Which Hp motor Which Capacitor Required? | कौन सी एचपी मोटर किस कैपेसिटर की आवश्यकता है
ฝัง
- เผยแพร่เมื่อ 2 ต.ค. 2024
- Get the BEST Price at Indiamart:
Capacitor : dir.indiamart....
Fan Capacitor : dir.indiamart....
Power Capacitors : dir.indiamart....
This is the most demanded video and most requested video from many of my viewers.. The confusion to select proper capacitor for particular motor is solve in this video. in this video we have shown the calculation to select proper capacitor value for required HP motor.. for details watch this video.. more videos are also available for details do click following link.. / @niketshahplus
#Electrical #motor #capacitor #selection #Technic
Share, Support, Subscribe!!!
Main TH-cam channel : / niketshahpluspoint
Click for membership : / @niketshahplus
Online Courses Android App: play.google.co...
Telegram : t.me/niketshah...
Twitter: / niketshahplus
Facebook: / pluspointtraining
Facebook Myself: / niketshahkalyan
Instagram: / pluspointtraining
For Online Courses Website: www.pluspointo...
Email: niketshah.pluspoint@gmail.com
WhatsApp: +91 9867666073
Online Courses also Available For more details Just call us on : 9768871110..
About : Niket Shah Plus is a TH-cam Channel, where you will find technological videos in Hindi, Technology video on Electronics, Electrical, Computer Hardware Training, Laptop Repairing, Mobile Repairing, Circuit making, Computer Engineering Software Courses like AutoCAD, Animation, Video & Sound Editing, 3D animation, Microsoft Courses, Accounting Software and Many More.. Etc.. All In Hindi... Thankx.. :) - วิทยาศาสตร์และเทคโนโลยี
Get the BEST Price at Indiamart:
Capacitor : dir.indiamart.com/impcat/capacitor.html?YT19&YTI
Fan Capacitor : dir.indiamart.com/impcat/fan-capacitor.html?YT19_1&YTI
Power Capacitors : dir.indiamart.com/impcat/power-capacitors.html?YT19_2&YTI
App ka solution step by step hai to samajhne main koi dhikkat nehi hona chahiye ,thank you eyse video banane ke liye
7.5 एचपी मोटर को 2फेस में चलने के लिए कितना का kipicitar लगाए
Very useful information sir, thank you very much......
Bahut achhe bhai
Single phase submersible pump (angle company) 15A-500v How many uf rated capacitor should i use.🙏
We don't want your like just answer the questio 🤨
Mera pas ek makita company ka lawn power machine aya 1600 watt (2.2 hp) isme kitna mfd capacitor use karuji ?pls boliye......
Koi reply nahi
सर सिंगल फेस 1 hp मोटर में normly 8 से 10 uf का कैपेसिटर लगता है।
आपकी calculation के हिसाब से तो बहुत ज्यादा वैल्यू हो जायेगी
आपने बहुत ही अच्छी जानकारी दिए लेकिन सर रनिंग के बारे में भी ऐसा ही वीडियो बनाओ और रनिंग और स्टार्टिंग दोनों के बारे में बताओ
0.5hp moter me 20mfd capacitor lagega?
Well don boss
Very good
Ye running capictor formula h. STARTING CAPICTOR KA KAISE NIKALE.
2 hp 2900 rpm single phase induction motor me kitna ka capacitor lagega ,? Pl iska calculation bataiyye
Sir kitne hp ki motor kitne time me kitna current legi ispe bhi video bany
will try send me whatsapp on +919768871110
Awesome
Sir Lubi 2hp motor ka which capaciter dalan bai bolo jara
Thank you so much sir ji
Sir jis submersibal me 3capacitor ya 2 capacitor lagte h une kese select kre uska formula kya hoga please reply
Par hp 30 MFD agr aapki 5 hp ki submersible moter he to 150 MFD jese 50 MFD ke 3 kipictors
Mey ak kisan hu or ape ney mere bhoat kam ki chej samjai hey thanks brother
भैया मुझे 7.5hp की मोटर मे कितने का कैपेसिटर लगेगा
Stabilizer se changer cut video banaye
What is the difference between MFD capacitor and uf capacitor?
same
Your lessons are easy to understand. I am learning so much from you. thank you.
