Plate

แชร์
ฝัง
  • เผยแพร่เมื่อ 29 ส.ค. 2024
  • #Chilledwater #Coolingsystem #Butterflyvalve #automaticairrelief
    Subscribe Now www.youtube.com...
    Here are more Interesting video about HVAC System, Please have a look.
    #Ducting for Bigger Area along with VAV & VCD, Adjusting Flow Rate L/s as per Area with Eng Sub/CC • #Ducting for Bigger Ar...
    #VAV Controlling with Thermostat & BMS System along with Occupancy Sensor Wiring with DDC Eng Sub/CC • #VAV Controlling with ...
    What's ETS Room? What are the Equipment's Inside & their Purpose? Chilled Water Pipe line Network. • #ETSRoom What are Equ...
    Chilled Water #PressurizationUnit |Explanation about #PressureSwitch & #PressureVesselTank • Chilled Water #Pressur...
    Plate #HeatExchanger in the #DistrictCoolingSystem Primary & Secondary Pipe line Purpose/Working All • Plate #HeatExchanger i...
    Chilled Water Automatic & Manual Chemical Dosing System in the District Cooling System full Detail • Chilled Water Automati...
    FAHU|Exhaust Air & Supply Air System|Heat Recovery Wheel|Filter Types|Cooling Coil| Air Blower| • FAHU | Fresh Air & Exh...
    Air Handling Unit works |Different Types of Filters|Chilled Water System Along with Temp&Pressure| • Air Handling Unit work...
    Chilled Water #PressurizationUnit |Explanation about #PressureSwitch & #PressureVesselTank • Chilled Water #Pressur...
    HVAC Chilled Water Pumping System|Controlling of CHW Flow|Pipping#Strainer Motor Plate Info #ETSRoom • HVAC Chilled Water Pum...
    Actuator/Motorized Valve|Wiring|Connection|Working|1way&2Way|Manually Control| BMS Control | • Actuator/Motorized Val...
    How does Thermostat works, Connection, Addressing and Operation Full Detail • How does Thermostat wo...
    BMS Control Panel which apply to FCU, How Devices are been wired & DDC Card Full Detail • BMS Control Panel whic...
    Differential Pressure Transmitter/Air Velocity meter Working Principle, Installation & Wiring Detail • Differential Pressure ...
    BTU Meter/Water flow meter/Temperature meter their units of measure/Installation/Connection all here • BTU Meter/Water flow m...
    Explanation about Fan Coil Unit, FCU parts, Actuator and DRV Valve with English Substiles • Explanation about Fan ...

ความคิดเห็น • 33

  • @HBTV2020
    @HBTV2020  3 ปีที่แล้ว +1

    Thanks for Watching !
    Please like & Share !
    Please Support me by Subscribing my Channel
    th-cam.com/users/hbtv2020

  • @raiannurislam
    @raiannurislam 4 หลายเดือนก่อน

    very informative

  • @tariqueselfie0787
    @tariqueselfie0787 6 หลายเดือนก่อน

    Sir please explain air cooled chiller and primary pump, second pump.

  • @faizeee970
    @faizeee970 5 หลายเดือนก่อน

    What is the source of the water that gets supplied to the building (building cooling loop) ?

  • @sohailansari8385
    @sohailansari8385 6 หลายเดือนก่อน

    ETS ka SACAD display k bare m video chahiya please

  • @faizeee970
    @faizeee970 5 หลายเดือนก่อน

    Secondary side water to building kidar se supply hote… please reply

  • @mohdakramsaifi925
    @mohdakramsaifi925 ปีที่แล้ว

    Topic tha plate heat exchanger or bna diya accessories pr

  • @mdmohi5635
    @mdmohi5635 7 หลายเดือนก่อน

    Zabardast vedio hai

  • @ZahidKhan-jp3zb
    @ZahidKhan-jp3zb 10 หลายเดือนก่อน

    Secondary line ka out temperature kese control krte hai

  • @vipulhodawdekar7541
    @vipulhodawdekar7541 3 ปีที่แล้ว +1

    what there is chilled water HE . Normally chilled water from chillers directly go to AHUs .Why there is a heat exchanger in between?

