Hi Ansari we have Morley DXC panel. we have one fault with this (LOOP OPEN CIRCUIT L1) Before one heart detector damage. we change this detector, to the same address.
Sir in this, automatically detect the panel, which sensors are conected or not? And any brand of facp detect automatically the sensors? We have the duty to edit or adress the names
Please reply for the following 1. What is the loop card concept in a addressable fire alarm system? 2. Is there any cost difference between 2 loop panel and 4 loop panel of honeywell? or technically as we have total 300 devices in our G+5 floor. Do we need 4 loop panel?
Hi Alam, mai ny addressable system ka ek video banaya h jismai almost sub explain kiya hoo Pls find below link th-cam.com/video/_6_xiGmG4CE/w-d-xo.html
Sir, how much distance should be there between two smoke detector as per standard? And for above false ceiling detector spacing will be same or different?
@@Ansari29 Sir ji . Monitor module. Jo Flow switch ke liye use Kiya hai Usme input open circuit aa rha hai.. Iskya kya solution hai.. Please help me..🙏
Bro..we have simplex 4100 semi addressble pane.zone ways connection not adress type..we have 8 lift connected befor..now one lift NC wire is missing from fire panel..so wt we do for ne NC wire for lift?
Next same Morley dxc2 address not set asper cabling it means as per cabling from panel 1,then 2 3,4 but detector address placed like from panel 2 address,1,4,3 if we install it's give any issue
We make communicate two morlay dxc4 panel each other. Fire occurs in one loop of one panel how to result of second panel and loop sounder are are coonect all system
There is one TX RX connection terminal for connecting 1 panel to other, you can simply connect & check. Meanwhile I will try to make video on said topic
98 smoke detector connect in 1 loop now I m extend one more loop and now we are 50 device divided to 2 loop now 1 loop 46 and other loop 52 But problem is before loop break and device divided so device missing error are occurs or not in 1 loop?
Sir two loop ka panel hai 1 loop sahi bta rha hai dusara loop me double address or divice fult batata hai cable ka continuity bhi check kar liya hu sab sahi hai ab kya karu jisase mera problem solve ho jaye
Hi Alam, yes bohot din sy video nhi upload kiya because kuch personal reasons sy time nhi mil pa raha hai... But jald hi videos upload hogy.... Apko kon sy topic par video chahiye... Mujhe bataye m try karta hoo...
@@Ansari29 loop Partial short, panel bhi change kar diya still same issue araa hai , double address ka bhi fault ara hai, delete ka koi option nahi hai edit hi kar sakte text wagera me, please suggest
Hii sir this side bhaigirah mujhe morley ias addressble panel ko power device se Jodna tha jisse ki fire incident hone par light of ho Jaye uske liye mujhe panel me ek no to NC point chahiye tha please help me
@@Ansari29 Thank you, in notifier panel the supervisory terminal is there.from that terminal i have to give loop between facp and repeater or any other terminal ports are there?
Aapka video bahut helpful hota hai bhai
Thank you, pls share my videos in your company group
You are doing good work. Professional work 👌
Thanks from Lahore, Pakistan
Thanks for your comments 🙂
Pls share my videos in your company group
Thank u sir
Most Awaited for this Vedio
Jzk
Your most welcome Tahir
Sir aap se ek request h ki addressbal system pe ek video banaye jis me kya kya device lagta h connection or
Yes Zaroor
Sir plz aage ka video bana kar daliye mai aap ka video ka wait karta hu ane ka
Sure Alam, thoda busy ho ek project m, jald hi new topics par video aana shru hojayega....
Thanks for your comment dear 🙂
Assalamualaikum Bhai .aap ne zone ke bare men nahi btaya zone se hi hooter bajta hai kis detector se hooter bajana hai
Detector k activate hony par NAC circuit activate hojati hai or hooter ko supply milta hai
Informative Vedio,
Can you please make a Vedio on addressable FA system with a laptop or desktop commssing.
I will try
Hooters kawn sa lagega sir kya Morley ka Loop hooter lagega
Loop hooter.... Ya fir CM k through bhi hooter ko activate kar sakty hai but best loop hooter sahi rehta hai
Hi sir sir commissioning laptop ya keypad se apan nahin kar sakte
Karsakty hai but bohot time consuming h
Bhia fire alaram.. K point ka kya charges h. Mtlb labour charhe
No idea dost...
Sir morley max par video banaye complete commissioning and troubleshooting
Ji i have one doubt?
In Est3 Panel Ct1, Ct2, Cc1 what?
Sir commission karne ke liye main menu me konsa ki pahle press karte hai
Sir mere dxc4 panel ka LOOP CARD response nahi le raha h .sab card remove karne ke baad bhi har loop ka niche wala LED hi kam kar raha b
Sir 1 loop m kitne detecter add kar sakte hain maximum
Morley m 99 detector add kar sakty h but har panel ka alag alag hota hai
Bhai mujhe batao apollo x95 panel mein addressing kaise edit karte hai. 1 vlog apollo x95 mein bhi banao Programming & Commissioning per.
Check karna padyga ....
Mera or ek sawal hai Morley me beem detector ko kaise install karte hai control module - ya monitor modul me /
Sir is Honeywell Dxc 1 Morley IAS Mai conventional hoter chal skta h
Hi Ansari we have Morley DXC panel. we have one fault with this (LOOP OPEN CIRCUIT L1) Before one heart detector damage. we change this detector, to the same address.
Aapky doubt ka video upload hogaya h please check. Pls subscribe to my channel & press the bell icon for notifications
Can you send me the video link for open loop ?@@Ansari29
super 👍
Thanks Mr.Khan
Pls share my videos in your company group
Sir comishning ke pehle detector blink nahi karte kya?
Karta hai..
MCP agar detector k bich me lagana padta hai to mcp me bhi addressing karna padega kya?
Yes, Addressable system m mcp m bhi addressing hoti hai ...
@@Ansari29 thanks
Dear .sir ...
Monitor module. Control relay module
And REPETOR Pnel ka ..commissioning kaise kare...
Or isko addressing kaise kare ....
Please bataiye
very useful and knowledgeable video ansari bhai... how to contact to for queries
Thanks, pls send your queries to ansari2991@gmail.com
Sir MSFD per ek video banau na
Ok Check karta hooo
Agar Morley fire panel me auto Learn krenge to Jo usme address h vo delt ho jyegi please btaiye
If we want to add new device in exsting system so what we have to do
Just connect that device in loop circuit & do Auto learn & then do addressing
Honywell ka frenhight series IFP2100ECS ka manual programming ka video banaeye
Yes Sure
Shudhu ok marlei hobe naki panal khule lock korte hobe
Sir in this, automatically detect the panel, which sensors are conected or not?
And any brand of facp detect automatically the sensors?
We have the duty to edit or adress the names
Please reply for the following
1. What is the loop card concept in a addressable fire alarm system?
2. Is there any cost difference between 2 loop panel and 4 loop panel of honeywell? or technically as we have total 300 devices in our G+5 floor. Do we need 4 loop panel?
1. Loop card means 1 loop circuit
2. Yes 2 & 4 loop panel have different cost.
3. More than 198 you have to install 4 loop panel
Sir kab video bana kar daliyega jo hum bole the video bana ke dalne ke liye daliye n sir plz plz jaldi se
Hi Alam, mai ny addressable system ka ek video banaya h jismai almost sub explain kiya hoo
Pls find below link
th-cam.com/video/_6_xiGmG4CE/w-d-xo.html
Sir, how much distance should be there between two smoke detector as per standard? And for above false ceiling detector spacing will be same or different?
Pls check my detector spacing video..
Can I use all Sounders in loop.....
If loop sounder then connect but before check load.
Dxc panel main loop add kaise kare?
Or comissioning me program kaise kare
Sir ji..
Monitor module ,control module
Isolator module ..ka commissioning kaise kare......
Panel me nhi aarha hai...
Auto learn karo
MCP KE NAM SE ATA HAI..
USKO CHENGE KRKE MONITOR MODULE ...MON KRNA PDA SIR JI..
@@Ansari29
Sir ji .
Monitor module.
Jo Flow switch ke liye use Kiya hai
Usme input open circuit aa rha hai..
Iskya kya solution hai..
Please help me..🙏
Bro..we have simplex 4100 semi addressble pane.zone ways connection not adress type..we have 8 lift connected befor..now one lift NC wire is missing from fire panel..so wt we do for ne NC wire for lift?
What output is generated by the smoke detector which helps panel to recognise particular address of the detector.
Alarm current
Sir mujhe smoke detector se bina connection nikale smoke detector ko kaise bypass kar sakte hai
Hello.,
can you explain difference between Dx 4c & Zx 5e.
why I should promote zx5 e then Dx
I need to check...
Sir drowning se xplane kar ke btaiye Honeywell Morley panel pe please
Laptop se nahi hota hai kya
Fire foults kese sol kar sakte hai
Pls check my fault & troubleshooting video
Hi bro your doing great job. I have dxc 2morlay panel fault showing device added. Once we lean the loop still same issue .. kindly give suggestions
Try to do autolearn
MCP mei data not available Jo fault hota ha wo kis waja say ata ha
Exactly nhi samaj aaraha hai....? What's ur panel fault
Next same Morley dxc2 address not set asper cabling it means as per cabling from panel 1,then 2 3,4 but detector address placed like from panel 2 address,1,4,3 if we install it's give any issue
Sir Siemens Fire Alarm panel K baare me Kuch Details Bataye sir please
Ok I will try to make video on said topic...
Pls share my videos in your company group
Please do SMX 4 loop panel video
Yes sure
We make communicate two morlay dxc4 panel each other. Fire occurs in one loop of one panel how to result of second panel and loop sounder are are coonect all system
There is one TX RX connection terminal for connecting 1 panel to other, you can simply connect & check. Meanwhile I will try to make video on said topic
98 smoke detector connect in 1 loop now
I m extend one more loop and now we are 50 device divided to 2 loop now 1 loop 46 and other loop 52
But problem is before loop break and device divided so device missing error are occurs or not in 1 loop?
Auto learn again, your issue will resolved
How to divice put in test mode.
Go to programming mode.check test option will be there...
Sir how to clear double address fualt.
Try auto learn 1st & then check which detector showing double address
@@Ansari29 sir Even after turning auto learning, the device is showing double address.
Sir, device level fault how this problem rectify
Detector Sensing level gets low, replace the device
Assalamu alaikum sir video bahut din ho gaya h nhi lad rahe h kab daliye ga
Ha alam bhai thoda busy chal raha hoo Isiliye video record karny ka time nhi milra
Haw to connect addressable sounder in panel dxc 2 loop
Hooter option provided
LED CARD ADDED fault shootout kese kare
Which panel
Pls sir reply jarur kariye mujhe kal panel commissioning karna hai
Dear Ansari ji,
Plz tell me for logic and pattern create
Yes, I will
Hi i am getting fault - No Reply from device R001. i am not able to find the device R001. please reply on the same
Check panel programming. R001 kisko assign Kiya hai....wo faulty ya fir disconnect hua h
if any demo with dxc-2 panel communication with usb lead cable
I will try
Is there any Institute from where i can get training&programming licesence?
Bhai fire alarm ki cv kase bane kiya ap mujey cv bana kar de saktey hai
Aapka jo bhi knowledge hai wo usmai daal dijiye..apny jis bhi fire panel p kaam kiya hai wo likh di jiye that's it
@@Ansari29 mere pass 6 saal ka experience hai notifier ka agar ap bana de tu ap ka thanks
How to make cause and effect and delay time..
Sir floor by floor hooter kse kre
Sir two loop ka panel hai 1 loop sahi bta rha hai dusara loop me double address or divice fult batata hai cable ka continuity bhi check kar liya hu sab sahi hai ab kya karu jisase mera problem solve ho jaye
Device faulty m aap device change kardo or double address k liye m aapko solution dyta hoo thoda w8 kijiye....
@@Ansari29 divice change karne par bhi double address btata hai
Honeywell notifier Id 3000 evacuate program. How to know plzz 🙏 one video for this .
Hello sir new video kab dal rahe ho bahut din se intezar kar raha hu video ana ka daliye sir plz
Hi Alam, yes bohot din sy video nhi upload kiya because kuch personal reasons sy time nhi mil pa raha hai... But jald hi videos upload hogy.... Apko kon sy topic par video chahiye... Mujhe bataye m try karta hoo...
Thik h sir
75 alaram point hor device kasa aad kra
I have faults in my device and it is not erasing. Device not resetting. Plz help
Check that fault, may be Detectors faulty
Sir aap se request ek video banai cctv camera ka installation ke bare plz
Yes Sure, I will try to make video on said topic.
Pls share my videos in your company group
Plz sir video dalo cctv camera installation ka plz
Yes Sure, thoda wait kijiye, jaisy time milyga bana k upload karuga ..
Sir full setup ke sath video bana ke daliyega installation ka video bada v jayega to koi dikkat nahi thik h sir
Dear Sir Please I hope ki aap mujhe address pattern programming zone detail me explain kigiye
I will try, I need system so that I can make a video on itm
Sir loop open circuit q dika rah h please solutions
Connfiguration fault kaise thik hota hai
How many control modules can be installed in a single loop?
In Morley 99
Whether number of modules which can be installed depends on manufacturer
Yesss... But module is sufficient to give integration...
How to rectify Duplicate address trouble
Jo bhi duplicate aaraha hai pehly usko delete karo or for new device k option m jaky add karo solve hojayega
@@Ansari29 loop Partial short, panel bhi change kar diya still same issue araa hai , double address ka bhi fault ara hai, delete ka koi option nahi hai edit hi kar sakte text wagera me, please suggest
@@sanarehman7342 make of the panel...? Pls share pic to me ansari2991@gmail.com
New detector add karne ke liye programing kaise kare
How to creat multiple zones in dxc panel
Level 3 m jaky aap loop select karky device ko zone number k hisab sy add karsakty..
Hii sir this side bhaigirah mujhe morley ias addressble panel ko power device se Jodna tha jisse ki fire incident hone par light of ho Jaye uske liye mujhe panel me ek no to NC point chahiye tha please help me
Please help for DX related.
Morley battery wiring fault and battery missing aa raha hai
Plz help me.
Thermostat ko dono battery k bech m rakho
Hello, how are you? I have an urgent question about morley dx 2 is it possible for you to help me?
Tell me your doubt..??
johan it means dear
The output voltage of each 2 loops is 11 volts, is this correct?
Sir pls tell us about how to provide power supply for FAS panel and hooters
External 24 VDV power supply
How to smoke detector delete in panel
Which panel...???
Sir output open circuit pls tell how to fix it
Dxc4 mi zone divide kaise karen
How to program Patten in dxc panel
Iss panel mein history log delete kaise karte hain please sir ??
Fire damper per video bano na
Ok I will try
If we have old panel which is working on n loop we have to add more devices can we use auto learn for new device is the old address remove or not
You can add device & do Autolearn but make sure device address should not be repeated....
Pls share my videos in your company group
Assalammu alaikkum, In facp where should i take the loop connection to repeater panel.form which terminal of the facp.
Use RS485 connection available in panel from point A & B to next panel point A & B. Use 2 core cable for it..I hope you have understood....
@@Ansari29 Thank you, in notifier panel the supervisory terminal is there.from that terminal i have to give loop between facp and repeater or any other terminal ports are there?
Morley fire alarm panel me languge change ka option kaha aata he mere fire panel me languge ka problem huwa he
how to create master panel in fire alarm system in multiple panel
There is no need to create master panel, as company already provide different model for master & slave. We just connect in terminal
Hello sir kya hal h sir Honeywell MA 8000 ki programing ki kese krta h
Loop cut open ka fault kese check krta h
Hi Bhai ji
❤❤❤
how can i use mcp conventionel with morley dxc1 plase
Reset
Restart kaise kare sir
Sensitivity level kaise set krna h smoke detector ka
Thank you Sir
How to address old panel
Can u teach me how program run in panel
Level fault kese hatay
Detector ka sensing level kam hogaya hai, pls replace asap
Please how to solve config checksum fail