What about DC if the motor 7.5Kw with 72v ?
Double phase ke liye yahi formula use hoga??
sir what is the value of 1000 in this formula
how can I calculate winding coil size depending on power?
Pre hp 30 mfd me use krta hu abhi tk kuch problem nahi aaya?? Submersible moter
Sir how we calculate the starting capacitor calculation formula of any motor and running capacitor calculation formula of any motor plz tell me before I was also asking with you but not give any replay of my question
বৌ ভ্যানের মটরের কাজ করেন ভাই
1hp sumbersible pump ke capacitor kharap hai kaise malu chalega. Capacitor ko kaise chek kore.
Bahut Achcha question
Nice video
5hp single fez me kitne ka capacitor laga sakte hai.
Ata chakki me kitana MFD k capisitor lagega ji
Sir capacitor or Controler same chish hai?
Sir what about running capacitor
Five manjil overhead water pump no nameplate capiciter damage how changed
ratting capisiter please give me answer
Bhai motar ka hp kse nikale kse pata chale ga motor kitne hp ki hai
Capacity run aur capacitor rating me fark hai kya....humare ghar par Crompton aquagold 1hp motor hai aur uska capacitor jal gaya hai...uska rating nhi dikh raha but motor pe capacity run likha hai 15 microfarad....isliye pucha plz help...Mai 25 Ka lu ya 15 ka???
kya shi ha bhai 1 hp ke pump me to 10 mfd ka lga hota ha ,please explain
Thanks sir aap ka samjhhane ka tarikka supper Nice hai
Bhai mere machine ki motor capastor jala rahi hai main ne uska cloch b change Kia lakin koi hal NAI ho raha
Sir mere pas 1.1hp motor hai usme 10 uf ka capacitor laga hua h
dude what's with the two languages... pick one and stick with it then make a different video.. what a nasty sounding language
Capacitor induction motor me speed control ke liye kone sa dimmer lagaya jayega singal phase half hp 220v motor please send me details
Koi reply nahin aati to question ka Sahi answer Kaise janenge Sabhi log FIR kya matlab Hua jabki Kaha gaya hai koi bhi question ho to aap mujhe likh de
Sir running capacitor ka kya formula ho ga
Thanks sir
सर् जी मेरे पास कार वास मशीन है उस मशीन मे 2hp सिंगल पेश मोटर लगा है5मिनट चलने पर बहुत ज्यादा गर्म हो रहा है कृपया गर्म न होने का उपाय बताये
9166373037
Very useful information sir
Bahi abhishek us motor me 12 ka capacitor use kro
Sir sorry to say, Jo aap bta rhy hain ye running capacitor formula h
Very Good Sir Gujarat
Sir 1hp ke anusar
watt 746/2=373 rakhne par capacitor value galat batata hai. Please sir 0.5 hp motor capacitor calculate video bhi upload kijie.
मुझे भी बताओ
I have not understand capacitor selection either running or starting capacitor
Very nice Guru ji
Sir running ke liye video banaea
Sir transformer ki full winding video update karo
But 0.5/0.25/0.75/1.5etc is moter ka capacitor kase nikale..
1.50 hp motor hi Jo 2 fes chalti hi night me nhi single fes chalti hi kitne ka kandenser lagega
Don't do that it will damage your motor
Induction moter start ma double load lati hai jasay k half ho 380 but start ma 746 watt kia as say farq ni paray ga
Calculation of motor winding and its wire gause !
Cd135A 400v3300uf 85c positive kaha उपयोग करे ओर किया जाता है.