    • @HBTV2020
      @HBTV2020  3 ปีที่แล้ว +2

      The chilled water has been provided by a outside company they having very big cooling tower and chiller station for big Island
      The purpose of the heat exchanger that consumer can maintain their own temperature in the building and service provider can maintain their standard temperature and it will help to calculate the consumption

    • @HBTV2020
      @HBTV2020  3 ปีที่แล้ว +2

      Consumer has to maintain particular Delta T otherwise service provider can fine the consumer because its effect their plant efficiency
      And if consumer by mistakenly made bigger change to their system secondary side it will not immediate effect on service provider company

  • @nadimakram941
    @nadimakram941 2 ปีที่แล้ว

    Sir, Heat exchanger kaise kaam karta hai District cooling tower ya Chiiller se jo child water supply aata hai to uska Temperature ko HE kaise maintain karta hai, as per requirement ??
    Sir, please reply!

  • @mirreazuddin5968
    @mirreazuddin5968 ปีที่แล้ว

    Bhai hitexchanger pipe kon konsa pipe ka sat canektion hora ohi bata digiya

  • @mohdaijaz7292
    @mohdaijaz7292 3 ปีที่แล้ว

    how primary side flushing done, their is no bypass observed in the video.?

  • @gulabrbbani2261
    @gulabrbbani2261 3 ปีที่แล้ว

    Jo water aaraha hai heat exchanger me o v to cool water h m.to direct floor me nahi bhej sakte hai

  • @Toptech.24
    @Toptech.24 ปีที่แล้ว

    HMI display me koi bhi Parameter show nhi kr raha hai,mujhe kya setting krne chahiye, please reply

  • @Toptech.24
    @Toptech.24 ปีที่แล้ว

    Sir ,mera ETS room ka ek pump trip kar gya tha iske liye maine ,main incomer se manually reset kar diya lekin koi bhi pump auto mode me karne pe koi bhi pump run nhi kar raha hai ,or HMI ke display me ,: (Failed to open connection to PLC
    ModbusEquipment01) Aisa error aa raha hai

  • @gulabrbbani2261
    @gulabrbbani2261 3 ปีที่แล้ว

    Ye water direct floor me or mall me nahi de sakte hai

  • @sakdasaosa9746
    @sakdasaosa9746 ปีที่แล้ว

    How to control flow & delta t in system?

  • @vipulhodawdekar7541
    @vipulhodawdekar7541 3 ปีที่แล้ว

    Sir also inlet of Plate HE is 5degree from cooling tower.Sir cooling tower se itna chilled water how it is coming.May be it is from chillers.Please can you clarify on this??

    • @HBTV2020
      @HBTV2020  3 ปีที่แล้ว +1

      In cooling tower water get cold with two different ways
      first water pass through form cooling tower rejected heat in the atmosphere than it pass through from chillers (chiller evaporator section) which decrease more water temperature then it distributed to the different project
      Even it is possible to gain even 1 Degree Celsius water temperature from cooling tower
      Since cooling Tower receive return chilled water temperature approximately 16 degree which can be reduced into 5 degree Celsius by air cool only
      if outside temperature too high or high Relative humidity level then they use chiller to lower down the temperature of chilled water

    • @mdaadilfiroz3525
      @mdaadilfiroz3525 3 ปีที่แล้ว

      PHE mai water chiller se ata ha district cooling plant se

    • @HBTV2020
      @HBTV2020  3 ปีที่แล้ว

      @@mdaadilfiroz3525 Districting cooling plant se agar building k apne chiller hon to HEX ni lagaty

  • @gulabrbbani2261
    @gulabrbbani2261 3 ปีที่แล้ว

    Ye heat ko kaise exchange karta hai..ye water return ho Kar kha kaja h

    • @HBTV2020
      @HBTV2020  3 ปีที่แล้ว

      th-cam.com/video/eElxiJi1pLw/w-d-xo.html
      Is video ko Dekhen ismein Tamam information mojud hai aur heat exchangers related

    • @gulabrbbani2261
      @gulabrbbani2261 3 ปีที่แล้ว

      @@HBTV2020 is video ko dekh Chuka hu Bhaizan..waise fir se dekh leta hu

  • @gulabrbbani2261
    @gulabrbbani2261 3 ปีที่แล้ว

    Haet exchanger lagane ka Kya faida h

    • @HBTV2020
      @HBTV2020  3 ปีที่แล้ว +1

      The chilled water has been provided by a outside company they having very big cooling tower and chiller station for big Island
      The purpose of the heat exchanger that consumer can maintain their own temperature in the building and service provider can maintain their standard temperature and it will help to calculate the consumptio

    • @gulabrbbani2261
      @gulabrbbani2261 3 ปีที่แล้ว

      @@HBTV2020 thanks

  • @gulabrbbani2261
    @gulabrbbani2261 3 ปีที่แล้ว

    Please answer my question

  • @mohdakramsaifi925
    @mohdakramsaifi925 ปีที่แล้ว

    Time wasting video