ఏమి తెలియని వాళ్ళకి కూడా అర్తం అయ్యేలా చాలా బాగా చెప్తున్నారు Sir Even those who do not know what it is fire alarm system are tolding to understand Sir
Sir normal open normal close kis kis jagh pe use hoga pura details me btaye Sir apki sari video bhut informative hai thank you so much sir video bnane ke liye
Nhi...hoter ko ya toh panel sy connect Sounder circuit sy connect hota hai ya fir loop Sounder yani relay module k through external 24V DC supply sy...
@@Ansari29 thank you sir basically I am from Toronto Canada and I want learn from you if you like. Can you please share video of tool SIGA-HDT to how to remove MAP fault in EST 3 panel? Can you please share your number so I can touch with you
Sir please mujhe bataye ki ham kesa find out kre ki hamara Jo bhi device field me install hai vo proper work kr rha hai ya kharab hogya hai for example, heat detector, smoke detector, modules,kese check kre
Hi Dear, No such standard rules for cm, we install near to integrated panel. So that in future we can easily check & maintain the device. Ok i will try to make video on SLC Thanks for your comment 🙂
Sir I have a question that hooter cable loop should be separate from detectors loop or just one loop for all detector's, mcp,Hooter's and modules please reply sir.thank you
Isolator module ka use every 20th detector k baad hota hai... incase koi fault ya ground Fault ka trouble aata hai toh wo aagy ki circuit ko bypass kardyga......
Fire alarm system Secutron panel corlation kaise kare 1st.2nd.3rd floor ko lift integration karna hai mm module.cntrol module. CRM module kon lagega sir please help video
CM ka cable lift k control panel tak dy do. Lift vendor ko bolo fire hony par lift stop hona chahiye wo panel m cable connect kardyga. Aap sirf control module install karo. Only 1 or usko loop m add karo. Fire call dyky test karo NO ka NC horaha h kya..
Sir please correct me if im wrong you mean if the detectors occurs a smoke or any false alarmmed it means this monitor module will give a 24 volt output to this loads like emergency door,flow switch ? Im trying my best to visualize your videos cause i dont understant your language but still thankful hoping i got your point in this tutorial.
Ahhha now i know and i am wrong , this module is sending information into this panels to activate that every devices triggered like flow swithch and panel will alarm through bell or horns .
Not much matter but as per project we have to install it near by integrated device. Like if you want to integrate Fire panel with access control panel so better you can install near access control panel so that you can check easily it's operation & working.
I m good, mapping means u have to create zoning for some detector for some other functions like if u mapped 1st detector to 10th detector in one zone that means incase 7th detector activate then u can linked with hooter or any other integration Hope my answer clear. If you have doubt pls comment
मतलब MM फ्लो स्वीच ऐक्टीव होने की जानकारी Panel को देगा,उसके बाद Panel द्वारा CM को जानकारी भेजी जायेगी और फिर CM वहां का Alarm ऐक्टिवेट कर देगा I Am Right Or Wrong Sir ?
MM monitoring purpose use kiya jata h or CM external equipment ko control karny k liye use hota hai ..like fire alarm activate hony par access door ka open hona...
Hi, Need help! I am Sanjib Biswas and my skill set is IT Networking. Our company has collaborated with honeywell for Morley UL certification. Which is totally new to me. I had already seen all of your videos which is gave me a concept about fire panel. Please suggest me some topics for Morley UL were I can focus. Thanks,
Can you place make a deep video on class A and class B cabling system in FAS system. And in which system (addressable/Conventional) we use this cabling system
Actually sir i want say ki agr koyi default password change kar deh.. And uss password yaad na rahe toh kaise change kiya gaya password ko reset karna hain..!!!
Bhai aap ne information Galt di hai First Module is Interface with Flow switch (Monitor Module ) second Module is Interface with Emergency Exit Door (Control Relay Module) Kindly Make a correction in this Video
Thank you. Sir..No words. Bhagwan apki sarii ichha kamyab kare..
Thanks for your comment dear 🙂
Pls check my all videos, it's very useful for you.
Gjb good information bro
So nice
Aap ka sab videos bohat achha hai... Hum sab ko bohat faida hota hai aap k video se....
Thanks for your comment 😊
ఏమి తెలియని వాళ్ళకి కూడా అర్తం అయ్యేలా చాలా బాగా చెప్తున్నారు Sir
Even those who do not know what it is fire alarm system are tolding to understand Sir
Most Wellcome, pls share my videos in your company group
Its better to have sub tittle more view not only hind😊😊
Thank you 😊 very informative video
Great sir ji
Thanks Sanjeet
Pls share my videos in your company group
Excellently explained 👌
Glad it was helpful!
❤️❤️ very good sir
Thanks for your comments, pls share my videos in your company group.
best hai bahut -bahut shukriya sir aapka
Thank you, please share my videos in your company group
Very nice video
Thanks Vipul 🙂
Sir normal open normal close kis kis jagh pe use hoga pura details me btaye
Sir apki sari video bhut informative hai thank you so much sir video bnane ke liye
Ok dear, I will try to make video on this topic.
Thanks for your comment 🙂
Great Video Thanks
Most welcome
❤❤❤❤Good video..
Thanks
Good Going 👍
Thanks sir🙂
Nice explain
Thanks for your comment 🙂
Best video regarding fire modules👍👍 Can you make video on loop isolator module?
Thanks brother for your comment 🙂
Sir kya moniter model me rejistence bhi lgate hai
Thanks to you
So Good
Thanks for your comment 😊
Awesome 👍👍
Thanks for your comment 🙂
thank you for the info, sir I have question control module need seperate wire for its own power supply?
If you are connecting Hooter through CM so you need external power supply for hooter activation in fire mode.
Sir Bosch smoke detector control module lagata hai kya
Thanks sir
Most welcome, pls share my videos in your company group
Fire pump ke liye konsa module use karte hai
Good sir
Thanks for your comment 😊
Can we use one MM for wld nd vesda at a time...or need two separate
2 separate
Jharkhand se
Can we use monitor module n control module in conventional panel ??
No
Sir ji hooter monitor madual se connect rahta he na.
Nhi...hoter ko ya toh panel sy connect Sounder circuit sy connect hota hai ya fir loop Sounder yani relay module k through external 24V DC supply sy...
@@Ansari29 relay nhi Control module ke through connect hota hai
Thank you.Kindly provide vedio for water curtain system.
Sure, I will try.
If you need all about fire alarm system please subcribe my channel
Nice job and would like to know that how to identify the problem is in monitor module if faulty? Using Mini monitor module
U can just connect short link at output side. If monitoring module activated then ok otherwise faulty
@@Ansari29 thank you sir basically I am from Toronto Canada and I want learn from you if you like.
Can you please share video of tool SIGA-HDT to how to remove MAP fault in EST 3 panel?
Can you please share your number so I can touch with you
Sir please mujhe bataye ki ham kesa find out kre ki hamara Jo bhi device field me install hai vo proper work kr rha hai ya kharab hogya hai for example, heat detector, smoke detector, modules,kese check kre
Koi bhi device agar kharab hoga toh panel p uska fault aayega. Or PPM m humlog log sub check karty hai.
Sir control module or mm ko kya kam hoti hai or ise kis liye lagaye hai
Integration purpose k liye use hota hai...... CM or MM wala video achy sy dhekiye......
Nice video. Please use multimeter and show how to check earth fault practically
Ok I will try
@@Ansari29 thanks waiting for the video
If you need all about fire alarm system please subcribe my channel
Brother control module ko slc bnayenge kitna device ke baad control module lagayenge for integration
Hi Dear,
No such standard rules for cm, we install near to integrated panel. So that in future we can easily check & maintain the device.
Ok i will try to make video on SLC
Thanks for your comment 🙂
Sir I have a question that hooter cable loop should be separate from detectors loop or just one loop for all detector's, mcp,Hooter's and modules please reply sir.thank you
Depends upon panel. In some panel have separate loop NAC circuit. & in some panel it is in loop. Called loop sounder
If you need all about fire alarm system please subcribe my channel
Beam detector k baare me A to Z batayein sir, please.
I will try.
Sir which module is used to connect a conventional MCP with the Addressable Fire Alarm System. ZX2SE
Can't connect conventional MCP with addressable panel. there is one module available called zone module but i don't think so that feasible for it
Moniter model kitne type k hote hai ..sir ji
Isolator module ka kya kam hai.
Can you make video.
