    🎯 Key Takeaways for quick navigation:
    00:30 🔌 Victron Energy uses a specific typology to convert DC power to AC voltage in their MultiPlus inverters and charger inverters, maintaining consistency across their product range.
    01:20 🔄 FET power bridges in Victron inverters control the output voltage by changing the switching length of FETs, achieving accurate and stable sine wave output at 20 kHz.
    03:08 ⚡ Transformers boost the low AC voltage (8-10V) generated by the inverter to standard household voltages like 230V or 120V, depending on the application.
    06:42 ↔️ Victron inverters can synchronize with the grid power supply, allowing seamless transfer of power sources and grid assistance. A relay controls the connection.
    09:56 🔄 Victron inverters can also act as battery chargers by regulating their voltage to facilitate battery charging. The charge current is controlled by adjusting the inverter voltage.

  • @tjairicciardi9747
    @tjairicciardi9747 11 วันที่ผ่านมา +1

    this is the most detailed easy to understand explanation i have ever heard, thank you

  • @mickmcgood6543
    @mickmcgood6543 5 หลายเดือนก่อน +7

    Wow what a brilliant video! I've often opened these devices and peered inside with very little idea what going on in there. I'm not an electronics technician but this was just at the right level for me to understand it. You are a very good teacher. I guess you know that all us cruising sailors love Victron. We need reliable equipment at the end of the earth.

  • @donaldpayne1376
    @donaldpayne1376 17 วันที่ผ่านมา +1

    Gidday Johannes
    Excellent explanation video. Thank you.
    I've been reccomending, installing and selling VE equipment for around 20 years and found the support excellent.
    Thank you for quality products.

  • @benveenema
    @benveenema ปีที่แล้ว +7

    So awesome that Victron took the time to do this video! Love it!

  • @karlfrederick5731
    @karlfrederick5731 5 หลายเดือนก่อน +2

    A+ Must watch for system builders. Especially explaining sizing the inverters for most efficient use. With a walk through efficiency of the FET's that make the sine wave for the inverter at 11:40

  • @fellpower
    @fellpower 6 หลายเดือนก่อน +2

    I want to live in that factory - and always walk around and see that nice things....great units Victron!

  • @rafam7365
    @rafam7365 3 หลายเดือนก่อน +1

    This is a professional and Simple esplanation. Excellent

  • @tombouie
    @tombouie 2 หลายเดือนก่อน +2

    Apparently, it comes from God, then to Johannes, & finally to everyone else.
    Yous-bes The-Man Johannes ;)

  • @danielmcleod1278
    @danielmcleod1278 4 วันที่ผ่านมา

    Excellent! Thank You

  • @nielsdaemen
    @nielsdaemen 4 หลายเดือนก่อน

    Awesome! You make the best inverters/chargers on the market!

  • @Laurel-Crowned
    @Laurel-Crowned 9 หลายเดือนก่อน +1

    Can't believe I'm bearly seeing this video!

  • @tomtinkertv730
    @tomtinkertv730 4 หลายเดือนก่อน +1

    Very cool to go so deep!
    Praise this competent presentation.
    A wish: Could you do a tech explain vidwo about the various relays in CerboGX and the 250 mppt charge controllers, please?

    • @johannesboonstra6917
      @johannesboonstra6917 4 หลายเดือนก่อน

      We just planned filming more of these indeed

  • @dogdooish
    @dogdooish 4 หลายเดือนก่อน

    great video, I use Victron for my whole house! :) :) I will be asking support some questions soon!

  • @HarukiYamamoto
    @HarukiYamamoto 4 หลายเดือนก่อน +2

    Thank you so much for this.
    Which size inverter can I use for a 136A surge current produced by a 3kW, single phase, 230V induction motor?

    • @JohannesBoonstra-ol2nz
      @JohannesBoonstra-ol2nz 4 หลายเดือนก่อน

      for a 3kW is a startup of 4-6 x the nominal power needed. Please contact the dealer for more details on models

  • @abisaiamatalo2769
    @abisaiamatalo2769 10 หลายเดือนก่อน +1

    Amazing videos. Your products look superb.

  • @gabrielbianco22
    @gabrielbianco22 5 หลายเดือนก่อน

    Que hermosa explicacion!! Muchas gracias!

  • @jelledegrande149
    @jelledegrande149 วันที่ผ่านมา +1

    mag ik zeggen: dat de Johannes dit op een eenvoudige en duidelijke wijze kan toelichten . mooi gezegd. Bent u ingenieur van beroep ? Firma's zoals Victron , die technische eigenschappen moeten uitgelegd krijgen voor het onwetende volk ivm elec. , hebben je nodig . bedankt Johannes ,

    • @JohannesBoonstra-ol2nz
      @JohannesBoonstra-ol2nz วันที่ผ่านมา

      Dank Jelle, Ontwetend is wat een groot woord, ieder zn vak zullen we maar zeggen.

