MCB Miniature circuit breaker. Current Ratings: - it’s up to. 100 Amperes. As 0.5,1, 2, 3, 4, 6, 10, 13, 16, 20, 25, 32, 40, 50, 63 & 100 Amps. Breaking capacity 1 Pole 2, 3, 4P 1P 2, 3, 4P 6kA at 230/400VAC 6kA at 400VAC 10kA at 240/415VAC 10kA at 415VAC Trip level ------ Fixed Interrupting capacity ---- up to 10 KA Nominal voltage Ratings: - 1 P (single-pole) ~ 230/400 V 50/60 Hz 3 P (three-pole) ~ 400 V 50/60 Hz Frequency: - 50/60Hz Operating temperature: - 30C to +70C Used for Appliances: - motors, lights, AC, Water Heaters, Fridge, etc. Location of installation: - Main distribution boxes, Sub main Distribution boxes Type of Trip: - Thermal magnetic release, bimetallic strip or an electromagnet. Overload, short circuit, manually. Part of body: - incoming terminals, outgoing terminals, fix contract, moving contract, plunger, knob; Arc shutters holders, solenoid, bimetallic strip, bi-metal carrier. Note: - Tripping characteristics normally not adjustable Protection: - Short Circuit, Overloads, over currents. Installation: - Symmetrical DIN rail, Direct panel mounting, Isobar 4 pan assemblies Operate: - at less than 2.5 milliseconds during short circuit faults And 2 seconds to 2 minutes in case of overloads (depending on the level of current). Types curve: - B, C, D, E, G, K, Z Type Tripping Current Operating Time Type Tripping Current Operating Time Type B 3 To 5 time full load current 0.04 To 13 Sec Type C 5 To 10 times full load current 0.04 To 5 Sec Type D 10 To 20 times full load current 0.04 To 3 Sec Type K 8 To 12 times full load current
Video to bht acha tha sir bht smjh me v aaya. Ap MCCB pe v video bana diye or ek ye v video baniye sir ki agar hm ek ghar me 3 phase lena chate h or usko single alag alag use kare to kaise kare sir
Very informative video RCCB/ELCB ko lagane ke lia earthing karana basic requirements hai kyy house me ya Bina earthing ke phase and neutrral se trip kar jayega.
Building Construction site pe kitne AMPERE ka MCB lagega - **steel cutting machine, wood cutting machine, drill machine, vibrator etc.** Load ke liye C25 chalega kya?
Normally sar kaun sa mcb lagaya hai Jaise double TV double cooler double pankha double frige our Samar Sabule kon sa mcb lagaye taki jaldi kharab n ho.
Maine LG ka 1.5 ton Window AC liya hai (Non-Inverter) 5-star rating. Full load Cooling capacity hai 4750watt and normal power consumption hai 1415watt. Wire black 6 sq. mm hai. Electrician ne Havells ki type C32-SPN MCB install ki hai. Par aapki video mei tho C20 ya C25 tak use karne ko kaha hai. Tho ab mujhe batao kya C32 MCB sahi se kaam karegi aur mere 1.5ton AC ko protect karegi overload & short circuit se ?
718 main line wala wire kitna load uthaata hai agar 10 kw automatic stablizer connect karte hai to kya wire jal jaayegi chuki maine current me connect karne rakhi hai normally 5 to 6 ke ka ekasaath load dene par wire bahut jeet karne rahi hai pls give correct advise
Aapane is video ke last me bataya hai ki Men line dp mcb, aagar 3500 Watt lod hai to usme 25 ampiar ka dp mcb lagao lekin ham calculate kar rahe hai to 15 Ampiar Bata raha hai kripiya mujhe bataye .Mai aap ki video dekhkar he sikha hu.
Thanks for information bhai Bhai mera room per jab mai heater,, iron high load lagata hu to power socket jalke kharab hota hai kuch idea hai to bolo bhai
Too good bhai !! You are great .. Please share a video for beginners to calculate house load and how to troubleshoot " if there is voltage leaking.. " Thanks ..