Isolator module ka use every 20th detector k baad hota hai... incase koi fault ya ground Fault ka trouble aata hai toh wo aagy ki circuit ko bypass kardyga......
@@Ansari29 Thanks, can you give your mobile number please
Assalamalay kum sir Est 3 smoke Control ko power supply aps panel say milthi 24V ya 230V please reply sir thanks...🤗
Abhi panel ke 230 ac voltage milti fir pane convert krke 24 volt DC current detii hai pure fire alarm system ko
@@MerajKhan-pk9hq thank you sir
Thanks Meraj👍👍👍
Hamara fire alarm system DC m work krta hai, power supply k through usy convert karty hai 230 AC to 24 DC. Power supply inbuilt hota hai
@@Ansari29 thank you sir
Fire alarm system
Secutron panel corlation kaise kare
1st.2nd.3rd floor ko lift integration karna hai mm module.cntrol module. CRM module kon lagega sir please help video
CM ka cable lift k control panel tak dy do. Lift vendor ko bolo fire hony par lift stop hona chahiye wo panel m cable connect kardyga. Aap sirf control module install karo. Only 1 or usko loop m add karo. Fire call dyky test karo NO ka NC horaha h kya..
Sir us time ka video baney jo mm install karte or phir bataeyyy ok
Brother make video on Access control system please ......
Yes sure👍
Pl inform about Arosel fire equipment
Pls check my this video
th-cam.com/video/JsziQf-KlMc/w-d-xo.html
Sir please correct me if im wrong you mean if the detectors occurs a smoke or any false alarmmed it means this monitor module will give a 24 volt output to this loads like emergency door,flow switch ? Im trying my best to visualize your videos cause i dont understant your language but still thankful hoping i got your point in this tutorial.
Monitor module is use to integrate with FAS system. Like if flow switch activate then monitor module activate & it gives signal to fire panel
Ahhha now i know and i am wrong , this module is sending information into this panels to activate that every devices triggered like flow swithch and panel will alarm through bell or horns .
Mm module kiske liye used hota hai
Please check my videos
can you please make video on Honeywell MI-DMMIE (Monitoring Module) integration wit VESDA VLF 250.
Please check my course, I have shown the wiring diagram
Hi Mr. Ansari after how many devices we install the CM and MM.
Not much matter but as per project we have to install it near by integrated device. Like if you want to integrate Fire panel with access control panel so better you can install near access control panel so that you can check easily it's operation & working.
Thanks for your comment 😊
Thanks for ur reply
masahallah
Thanks for your comment 🙂
Assalammu Alaikkum, how are you
what is mapping in fire alarm systems?
I m good, mapping means u have to create zoning for some detector for some other functions like if u mapped 1st detector to 10th detector in one zone that means incase 7th detector activate then u can linked with hooter or any other integration
Hope my answer clear.
If you have doubt pls comment
Understood brother thank you for you quick response
Ur most welcome, please share my videos in your company group.
Sir mujhe control panel ki programing or alarm system ki wiring bhi pls..
Check my this video
th-cam.com/video/_6_xiGmG4CE/w-d-xo.html
Control module kiske liye used
Please check my videos
In Fire alarm SLC circuit how much voltage flow in devices and module ?
24 VDC
Sir mere est panal me loop properly work nahi kar raha hai isolator base se age aur bypass karne pe kar raha hai kam
Exactly kya trouble aa raha hai...?
Puri loop nahi chal rahi hai bas bich ka chal raha hai
When I was doing fire alarm drawing I shown 2 numbers of monitoring module so pls explain the reason of 2 numbers mm
Bro,how it gives intimation to facp.any alarm will activate
Ye integration purpose k liye use karty hai. Jo system activate ho uska MM activate hoga or panel ko signal mil jayega..
Sir access control system ke realtive video banyaea
Yes Sure, pls share my videos in your company group
Notifire panel ka full video banaye A to z details se samjhao
Ok dear
I will try to make video on it.
Isolator module Ka Connection k bare mein ek video banaye
Connection simple hi hota hai but try karuga
❤❤❤
Thanks
What is used in resistance MM and CM?
To close the circuit
@@Ansari29 Can you explain
Lekin ye btye flow switch ko connection NO se kerye gye to monitor module ke Saath kese connect kerye gye
मतलब MM फ्लो स्वीच ऐक्टीव होने की जानकारी Panel को देगा,उसके बाद Panel द्वारा CM को जानकारी भेजी जायेगी और फिर CM वहां का Alarm ऐक्टिवेट कर देगा
I Am Right Or Wrong Sir ?
