979 ปีที่แล้ว

    Good morning sir

  • @larrydwyer4168
    @larrydwyer4168 9 หลายเดือนก่อน

    ¬¬WHY ONLY OFFICERS AT THE BRIFING SHOULD BE ALL CREW.
    PRIOR TO ANY CREW JOINING A SHIP THEY SHOULD HAVE HAD SEA SERVIVAL AND FIRE TRAING.
    Correct: fire crew don scaba ( self contained breathing apparatus. yes In clean fresh air)
    Fire team should be stretching in front of them one arm out feeling for obstacles entering a smoke fill area.
    Before fireman opens door set up a water wall to prevent flash over. As room may be on fire
    Note kink in boundary cooling team hose.
    Inside the washing Machine, fire is suspected Carbonation material - meaning clothing , dry powder correct, if electrical CO2 to be used as this will not cause damage or harm to the electrical components.
    Life boat
    Why Would you install the FPD ( Fall Prevention Device ) in an emergency should be used for maintenance only, installing will Prevent the boat getting away from the falls on automatic release.
    Guy unfolding the preventer just threw it on deck, Wrong. From the flake stowage just stretch it foreword .end up
    of-course.

  • @larrydwyer4168
    @larrydwyer4168 9 หลายเดือนก่อน

    ROOKIE MISTAKE, LIFE BOAT OILS AND FUEL SHOULD BE A ROUTINE CHECK ONCE PER WEEK BY COMPETENT PERON DECK OR ENGINE ROOM MAINLY ENGINE ROOM STAFF. PERSONNEL What does competent mean in a person?
    having suitable or sufficient skill, knowledge, experience, etc., for some purpose; properly qualified: