Liquid Penetrant Testing

แชร์
ฝัง

ความคิดเห็น • 96

  • @abc6312
    @abc6312 ปีที่แล้ว +11

    If provide more close-up pictures for all indications on the second test plate, it will be great.

  • @writer1meb
    @writer1meb 7 ปีที่แล้ว +4

    Thank you. This video is very helpful. We didn`t know before watching this video how to use liquids.

  • @arvindnavinsv2227
    @arvindnavinsv2227 3 ปีที่แล้ว +3

    thanks man you did a great job explaining, i am gonna show this to my student for easy understanding

  • @sv7382
    @sv7382 9 ปีที่แล้ว +1

    Great demonstration Robert. Mike told me the story behind the test plate. Sneaky!

  • @dan-xl4mg
    @dan-xl4mg 3 ปีที่แล้ว +18

    this is so much easier to understand then my teachers explains it in front of 30 students, so thank you for this amazing video, I will definitely recommend this to the other students.

  • @georgevitor6975
    @georgevitor6975 3 ปีที่แล้ว

    After mechanical cleaning ( example wire brushing,grinding,buffing) of part to be tested,is cleaning of part by means of cleaner/remover still necessary?or it can be skipped and apply penetrant already?

  • @wizyasilupumbwe2497
    @wizyasilupumbwe2497 7 ปีที่แล้ว +1

    thanks am actually writing an end of term essay on this, cleared alot of things up thanks.

  • @kmondak3387
    @kmondak3387 8 ปีที่แล้ว +8

    Should have tilted the plate to do away with glare and let the viewer see. An intentional crack in the plate would have been good for checking engine heads etc.

  • @kalpeshsingh2670
    @kalpeshsingh2670 3 ปีที่แล้ว

    How to find out the length of a circular defect whose end is loose? as in not connected?

  • @FacetiousUniqueness
    @FacetiousUniqueness 7 ปีที่แล้ว

    Excellent Video! Thanks!

  • @marcodiegocambronerovillal7647
    @marcodiegocambronerovillal7647 3 ปีที่แล้ว +9

    Me studying, getting asmr vibes from this lmao

  • @nathanbra8605
    @nathanbra8605 3 หลายเดือนก่อน

    If you spray a paint brush with penetrate and brush weld, will that decrease results or is that ok?

  • @ptrangdang
    @ptrangdang 7 ปีที่แล้ว +2

    very clear. well-done. thank you

  • @DPeter1967
    @DPeter1967 9 ปีที่แล้ว

    Great Jog Robert! Haven't seen you since the New Bay Bridge Project.

  • @adilhafeez5942
    @adilhafeez5942 4 ปีที่แล้ว

    Really good explanation thx

  • @finessedagain4557
    @finessedagain4557 4 ปีที่แล้ว +1

    You are an absolutely legend, I hope you know that pal

  • @muhammadahsanmehar3265
    @muhammadahsanmehar3265 4 ปีที่แล้ว

    Why we are not use to cleaner direct sprey in welding .

  • @rubenrosales7823
    @rubenrosales7823 4 ปีที่แล้ว

    Close up of defects?

  • @jjjsss3869
    @jjjsss3869 8 ปีที่แล้ว +27

    A close up of the plate with the defects so we could actually see what they look like would have been helpful.

  • @brettb.7425
    @brettb.7425 5 ปีที่แล้ว +1

    Good demonstration but please get the camera closer to show the details. Thank you for posting this!

  • @jithinmathewjoseph9465
    @jithinmathewjoseph9465 4 ปีที่แล้ว

    can this method be used in pipes

  • @planetbeatmobb1762
    @planetbeatmobb1762 8 ปีที่แล้ว +8

    great job, we were taught to spray the developer away from the metal first to make sure it's fully agitated tho?

    • @ifaheemonline
      @ifaheemonline 8 ปีที่แล้ว

      +Planet Beat Mobb Yes you are right. it ensures the uniform spray of developer.

  • @ezekielmunatsi5496
    @ezekielmunatsi5496 2 ปีที่แล้ว

    Very informative, Thank you.

  • @dishitapurohit2478
    @dishitapurohit2478 8 ปีที่แล้ว +3

    Can you provide with the product name and specifications of the red spray dye and cleaning sprays you used? also can this be used to test for solders on PC boards

    • @robertmertz7544
      @robertmertz7544 8 ปีที่แล้ว

      +Dishita PUROHIT I would recommend using RT for PC boards.

  • @socialhelp5704
    @socialhelp5704 5 ปีที่แล้ว +1

    removing pen
    etrant is only in one direction ... To and fro is not allowed

  • @ryanarnold2813
    @ryanarnold2813 7 ปีที่แล้ว

    Very Nice, Well Done !