MM monitoring purpose use kiya jata h or CM external equipment ko control karny k liye use hota hai ..like fire alarm activate hony par access door ka open hona...
@@Ansari29 means cm to activate krega or mm hme btaega ki door activate hua ke nhi
Nhi...!! CM controlling purpose use hota hai, Just like a relay, ismai NO NC contact hota hai..
Or MM only monitor karta hai...
We can give 12 volts to the sir control module instead of 24k volts because my access control system is 12 volts.
Each system needs separate modules?
Yesss..
Pls share my videos in your company group
@@Ansari29 ofcource. One more doubt if we are operating lift or escalator or AHU by using control module, the module need separate 24 v supply?
No. Only Control module. It will cut the supply that's it. AHU, Lift panel damper all have this kind of terminal.
@@Ansari29 thanks bro🖒
Sir, how much pressure is on flow switch
What is ZAM Module? and its uses
Zone module....???
@@Ansari29 zone interface module like simplex ZAM MODULE
Remote indicator or response indicator detail vdo pls sir
Yes sure
Sir Isolator module how works and what is benifit and its function detail vdo pls pls pls
UPS system ke bare me bataiye
Thanks for your comment 🙂
Sir,
Input and output Module kya hai ?
Input - MM & Output -CM
@@Ansari29 Thank you very much Sir.
Please sir make the video , how to give the address to detector by excel sheet using laptop
I will try to make video on said topic
Hi,
Need help!
I am Sanjib Biswas and my skill set is IT Networking. Our company has collaborated with honeywell for Morley UL certification. Which is totally new to me. I had already seen all of your videos which is gave me a concept about fire panel. Please suggest me some topics for Morley UL were I can focus.
Thanks,
What exactly you want to learn....
@@Ansari29 As I am totally new in this domain. It is not clear to me. But as per honeywell they are going to training for Morley UL certification.
If you need all about fire alarm system please subcribe my channel
Fire alarm kayse bajta hai. Fire alarm system ka working principle kya hai?
Pls check my videos you will get good knowledge
Pump room ka video dikah do pls
Hii..sir in through control module how much voltage goes in inside the ACS panel or any integrated system it is 12 Vdc or 24 Vdc
24 VDC
Emergency panel kaise Kam karta hai
Kon sa panel....?
Ravel smoke detector ka termination bataiye sir model no- RE317D-SL
Sir guide FRM programming in notifier NFS2-3030
🙏🙏
I will try to make video on said topic..
Bhai Fire phone jack or panel की wiring byao
Can you place make a deep video on class A and class B cabling system in FAS system.
And in which system (addressable/Conventional) we use this cabling system
For Class A
th-cam.com/video/PqEcDnkN-zQ/w-d-xo.html
For class B
th-cam.com/video/_6_xiGmG4CE/w-d-xo.html
Sir how to reset system sensor two zone conventional panel
Check the trouble first & then reset
Actually sir i want say ki agr koyi default password change kar deh.. And uss password yaad na rahe toh kaise change kiya gaya password ko reset karna hain..!!!
Sir flow switch ko active kon karta?
Water k flow sy wo activate hojata h
Slowly my friend
Yes sure
Aadhi jankari
Sir supervision ka msg aata hai
👍
Thanks for your comment 🙂
Mera monitor model samajhne ke liye Mushkil Hai
Monitor module why abnormal and how rectify
Get faulty pls replace & check
sir.io modules us...kedrr.
Sir ji thoda slowly smjao
Ok brother 😊
Bhai aap ne information Galt di hai First Module is Interface with Flow switch (Monitor Module ) second Module is Interface with Emergency Exit Door (Control Relay Module)
Kindly Make a correction in this Video
Module and smoke detector Doug
I didn't get it your query
Resistance is not fixing no need resistance
Can u put in English
I will try to add subtitles in English very soon
Please speak slowly not speed u r running
Ok
Sir not clear can again explain.
.
What did you not understand....?
Where's your location???
Ooo
Yess
English Subtitle Please
Wiring diagram
Which wiring diagram
Ansari Bhai sap ki contact number dijia please
Pls send your query to ansari2991@gmail.com I will give you answer