Hi sir for sub mersible pump how to select start and run capacitors
Sir aapki square wave inverter circuit vali video Mai kite volt ka capacitor lagega please reply me
Texmo 1hp jet pump
25.sal Purana Hai
Kaunsa Capicitor lagega
Tell me please sir starting capacitor formula
10 HP boring motor ke liye capacitor banaaiye
Second price vary high agar ham koi b naye t shirt ta or koi product par khud apna manchaha logo print karvaye to jo apne price Rakhi h use 60 se 80 parcent Kam price me print ho jaye
सर् एक सलाह चाहिए, मुझे एक 10 hp की मोटर पर 24 इंच हॉरिजॉन्टल आटा चक्की लगानी है तो कितने kw का थ्री फेस कनेक्शन लूँ।
आपकी सलाह की बहुत जररूत है, धन्यबाद
Mere paas ek single phrase 3hp motor hai aaur iska starting capacitor baar baar fuk ja raha hai kya problem hai please reply
Incomplete information.
Sath me dukhana tha motor me ki kitna ka use kar rahe, kitne range tak liya ja sakta gai etc.
Fir example yahan 25 mfd aaya, to iska kya matlab? 25 se kam lenge, ya 25-35 lemge ya kya lenge?
Aapne capacitor start aur capacitor run motors ke baare mein pucha tha, aur ab aap specific capacitor values ke use ke baare mein jaan-na chahte hain. Main isko thoda detail mein samjhata hoon.
Capacitor Start Aur Capacitor Run Motor Kya Hote Hain?
Capacitor Start Motor:
Is motor mein ek start capacitor use hota hai jo motor ko start karne ke liye zyada torque provide karta hai. Start hone ke baad, yeh capacitor motor circuit se disconnect ho jata hai.
Start capacitor ki value typically 70 mfd (microfarad) se lekar 200 mfd tak ho sakti hai, depending on the motor's power rating.
Capacitor Run Motor:
Is motor mein ek run capacitor hota hai jo motor ke running state mein bhi circuit mein rehta hai, isse motor ki efficiency aur power factor better hoti hai.
Run capacitor ki value typically 2 mfd se lekar 50 mfd tak ho sakti hai, depending on the motor's design aur requirements.
Capacitor Value Selection:
25 mfd ka Matlab Kya Hai?
Agar aapko ek motor ke liye 25 mfd capacitor recommend kiya gaya hai, to iska matlab hai ki aapko 25 microfarad ka capacitor lagana chahiye.
Ye value motor ki design aur uski specifications par depend karti hai, jo manufacturer ne decide kiya hota hai.
Value Selection Tips:
Lower Value (e.g., 20 mfd): Agar aap recommended value se kam capacitor use karte hain, to motor ko sufficient torque ya power nahi milega, aur motor overheat ya underperform kar sakti hai.
Higher Value (e.g., 30 mfd): Agar aap recommended value se zyada capacitor use karte hain, to motor ki efficiency kharab ho sakti hai, aur motor overheat hone ka risk badh sakta hai.
Recommended Range:
Agar aapko exact value nahi mil rahi hai, to aap thoda adjust kar sakte hain. Jaise agar 25 mfd required hai, to aap 23 mfd se lekar 27 mfd tak use kar sakte hain. Lekin, recommended value ke aas-paas hi rehna chahiye.
Example:
25 mfd Capacitor: Agar aapke motor ke liye 25 mfd capacitor recommend kiya gaya hai, to ideally aapko 25 mfd ka hi capacitor use karna chahiye. Agar yeh value nahi mil rahi hai, to aap 24-26 mfd ke range mein capacitor try kar sakte hain, lekin 25 mfd ke kareeb rehna zaroori hai.
@@NiketShahPlus thanku so much bro, itna detailed me samjhane ke liye, mere Crompton pump me 20 mfd ka specification me likha hai plate me, jabki Mera purana Jo laga hua tha vah 25 mfd tha, Maine 25 ka abhi abhi kharida.kal Morning me fit karunga, ab aap batao 20 sahi rahta ya 25.
Ab mujhe yaad nahi mera old wala original yani pump ke sath diya tha ya baad me laga hai, Lekin purana kaafi hoga, Geofarad company ka tha.
Abhi indtech ka laya hai 90 rupye me hi mil gaya.