  • @tradingmachine65
    @tradingmachine65 2 ปีที่แล้ว

    make sure cleaner flashes off for correct time, 5 minutes min. old cleaners used to flash much faster. if cleaner remains in crack, inspection is void, if being audited you'll be flagged

  • @nomuplays7487
    @nomuplays7487 3 หลายเดือนก่อน

    Why u did to and fro motion which doing solvent removal? It's clearly written in ASME BPVC SEC 5 ARTICLE 6

  • @yuvrajbhatt1050
    @yuvrajbhatt1050 6 ปีที่แล้ว +3

    It was nice illustration of the whole process. Can u tell which cleaner, dye & developer you used here?

    • @prasadsawant1213
      @prasadsawant1213 3 ปีที่แล้ว +1

      Pmet is one the oldest and leading companies.
      Different products available as per different sizes of cracks

  • @abidsaleemdesconian3528
    @abidsaleemdesconian3528 3 ปีที่แล้ว

    Thanks for fine explaination.

  • @akkusrocks3367
    @akkusrocks3367 4 หลายเดือนก่อน

    Sir penetrant cleaning need to do in one direction , am i right ?

  • @The3Shogun
    @The3Shogun 8 ปีที่แล้ว +16

    You must wipe off pentrant vertically or horizontally only. One direction. And way to much developer on your HAZ.

    • @robertmertz7544
      @robertmertz7544 8 ปีที่แล้ว +3

      +The3Shogun You are correct for most PT applications regarding cleaning. I disagree about the HAZ. I suppose I could have masked the area of base metal that was not under inspection but the developer spray covers a large area and cleans off very easy. The procedure I was following allows me to wipe in both directions and as indicated I won't have a lot of non-relevant indications that need to be re-tested. Also, the weld and HAZ are evaluated based on VT after PT so I can wipe penetrant out of U/C, etc. and measure for acceptance. Cracks that are very tight would not be wiped away but may be missed by VT. I could have explained why I was cleaning in both directions. Thanks for the feedback.

  • @Gabby-du4mc
    @Gabby-du4mc 6 ปีที่แล้ว

    Thank you!!

  • @crackersphdinwumbology2831
    @crackersphdinwumbology2831 6 ปีที่แล้ว +1

    I'm an Air Force NDI technician.
    It's kind of shocking how similar yet different Method C inspections are in the civilian sector. Only 20 minutes of dwell time only using visible dye penetrant! It makes sense though, given its easier, faster, and it's doubtful you need as much sensitivity.

    • @subinperingave9777
      @subinperingave9777 6 ปีที่แล้ว

      Hi..
      I have a doubt.
      Is there any need to do penetrate test on a complete machining part ?

    • @chuckb9595
      @chuckb9595 2 ปีที่แล้ว

      That was only 10 min of dwell time.

  • @malikahmad781
    @malikahmad781 5 ปีที่แล้ว

    superb video

  • @raymonddupuis9461
    @raymonddupuis9461 9 ปีที่แล้ว

    Nice video moderately informal though....

  • @riddhisarvaiya5243
    @riddhisarvaiya5243 6 ปีที่แล้ว

    You should clean the plate in one direction. And also apply penetrant and developer in one direction. It is either horizontally or vertically. Not both direction you can use for perfect results.

    • @newmovieschannel1364
      @newmovieschannel1364 6 ปีที่แล้ว

      ya mam absoultly write ...he is not correct because of pentrates also pick out in defects

    • @newmovieschannel1364
      @newmovieschannel1364 6 ปีที่แล้ว

      ya mam absoultly write ...he is not correct because of pentrates also pick out in defects

    • @razvancampean
      @razvancampean 5 ปีที่แล้ว

      can you specify where does it say so? in which standard or norm (what page)?

  • @tanveerahmed3094
    @tanveerahmed3094 7 ปีที่แล้ว +1

    thanks very helpful.

  • @shanwarn3772
    @shanwarn3772 6 ปีที่แล้ว +7

    Hi sir
    good morning
    I'm from india
    i finished NDT Level 2
    i need a job
    did any vacancy is in your factor

  • @hahaclintondix6099
    @hahaclintondix6099 2 ปีที่แล้ว

    This is definitely Walter white Heisenberg

  • @victornjoku9684
    @victornjoku9684 ปีที่แล้ว

    Why cleaning zig-zag.,? Clean from one side.

  • @yacinebenz1349
    @yacinebenz1349 9 ปีที่แล้ว

    great job

  • @hectorpaniagua5702
    @hectorpaniagua5702 6 ปีที่แล้ว

    What method is this

    • @spoonbill01
      @spoonbill01 6 ปีที่แล้ว

      Hector Paniagua This is Type 2 (visible ) Method c ( solvent removeable ) Form e ( nonaqueous type 2 visible dye solvent based ) Class 2 solvent ( non-halogenated )

  • @ar-1571
    @ar-1571 ปีที่แล้ว +1

    Great video! My teacher played this during class and me and my friends laughed at this because you made it look like a Porn video.. I mean the way you were breathing and cleaning 🤣🤣

  • @imanebahar286
    @imanebahar286 4 ปีที่แล้ว

    great video

  • @givenmahlangu1266
    @givenmahlangu1266 5 ปีที่แล้ว

    Is Post cleaning necessary ?

