How to Install Low Profile Underfloor Heating ~ ProWarm LoFlo

แชร์
ฝัง
  • เผยแพร่เมื่อ 29 ธ.ค. 2024

ความคิดเห็น • 180

  • @bordersw1239
    @bordersw1239 10 หลายเดือนก่อน +34

    Very good, now please do one on thermostats so even my wife can understand the bloody things!

    • @RI-uv3lm
      @RI-uv3lm 10 หลายเดือนก่อน +2

      😀

    • @normanboyes4983
      @normanboyes4983 10 หลายเดือนก่อน +16

      Just give her own thermostat but do not connect it to anything. Job done.

  • @UrbanPlumbers
    @UrbanPlumbers 10 หลายเดือนก่อน +32

    Roger, nice to meet you the other day. We need to have a talk about the UFH design, manifolds, and pumping and mixing on them. The way you did this in the video is a high-temperature setup - this is not the way UFH should be done in the 21st century. I would love to explain the modern way of doing those systems to you.

    • @SkillBuilder
      @SkillBuilder  10 หลายเดือนก่อน +23

      Hi Simon
      I understand the concept of leaving out the mixing valve and circulation pump but this house has six bedrooms with radiators and a dining room and music room that will never be changed to low temperature. Like it or not, the customer's wishes must be respected. I am concerened that you and the other Heat Geeks are putting the environmental issues before the customer's best interests. It will erode trust and undermine your good work.

    • @UrbanPlumbers
      @UrbanPlumbers 10 หลายเดือนก่อน +14

      @@SkillBuilderRoger - running UFH in this manner is less efficient on fuel and less comfortable for the customer. You need 40C to that UFH at -2 but not at +10. There is also no need to send 60-70C to the manifold just to be blended down to 40C again.
      Please, let me take you on some of my projects and show you the modern way of installing UFH - everyone wins here - the client has lower bills and higher comfort, the boiler cycles less, and has much less wear and tear. I am talking about WC and electronic blending valves here.

    • @SkillBuilder
      @SkillBuilder  10 หลายเดือนก่อน +14

      I heard all that but you didn't answer my point about the rest of the house needing a flow temperature of 60 deg. The mixing valve works to solve this.

    • @egocd
      @egocd 10 หลายเดือนก่อน +6

      ​@@SkillBuilderDoes the rest of the house actually need 60 deg, though? Have they tried turning the boiler down to 45/50 deg on a cold day to see if the house is still heated effectively? Does it have weather compensation? Personally, I can run my boiler flow at 45c and the house still gets warm on a cold day. Unfortunately I do not have a combi boiler, so have to keep the flow at 60c due to the DHW requirement. I didn't see in the video what type of boiler this customer had, but even without changing anything in the system, lowering the flow temp would save them a good amount of money. Weather compensation would save even more, if the boiler supports it.

    • @paullongley1221
      @paullongley1221 10 หลายเดือนก่อน +1

      Hi, I’m not meaning to ‘muddy the waters’ but would it be possible to run the UFH from the radiator return line ??
      I realise it limits the UFH to only running when the radiators are on, unless it has a secondary direct feed, and the complications etc.
      Just putting the thought out there.

  • @mozzer999
    @mozzer999 10 หลายเดือนก่อน +6

    Very comprehensive, each aspect really well explained, feel I could have a go now. Cheers Roger

  • @billycan8852
    @billycan8852 วันที่ผ่านมา +1

    works great with air source heat pumps

  • @copperskills3973
    @copperskills3973 10 หลายเดือนก่อน +3

    The issue that always comes up is the flow rate difference between the radiator circuit at dt20 and the underfloor heating of dt11. Unless a hydronic separation is used then the ufh will pull the water from the radiator circuit and boiler to achieve its design flow rate and both will suffer. I get many, many calls to this with rooms suffering heat losses as the flow to the rads being cut short.

