Cleaning all in one outside unit evaporator and condenser coil - Package Unit Air conditioner AC

แชร์
ฝัง

ความคิดเห็น • 28

  • @420Giancarlo
    @420Giancarlo 2 ปีที่แล้ว +8

    *So amazingly quiet and **Fastly.Cool** in my room! 42db is at a whisper level. I bought 2 and installed myself.Very sturdy bracket and easy to adjust to fit windows of different size. Absolutely fabulous units!!*

  • @NGAR239
    @NGAR239 11 ปีที่แล้ว +3

    Wow! That's a 2004? That's about the cleanest 2004 system I have seen in a long time.

    • @michaelmace924
      @michaelmace924 5 ปีที่แล้ว

      It looks even better 5 yrs later, 🤣🤣🤣

  • @GachanB
    @GachanB 11 ปีที่แล้ว +2

    i always wonder why those outdoor AC look so huge. now i see how much is packed into one unit.

  • @DIYTinker
    @DIYTinker  11 ปีที่แล้ว

    bought it at locke supply, but you can find it on Amazon as well.

  • @RyanMattockpyro
    @RyanMattockpyro 8 ปีที่แล้ว

    thanks for info!

  • @dillonle4034
    @dillonle4034 5 ปีที่แล้ว

    How do you clean if the furnace locate inside home?

  • @theelite5353
    @theelite5353 2 ปีที่แล้ว

    I am currently trying to create a bid for a customer how long does this process usually take with 2 techs, Also I want to add amp draws to the bid, comp,blower,cap,cond fan motor??

  • @Eddy63
    @Eddy63 7 ปีที่แล้ว +14

    Are those OSHA approved safety flip-flops ? lol

  • @ball-se6gu
    @ball-se6gu 5 ปีที่แล้ว

    Hey man... hoping for a reply here. I'm a carrier transicold tech in upstate ny. My parents home has a Miller all in one outside unit. Past 4 years it's been freezing hellaciaously in hot weather. Blower spins well, all fins intact. Condenser fan operates well, condenser is clean. Could poor evaporator return placement be the cause? It's a double wide modular home, the return duct and filter is on the lowest floor. I was thinking low charge, causing poor superheat after the expansion valve. This thing is a bitch to get the covers off, years ago before becoming a carrier tech the unit was looked at and the "hvac" tech had no fix. Now that I'm a dealership trained carrier tech, I feel like I have the ability to deal with this, but being a complete unit, there seems to be a lot more variables involved in an all outside unit, strapped with it's own blower, with the evap coil outside. Even poor sealing in the evap box allowing hot, moist air into the coil, ruining its ability to cool the house cause of freezing moisture. Lmk what you may think

    • @actechformallyyomama746
      @actechformallyyomama746 4 ปีที่แล้ว +1

      8ball4554 it’s possible that it is a low charge or an airflow problem. Get me the model # of the package unit and filter size. If possible the duct size going to and coming from the unit. If you have gauges get me the pressures.

  • @YoDIYVideos
    @YoDIYVideos 11 ปีที่แล้ว

    Tell me where you bought this cleaning solution.

    • @michaelmace924
      @michaelmace924 5 ปีที่แล้ว

      You get the best stuff from an HVAC supply house.

  • @palmtrees9544
    @palmtrees9544 3 ปีที่แล้ว +1

    Won’t the drain pan get clogged with gunk and start over flowing?

    • @MAGAMANPATRIOT
      @MAGAMANPATRIOT 2 ปีที่แล้ว

      You'd need to clean the pan and check to make sure they're open last. If you have tubing directing away from unit make sure it's open too.

  • @purpledancer4914
    @purpledancer4914 4 ปีที่แล้ว

    Does this stop the dirty sock syndrome?

  • @The70slady
    @The70slady 8 ปีที่แล้ว +1

    the how to did not show enough and was not explicite about the two sets of coil, any difference in doing the cleanup and where they are.

  • @TimeFlyingBy1884
    @TimeFlyingBy1884 3 ปีที่แล้ว

    What is the towel for at 2:40? Thank you.

  • @lukehailey4833
    @lukehailey4833 2 ปีที่แล้ว

    How long did this take from start to finish? I'm looking to do this for the first time in the next couple days.

  • @S0berSpirit
    @S0berSpirit 8 หลายเดือนก่อน

    Where is the filter for these all in one units located?

  • @MrDaveGeneric
    @MrDaveGeneric 10 ปีที่แล้ว

    What are those leggings? Compression "socks"?

    • @stephenburkhart8052
      @stephenburkhart8052 7 ปีที่แล้ว

      yeah, wondering about them myself. Sort of in a good way. What brand are they? Do they help? Thanks!

  • @The70slady
    @The70slady 8 ปีที่แล้ว

    the how to did not show enough and was not explicite about the two sets of coil, any difference in doing the cleanup and where they are. oh, I see. if comment is negative you refuse to report how improvements to video could happen. I've got it.

    • @actechformallyyomama746
      @actechformallyyomama746 4 ปีที่แล้ว

      Ellayn Chadwick both coils on this unit are tube and fin. If either coil is a micro coil or spine coil water only should be used. I apply cleaner to the evaporator coil with the drain on and remove it to rinse the coil. This allows for better drainage while rinsing. The cleaner that went through the drain line helps break down the debris in the drain line and is easier to flush out. I’m not sure why they had the white towel in the unit. Hope this was helpful.

  • @The70slady
    @The70slady 8 ปีที่แล้ว

    the how to did not show enough and was not explicite about the two sets of coil, any difference in doing the cleanup and where they are.