1.5 HP. ke submercible pump ko challane ke liye control panel mai kitne amp. ka mcb lagana padega. abhi 16c ka mcb laga hai lekin pump chalane se wo mcb garam ho jaata hai aur control panel ka on off switch bhi jal jaata hai. Please jaldi se bataane ki kripa kare. Thanks
MCB Miniature circuit breaker.
Current Ratings: - it’s up to. 100 Amperes. As 0.5,1, 2, 3, 4, 6, 10, 13, 16, 20, 25, 32, 40, 50, 63 & 100 Amps.
Breaking capacity 1 Pole 2, 3, 4P 1P 2, 3, 4P
6kA at 230/400VAC 6kA at 400VAC 10kA at 240/415VAC 10kA at 415VAC
Trip level ------ Fixed
Interrupting capacity ---- up to 10 KA
Nominal voltage Ratings: - 1 P (single-pole) ~ 230/400 V 50/60 Hz
3 P (three-pole) ~ 400 V 50/60 Hz
Frequency: - 50/60Hz
Operating temperature: - 30C to +70C
Used for Appliances: - motors, lights, AC, Water Heaters, Fridge, etc.
Location of installation: - Main distribution boxes, Sub main Distribution boxes
Type of Trip: - Thermal magnetic release, bimetallic strip or an electromagnet. Overload, short circuit, manually.
Part of body: - incoming terminals, outgoing terminals, fix contract, moving contract, plunger, knob; Arc shutters holders, solenoid, bimetallic strip, bi-metal carrier.
Note: - Tripping characteristics normally not adjustable
Protection: - Short Circuit, Overloads, over currents.
Installation: - Symmetrical DIN rail, Direct panel mounting, Isobar 4 pan assemblies
Operate: - at less than 2.5 milliseconds during short circuit faults
And 2 seconds to 2 minutes in case of overloads (depending on the level of current).
Types curve: - B, C, D, E, G, K, Z
Type Tripping Current Operating Time
Type Tripping Current Operating Time
Type B 3 To 5 time full load current 0.04 To 13 Sec
Type C 5 To 10 times full load current 0.04 To 5 Sec
Type D 10 To 20 times full load current 0.04 To 3 Sec
Type K 8 To 12 times full load current
Kitab likh dia
Thank you very sir. I’m a house wiring electrician from Nepal. Iam very clear and certified to your wiring videos. 🥰🥰🥰
Sab log bhai ko love you kho
Muje tho MCB ke bare main sab problem dur ho gai
Love bhia love you
Thanks so much bro
बहुत अच्छा समझाएं सर
..मुझे बहुत कुछ समझ में आया इससे
जुड़ा और कुछ जानकारी हो तो अगले वीडियो में दीजिए plz
बहोत ही अच्छा बताया अपने सारा डाउट क्लियर हो गय... thankyou
Aap jo v samjhate hai bahut behtar samjhate hai
Sr aapne bahut achha tarika se samjhaya bahut acha laga 👍👍
Badiya jankari sir aisi jankari aajtak kisinebhi nahin di dhanyavad sir nice video 🙏
Bouhat achha video banya hai .biuhat kuchh sikhne ko mila
Video bahut atsha hai our amp. K bare ma Janna Cata hung
Sir g, iye video mujhe bohut pasand aya, hamesha mera man mei is tarah ka sawal ata tha.
Sir aap ka batane ka tarika aisa hai ki koi bhi samajh lega thankyou sir
Thnk you
सर आपका वीडियो मुझे बहुत अच्छा क्यों लगता है
Very Nice Video Sar
Ye vedio mere kam ka tha Sir, thanks
आपने अच्छी जानकारी दी है !