  • @MP-qn1jw
    @MP-qn1jw 9 หลายเดือนก่อน +1

    My favorite product so far!! Thanks!! How does the AC sync handle an 'eco throttle' generator like a Honda 3K inverter series? When load is added, the engine RPM increases. Will this cause the AC syncs to slip? I'm in the US and use 120VAC @ 60Hz with 12V batteries.

    • @JohannesBoonstra-ol2nz
      @JohannesBoonstra-ol2nz 8 หลายเดือนก่อน +1

      there is a setting called dynamic current limiter which has a AC input level variation based on the power over a period.

  • @jimthvac100
    @jimthvac100 4 หลายเดือนก่อน +1

    which Victron inverters are Low frequency?

    • @JohannesBoonstra-ol2nz
      @JohannesBoonstra-ol2nz 4 หลายเดือนก่อน +1

      they are all hybrid, so partly HF and partly LF , mainly for isolation /robustness on peak capabilities . the RS models are all HF only

  • @jamesgor13579
    @jamesgor13579 7 หลายเดือนก่อน +1

    The symbol drawn for FETs looks more like a diode. 3:34

    • @johannesboonstra6917
      @johannesboonstra6917 7 หลายเดือนก่อน +2

      Sorry , it is a fet

    • @d.j.wiendels6572
      @d.j.wiendels6572 5 หลายเดือนก่อน +1

      the symbol drawn is a thyristor , probably mosfets are used, since they have higher efficiency, therefore stay cooler

  • @alfrednudze1791
    @alfrednudze1791 2 หลายเดือนก่อน

    Pls I have the victron and is 5000watts inverter but I want victron control charger. Pls how it cost?

  • @yuriyura2023
    @yuriyura2023 หลายเดือนก่อน

    Could you pls assist, can MultiPlus-II be configured to work the following way: load is supplied by battery/mppt in inverter mode (1 priority) if exceed the max inverter power threshold it will take extra from grid (2 priority). Saying load is 7kva, inverter is 5kva and 2 kva goes from grid? Also if load goes less than inverter power it will not export to the grid (0 is allowed). If this is possible the MultiPlus-II GX version is enough or should I purchase separate cerbo or any other equipment?

    • @JohannesBoonstra-ol2nz
      @JohannesBoonstra-ol2nz หลายเดือนก่อน

      Hello, yes this can be done with the ESS feature (with feedback disabled)
      Your dealer can help you advise in this further.

  • @jmpattillo
    @jmpattillo หลายเดือนก่อน

    Does the relay close when the inverter is turned off, so that AC power passes from the input to the output?

    • @JohannesBoonstra-ol2nz
      @JohannesBoonstra-ol2nz 25 วันที่ผ่านมา

      no, the relay opens (otherwise the inverter would be powered from shore when inactive)

    • @jmpattillo
      @jmpattillo 25 วันที่ผ่านมา

      @@JohannesBoonstra-ol2nz so you have to have the inverter on all the time when plugged into shore power?

    • @JohannesBoonstra-ol2nz
      @JohannesBoonstra-ol2nz 25 วันที่ผ่านมา +1

      @@jmpattillo yes, or select the charger only function so it will charge/passthrough when shore is available

  • @seyiadetiloye8716
    @seyiadetiloye8716 ปีที่แล้ว

    Please can I get control board

  • @sabeergo8033
    @sabeergo8033 7 หลายเดือนก่อน

    Multi plus II 12v/5000va 120 amp 230VAC? New model plz make more enquiry RV

  • @petmen71
    @petmen71 8 หลายเดือนก่อน

    domme vragen zijn er niet maar kan je ok koelen met water neem aan dat de toren warm worden???

    • @JohannesBoonstra-ol2nz
      @JohannesBoonstra-ol2nz 8 หลายเดือนก่อน +1

      In principe wel, paar daar zijn deze units (vanwege de geringe warmte ontwikkeling) niet voor gemaakt.

  • @gabaradama144k9
    @gabaradama144k9 8 หลายเดือนก่อน +2

    I’m sorry, but the guy in the background on the phone that was a little bit rude

    • @VictronEnergyBV
      @VictronEnergyBV  8 หลายเดือนก่อน +2

      It was a fully open and operational chandlery shop.

    • @gabaradama144k9
      @gabaradama144k9 8 หลายเดือนก่อน +1

      @@VictronEnergyBV yes, my friend it sure was excellent video. Excellent product whenever I get a chance to afford a split phase unit. That’s what I’m looking to buy. Thanks thanks again.

  • @bash1338
    @bash1338 ปีที่แล้ว

    Does vectron have ups mode

  •  หลายเดือนก่อน

    I want to live in that factory - and always walk around and see that nice things....great units Victron!

  •  หลายเดือนก่อน

    which Victron inverters are Low frequency?