    @ПавелДовганюк-л2в 3 หลายเดือนก่อน

    Many thanks for webinar. Just ordered Prymo 8.2.1 to my 3x Multiplus ll.

  • @MrSavage77
    @MrSavage77 2 ปีที่แล้ว +1

    I have a Victron-Fronius system…a Primo 8.2 connected to the Ac-Out of a Quattro 10k, and I’m in progress of adding a Symo 10 on the Ac-In of the Quattro. Basically the idea is to supply additional power to the house, using one phase of the Symo, and the other two phases to inject in the grid. I have a 3 phase grid. The question is
    : Do I have to connect the datamanagers of the two Fronius between them, or leave them as a standalone systems? Thanks.

    • @FroniusSolar
      @FroniusSolar  2 ปีที่แล้ว +1

      Hi MrSavage77!
      I recommend connecting the two Fronius inverters via Solar.Net. Here (www.fronius.com/~/downloads/Solar%20Energy/Quick%20Guides/SE_QG_How_to_daisy_chain_Fronius_SnapINverters_in_a_Solar_Net_communication_loop_EN.pdf) you can find instructions on that.
      If you need further help with your setup, please use our contact form:
      www.fronius.com/en/solar-energy/installers-partners/contact/support/contact-form-tsi
      Best regards, your Fronius Social Media Team

  • @ziko9762
    @ziko9762 2 ปีที่แล้ว

    Do you( Victron or fronius) have a training centre in Nigeria?

  • @dommendoza
    @dommendoza 2 ปีที่แล้ว +1

    hopefully have a low voltage on grid hybrid like 48v 3kw to 5kw. and 96v battery. for 8kw to 12kw. because I trust this brand

  • @Paul-hj1vt
    @Paul-hj1vt 27 วันที่ผ่านมา

    Why use frequency control? Why not tell the fronius over Modbus that the battery SOC is near full? And why does the Victron rely on the fronius in the first place? Isn't the Multi smart enough not to charge when the battery SOC is high?

    • @FroniusSolar
      @FroniusSolar  7 วันที่ผ่านมา

      Hello @Paul-hj1vt
      There is no direct Modbus communication, therefore the solution Victron / Fronius ist controlled via Frequency to controll the inverter behaviour.
      Best regards, Andrea from Fronius.

    • @CM9ja
      @CM9ja 2 วันที่ผ่านมา

      @@FroniusSolar Hi Andrea, my fronius 15 symo adv, still doesnt get throttled in an offgrid sitation, it just turns it off which it reboots in a few only to be shut down again, how can i go about throttling the power to match the house load and not keep thr fronius from tripping repeatedly or is that not going to harm the fronius. thank you

  • @edijsegli527
    @edijsegli527 2 ปีที่แล้ว