बहुत अच्छा समझाया आपने लोड निकालना भी बता दीजिए
Ok
बहुत मेहनत की आपने सर जी_ उसी तरह हमने भी पूरी वीडियो देखी ___अच्छी जानकारी दी आपने __Best of luck 👍🏻👍🏻👍🏻👍🏻
Bhut acha Se bol raha very good
Bahut bahut dhanyebad batane k liye thaink you Sr haidar ali
Thank you brother very good job
@@electricianbalaji ghnta
Video bahut achha he...nex video banaye
Very nice aur video banao MCB ke bare ghar ke kam ke liye
Bahut acha laga sab samajh aya
Thank you bhai thank you yaar very good you are welcome you are mast video👌👌👌👌
Very good explanation by EWC about all type of MCB ELCB/ RCCB. PL EXPLAIN 3 PHASE TO ONLY ONE FLAT OF 2 BHK
Ok thanks videos dekhe sir ji please aur subscribe kareth-cam.com/video/mU4tFicgg8Y/w-d-xo.html
Sir jankari dene ke liye bahut bahut Dhanyavad
Very good video .Thanks sir ❤
bohut mohtpurno information
thanks
Bahut badhiya sar 👌👍
B type MCB 10 amp ka 3 hai Agar Parallel Mein Laga De to sabse pahle kaun sa Mcb trip hoga.
Please tell me.
Video to bht acha tha sir bht smjh me v aaya.
Ap MCCB pe v video bana diye or ek ye v video baniye sir ki agar hm ek ghar me 3 phase lena chate h or usko single alag alag use kare to kaise kare sir
Excellent explanation my friend. Tks.
Bahut achhi jankari sir thanks 🙏
चेंज ओवर वीडियो बना दो भाई एमसीबी चेंज ओवर
The way you says "is video me dekhenge janenge" is amazing
😀😀😀
Very informative video
RCCB/ELCB ko lagane ke lia earthing karana basic requirements hai kyy house me ya Bina earthing ke phase and neutrral se trip kar jayega.
Earthing must
Sir aapka video kvi v mujhai lamba nhi lgta hai bcz aapka kahha hua sab baat mujhai sahi or practically proof rhta hai
Thanks
Building Construction site pe kitne AMPERE ka MCB lagega - **steel cutting machine, wood cutting machine, drill machine, vibrator etc.** Load ke liye
C25 chalega kya?
Bahut badiya bhai sahb
Achha video banaya hai sir
Mind blowing video 👌🏻👌🏻👍🏻👍🏻
Sir change over aur rccb aur mcb connection kaise lagaye
Bahut achhi bate btaye aap
Very good information sir 👍👍👍
Normally sar kaun sa mcb lagaya hai Jaise double TV double cooler double pankha double frige our Samar Sabule kon sa mcb lagaye taki jaldi kharab n ho.
Very good 👍👌 and useful information thank you so much
Thank you electric work Centre for this valuable explained.
I'ma
Good knowledge, Thanks
Maine LG ka 1.5 ton Window AC liya hai (Non-Inverter) 5-star rating. Full load Cooling capacity hai 4750watt and normal power consumption hai 1415watt. Wire black 6 sq. mm hai.
Electrician ne Havells ki type C32-SPN MCB install ki hai.
Par aapki video mei tho C20 ya C25 tak use karne ko kaha hai.
Tho ab mujhe batao kya C32 MCB sahi se kaam karegi aur mere 1.5ton AC ko protect karegi overload & short circuit se ?
Aise to chlega pr best C25 last tk hi hai compressor sef rakhne ke liye
Nice information sir thanks
Agar Ghar mai kuch kaam hai toh welding machine chalane k liye power connecting kahase de nahi toh welding machine k liye bord wairing banana sikhaiye
Namaskar bhai,pehlibath aapko "dhanyavaad",istarah ke video bananekeliye,aur aap Mccb par video banayiye bhai,dhanyavaad.
Ok thanks videos dekhe sir ji please aur subscribe kare achacha lage to comment kareth-cam.com/video/mU4tFicgg8Y/w-d-xo.html
@@electricianbalaji ghnta
#aakankshakamkaj
#aakankshahealthcareservices
#aakankshafoodie
#aakankshaelearning
#aakankshafashion
#aakankshalifeline
#aakankshasports
#aakankshaelectronicappliances
#aakankshasocialspotlight
#aakankshasocialwelfare
Nice vidio
Thank you sir Please or video daliy Mcb ke bare me lod and Amr ke bare me please sir
Very nice video👌👌👌
Sir mccb ke upar video jaruur banana
Tnk u.
