floatless level switch connection | high and low water tank control | Electreca

แชร์
ฝัง
  • เผยแพร่เมื่อ 15 ต.ค. 2024

ความคิดเห็น • 23

  • @abassembatya
    @abassembatya 2 ปีที่แล้ว +1

    Thanks for the educational videos David. We really appreciate,
    I request that for such videos of circuits and connections, I request and suggest that for each pin that you connect, you say it out loud so that we don't get left behind.
    Some of these components are new to us.
    Thanks again.

    • @electreca1
      @electreca1  2 ปีที่แล้ว +1

      Understood! Thanks for watching

  • @kaundabwalya7776
    @kaundabwalya7776 หลายเดือนก่อน

    Well explained Sir 👍 God bless you 🙏

  • @hajimuhammad2928
    @hajimuhammad2928 2 ปีที่แล้ว

    Thank You Very Much, Sir.
    Kind Regards
    From, Karachi, Pakistan

  • @mayeelect
    @mayeelect 2 ปีที่แล้ว

    Thank you so much for contribution to knowledge. Please I have questions: what type of electrode is used in the connection, is it normal Earth electrode? 2. Would the water in the tank not carry current that can get one electrocuted? Thanks in advance for answering the questions.

    • @electreca1
      @electreca1  2 ปีที่แล้ว

      Earth electrode tends to be long and naked(not insulated).
      But for float less are called PROBE. They have insulated almost 3 quoters of their length and only a tiny tip is exposed.
      There is definitely a leakage in the tank, But as I said in the video, Electrode No3 is Earthed.
      When you Earth there will be no leakage completely
      Thanks for watching

  • @davechesney7721
    @davechesney7721 2 ปีที่แล้ว

    Great videos just what I was looking for.
    In a water tank do you use a wire with a bare end, as you used in the demonstration, or is there something specific available.
    A quick search online didn't come up with anything her in Thailand.
    Many thanks Dave

    • @electreca1
      @electreca1  2 ปีที่แล้ว +1

      Thank for watching, there are deferent types of probes take look s.click.aliexpress.com/e/_DkQTcXN This can do.

    • @davechesney7721
      @davechesney7721 2 ปีที่แล้ว

      Thanks for your prompt reply.
      I will look for those on the local equivalent of Ali Express
      I did find what Omron call eletrodes ,stainless steel rods.
      I think that I will use a float switch when we install the water tank.
      Thanks Dave.

  • @86benjah
    @86benjah 2 ปีที่แล้ว

    Quick question assuming the two bulbs are pumps will it drain and fill the tank without you rewiring the circuit?

    • @electreca1
      @electreca1  2 ปีที่แล้ว

      Yes

    • @abassembatya
      @abassembatya 2 ปีที่แล้ว

      Replace the bulbs with the contactor coils of the respective pumps.

  • @rawlingsnuweaha3838
    @rawlingsnuweaha3838 7 หลายเดือนก่อน

    Hi
    For the nc connection,when it reaches e1 the relay becomes on /off like that until you switch it off

  • @itsok2902
    @itsok2902 ปีที่แล้ว

    U are my best

  • @mohamedqadar4478
    @mohamedqadar4478 2 ปีที่แล้ว

    I would like to have your contact to learn somethings from you.thanks

  • @mathewsnyirenda4004
    @mathewsnyirenda4004 ปีที่แล้ว

    So all the 3 probes have to go in the borehole?

    • @electreca1
      @electreca1  ปีที่แล้ว

      Yes< But set at deferent hights

  • @linossinkala7840
    @linossinkala7840 2 ปีที่แล้ว

    Super super thankyou sir

  • @dennisimujaro512
    @dennisimujaro512 ปีที่แล้ว

    What if I short all the electrodes during drain or fill

  • @otengamponsah6034
    @otengamponsah6034 2 ปีที่แล้ว

    How can I get some of the level switch to buy

    • @electreca1
      @electreca1  2 ปีที่แล้ว

      They are widly sold localy but you can get them on Aliexpress

  • @gamelover2594
    @gamelover2594 2 ปีที่แล้ว

    nice video, pleasure to look at your video

  • @ErnestAsodio-ir4ks
    @ErnestAsodio-ir4ks ปีที่แล้ว

    Thanks big man, I just request for your number. Thank you