    • @rubenrosales7823
      @rubenrosales7823 4 ปีที่แล้ว

      Given Mahlangu depends where you are and who you are working for. My preference is to leave clean, unless there are any relevant indications. If there is a defect that is Rejectable I mark up and leave so the welder/QC or whoever is the one you are reporting to may see... I have worked places where they are big on us leaving it clean and also have been places where they just go to next job/weld...

  • @abdelwahedbanouji2638
    @abdelwahedbanouji2638 8 ปีที่แล้ว

    i wanna learn the liquid penetrant teasting cuz im a radio log i wanna some info about that and i wish if someone contac me for ask him meny thing about liquid and magnet

  • @shreeramvenkatesan1658
    @shreeramvenkatesan1658 4 ปีที่แล้ว

    This guy is really really cool

  • @adamismail9895
    @adamismail9895 8 ปีที่แล้ว

    super

  • @samueljacob6031
    @samueljacob6031 5 ปีที่แล้ว

    thank you sir

  • @user-zf4ov2rs1g
    @user-zf4ov2rs1g 3 ปีที่แล้ว

    معهد النجف 😎 يرحب بكم

  • @srinivasandwarakanathan3822
    @srinivasandwarakanathan3822 ปีที่แล้ว +1

    Well explained, But as per standard practice while applying , cleaning pentetrant from the surface we should not wipe or clean bi-directionally. It shall be cleaned only in one direction, the same is applicable while applying penetrant. Hope i am correct.
    Regards
    Dwarakanathan ASNT LEVEL III

  • @3sempravin.r13
    @3sempravin.r13 หลายเดือนก่อน

    It's cleaning process is not accepted

  • @narendernayakguguloth5018
    @narendernayakguguloth5018 6 ปีที่แล้ว

    Tq sir

  • @brianb5779
    @brianb5779 2 ปีที่แล้ว

    Camera guy afraid to get close. Otherwise good info

  • @esmeraldaalviso2220
    @esmeraldaalviso2220 2 ปีที่แล้ว

    I didn't like it cause a indication in the plate will be better explanation.

  • @sneakpeek7767
    @sneakpeek7767 2 ปีที่แล้ว

    Keep doing

  • @itsimzaa621
    @itsimzaa621 ปีที่แล้ว

    Will the fluorescent non-aqueous developer produce better results in evaluating the defects than the visible non-aqueous developer?

  • @rmvmedia4897
    @rmvmedia4897 5 ปีที่แล้ว +1

    Wrong apply method

  • @kuranenuhaa1880
    @kuranenuhaa1880 2 ปีที่แล้ว

    Well Explained. Thank you sir, please can u list some examples of the liquid penetrant commonly used

    • @chibuzorsabinus4178
      @chibuzorsabinus4178 ปีที่แล้ว

      Very interesting and well explained. Thank you sir

  • @redcarpet2544
    @redcarpet2544 2 ปีที่แล้ว

    Hello! Thanks for useful video! I have the only one question...Why don't you use a respirator? These sprays are extremely harmful for your health, especially for lungs.

  • @chanthasavann
    @chanthasavann 4 ปีที่แล้ว

    Hello Guy let mark your Friend too

  • @fahdhanif4150
    @fahdhanif4150 3 ปีที่แล้ว

    Watching this just for exam purposes 😑😑😑

  • @mood666
    @mood666 ปีที่แล้ว

    6:00

  • @bn70066
    @bn70066 9 ปีที่แล้ว

    hi am NDE man from middle east :))

  • @saqarjamel3383
    @saqarjamel3383 6 ปีที่แล้ว

    Goog

  • @TheAjnett23
    @TheAjnett23 5 ปีที่แล้ว

    your camera man/women is not so very good..

  • @somnathghosh9873
    @somnathghosh9873 9 ปีที่แล้ว

    Post cleaning is not proper Way..

    • @JavierD
      @JavierD 9 ปีที่แล้ว +1

      Somnath Ghosh why?

    • @somnathghosh9873
      @somnathghosh9873 9 ปีที่แล้ว

      for post cleaning you must clean the surface, from first point to 2nd point you can't clean first to 2nd and again 2nd to 1st. you can clean any of one way 1st to 2nd or 2nd to 1st jv071

    • @chevellecarcass
      @chevellecarcass 9 ปีที่แล้ว

      Somnath Ghosh Post cleaning after the penetrant is applied? What do you mean by 1st to 2nd?

    • @JavierD
      @JavierD 9 ปีที่แล้ว

      ***** 1st point to 2nd point. What Somnath state is that one should clean in the same direction, always right to left (for example)

    • @somnathghosh9873
      @somnathghosh9873 9 ปีที่แล้ว

      yaa you are right

  • @user-bm1jt1jz4o
    @user-bm1jt1jz4o 2 ปีที่แล้ว

    CovidImages need to be invested more than half19