Ok thanks
718 main line wala wire kitna load uthaata hai agar 10 kw automatic stablizer connect karte hai to kya wire jal jaayegi chuki maine current me connect karne rakhi hai normally 5 to 6 ke ka ekasaath load dene par wire bahut jeet karne rahi hai pls give correct advise
VERY good information
Nice vedio brother
Best explained sir ji.... power savings devices pr video banaye plz🙏🙏
One geyser one induction one water motor,one refrigerator 4 ceiling fan which one is better...mcb
Very nice make video
All clear... thank you sir👍👍
Bhai under wiring me kon kon size ka pannel box ata h full details me ek vdo.plz
Ok
2 way 4 way 6way 8way 12
किसी घरपे 50 amp कर्रेंट use होता हो तो किस टाइप का rccb लगाएं तो अच्छा रहेगा ,
B या C टाइप ?
Aapane is video ke last me bataya hai ki Men line dp mcb, aagar 3500 Watt lod hai to usme 25 ampiar ka dp mcb lagao lekin ham calculate kar rahe hai to 15 Ampiar Bata raha hai kripiya mujhe bataye .Mai aap ki video dekhkar he sikha hu.
Very good video sir ji thinks
Bhaiya 1. Q. Me
Please answer....
Kitne iqr feet m kitne 2 pol ka mcb lgta hai
Or kitne 1000
Iqr feet me kitna lod rahta hai
Ye load uper hota hai. Aap hme whatsapp pr bat kijiye. play.google.com/store/apps/details?id=apptronix.net.ewc_electricals
Thanks
Thanks for information bhai
Bhai mera room per jab mai heater,, iron high load lagata hu to power socket jalke kharab hota hai kuch idea hai to bolo bhai
Very nice information thanks
Very very nice 👌
Bahut sahi sir ji
Very good advice sir 👍👍👍👍👍
Too good bhai !! You are great .. Please share a video for beginners to calculate house load and how to troubleshoot " if there is voltage leaking.. " Thanks ..
Excellent explanation. Tks.
thanks man for the help☺
Sir 3 fes wairing me kya lgaye
Jisase 1 fes band ho jane par
Ato mitik Dusre fes se chalu
Ho jaiga
Harsh Sahu ratiri lagay
Sir mujhe 5 selig fan and 3 Colar 2freze and 12 led balb jalana hai sir ketane ka mcb lagega
Bro ac me double poll ki mcb lagaye ya single poll agar double poll lagaye to kitne ampr mcb lagaye. Only ac me
Please video fror mccb . I like your video
Ok
440 what ghar ki main supply me kon si mcb lagani chahye jo ki shot circuit hone par trip kar jaaye kirpya reply kare
Bahut badhiya sir
Wese sar zi aap appughe zante nahi hame aap se bahut payar he
Sir ap jo bole h 6000w me B,40 lagega.
Par yaha pe 6000/220= 27.27 ampere ho raha h.
Please reply me fast sir
So what?
Very nice video
Kyaa ham 1.5 ton AC mai C40 MCB use karsakte h
PLZZ reply
Good brother acha lagga
bhai me HITBOX MIG 200a welding machine use kar raha hun tu kaun sa tu lagau
Very good video sir
Thanks Bhai good information
1.5 HP. ke submercible pump ko challane ke liye control panel mai kitne amp. ka mcb lagana padega. abhi 16c ka mcb laga hai lekin pump chalane se wo mcb garam ho jaata hai aur control panel ka on off switch bhi jal jaata hai. Please jaldi se bataane ki kripa kare. Thanks
Bhaiya 2200 watt Hiter chalane liye konsa MCB lagay
Very good 👍
Please make a video in MCCB and panel board with change over. MCCB with 200 amp ka load kya hai?
Ok thoda smy lgega
Ok thanks videos dekhe sir ji please aur subscribe kare achacha lage to comment kareth-cam.com/video/mU4tFicgg8Y/w-d-xo.html
Ap ka video muja bbbbb aich
Super video sir
Agar hum singal fes ka house waring karte hai to isme mcb lagaye ya lcb pliz