3 HP मोटर सिंगल फेस आट्टा चक्की हे रनिंग न कापीसीटर कैनसा लगाएं पिलीज बताऐ
50 एमएमटी कंडेनसर लगाओ
Why 1000 use
Nice video sir thanks
Ye engineering logo k t shirt h usme civil/IT/Electrical engineering logo k product h kya
Soon
1000 why
1000
Mere pass old motor hai usme level nahi hai to kaise pata kare ki motor kitne hp ka hai aur capacitor kon sa lagaye
Thank you Sir for reminding me my eng. College days 👌👍👍👍🙏
1440 Rpm 2 hp motar ke kitne mfd candensar lagega
Staring & running ko
Will try to make video on it
सर मेंरी 1.5 HP की टुल्लू है। टुल्लू के लगातार चलने पर उसका केपिस्टर फट गया था, उसमे 25 mfd का केपिस्टर लगा था लेकिन मेने 25 uf का कैपेसिटर लगा दिया। सर तब से मेरा टुल्लू सही से पानी नही खिंच रहा। सर आपके हिसाब से कैपेसिटर की प्रॉब्लम है या टुल्लू ही खराब है???
2 hp & 2 phase. Monoblock motor kitne amp legi & kitne mfd ka capister lagega
Bhi wo 2phase motor (3.25 amp) la gi and (206mfd) hu ga ......
Jisne motor ko banaya h.. Vo kahta
h ki 6-7 amp legi
Aisa kyu h Bhai
Reply me
@@s.pyadav3688 Bhi jan ma na written calculate kr ka btatya ha oar apko jis na 6-7 amp btaya ha wo idea sa btaya hu ga but ma na asy ni kia ma na written calculate kr ka apko btaya ha
Sir I bought a new .5hp swj pump but this nameplate capacitor value is 20 mfd how?
5 हॉर्स पावर की मोटर में पंखी कैसे लगाएंगे इसके बारे में भाई साहब थोड़ासा आप लोगों हम लोगों दीखाइये पीना की पंखी कैसे फीट की जाती है
आधा एच पी यानी टिल्लूपंप की मोटर मे कितने एम एफ डी का कैपीसिटर लगता है, और ज्दाया एम एफ डी का कैपीसिटर लगाया जाए तो आर पी एम ज्यादा होंगे या नहीं 🤔
Are sir watt/31 se bhi condensar ki welyu mil jayegi
Sir washing machine ki 120 watt ki motor h to kitne uf ka capacitor lagega is calculation se 3.33 nikalta hai but company 8.5 uf ka recommend krti h aisa q
Sir, starting ke jogoh running capacitor loga diya, tob kiya dikkot hoga?
Use stating ka tork nahi milega vh jal jayegi or ho skta he ki aapka capacitors fat jayega
Please input sockets ka kitna resistance Hona chahiye please urgently advise me
Mitti.ka.chak.banane.me.kitanr.hp.ka.hogga.sir
Thanks sir from Bangladesh, I have 2 HP water pump.... How many uF Capacitor requard ??? If i use 35uf or 31uf problem it ???
Agar capacitor faraday value kam se karke aur 220 v ke alava 440v laga tho,kya hoga...
Sir 1.5 HP ke motor me kitana MFD ka run capacitor lagega aur aur 3phase motor hai bina clach plet ka to Singal phase winding Kar sakate hain kya aur Kar sakate hain to running & starting wire number kya hoga aur runing & starting wire wiat kitana hoga jawab den sir please..
Mera cooler bnd ho gya....6mm ka capacitor market m available nh h.... to m kitne mm ka capacitor lgau...4mm ka lgaya h cooler chal gya h... but mjhe 6 mm ka bnane k liye kya krna chahiye....
35 uf capastor kon si motor ko lagaya jata he ?
Very helpful video for all technician and electrician
10 hp kitna legga 3 phess hai usko single pe chelana hai
बहुत अच्छी जानकारीदिए आपनेथैंक्स
Power factor ke sath calculation karo ji
Kya 10uf 440 VAT ka capiceter कूलर में लगा सकते है
Bhai simple bhasa me batao 1hp me konsa lagega