  • @mindaugasvaskevicius1818
    @mindaugasvaskevicius1818 10 หลายเดือนก่อน

    I needed this video 2 months ago. Couple of pointers that would have been really useful. 90 degree blenders at the collector... I'm still gonna do that. People usually criticize me for using multilayer pipe(PEX/Al/PEX) they said I should have used PEX, because it transfers heat better, but I prefer my oxygen isolation to be layer of aluminum rather then sprayed on stuff that is afraid of light and you can scratch it if you are walking on it or mounting it on metal mesh. I'll rather trust a person who does things rather than some podcaster who does lots of simulations and theoretical visualizations. My wife is definitely is a person who doesn't understand thermostats 🤣

  • @al-azimahmed1188
    @al-azimahmed1188 10 หลายเดือนก่อน +2

    Good old Roger, perfectly explained. Roger do have any idea what the concreter floor build up was ?
    I have about 4.5 inches of concrete and the just backfill ruble ( 50's house, i only know this because i had to dig up the floor to get a new mains in).
    I was just worried about the floor absorbing the heat ?

    • @SkillBuilder
      @SkillBuilder  10 หลายเดือนก่อน +2

      With no insulation you are always going to lose heat. This was concrete on rubble. It should have been dug up but there is a limit to what people want to spend.

  • @Unknown_Tranquility
    @Unknown_Tranquility 8 หลายเดือนก่อน

    Really good video, especially with the focus on EPC ratings and the desire for households to install these systems.

  • @yngndrw.
    @yngndrw. 10 หลายเดือนก่อน +3

    Informative as ever Roger, always a pleasure to watch your videos.
    You've misused the wire ferrules though, as you crimped the plastic instead of the metal - You're only meant to crimp the metal. In a screw terminal, it probably wouldn't matter as the screw will do the crimping for you, but in a Wago connector as you've used them it isn't likely to crush the metal of the ferrule. I think these connections will have a high resistance and are a fire risk if you don't go back and re-crimp them.

    • @SkillBuilder
      @SkillBuilder  10 หลายเดือนก่อน

      I will look into that but crimping the metal allows the conductor to pully out. I will check it out and add a comment. Have you a link to a video or instructions?

    • @yngndrw.
      @yngndrw. 10 หลายเดือนก่อน +1

      @@SkillBuilder it could be that the ferrule is too big for the wire or it could be the crimper - I did notice the same with that type of crimper, I ended up switching to a Knipex crimper which is pricy but very reliable. The efixx channel has a few videos on ferrules so I'd suggest checking them out, you'll see from their videos how tight the crimper should be doing them especially the ones with the square dies.

    • @nobodydoesithalfasgoodasyou
      @nobodydoesithalfasgoodasyou 10 หลายเดือนก่อน

      I am not familiar with these connectors but I happened to see James from Plumber Parts using them in a video (th-cam.com/video/5od-dowQKY0/w-d-xo.html ) and he certainly crimped the metal. @SkillBuilder Edited because TH-cam garbled my link and then my comment

  • @TineBeo
    @TineBeo 4 หลายเดือนก่อน

    What a resource you are Roger. Love from Ireland.

  • @Exposure2life
    @Exposure2life 10 หลายเดือนก่อน +1

    Tidy job and well explained, something I would aspire to have done at home on the ground floor.

  • @reganovich
    @reganovich 9 หลายเดือนก่อน

    excellent Roger..back to great content!

  • @RI-uv3lm
    @RI-uv3lm 10 หลายเดือนก่อน +4

    Fantastic video, Roger! Suggest you do a full step by step series on this;
    - desired temperatures
    - managing humidity
    - thermostats & types
    - pipes & types
    - run lengths
    - manifolds
    - pumps
    - solenoid valves
    - electrical connections & automation
    - water supply & of course,
    - common mistakes &
    - problems faced by users
    - how to fix them
    - There is no video or series on the internet/TH-cam giving comprehensive information
    - This will be as popular as your bathroom build series

    • @JamCamel
      @JamCamel 10 หลายเดือนก่อน +2

      This would be brilliant.

  • @guygillmore2970
    @guygillmore2970 10 หลายเดือนก่อน +2

    It would be great if you could give a talk about insulation under UFH for retrofits. We know what building regs are but if you absolutely can't rip up the floor, what can you get away with? They always say the first inch of insulation is the most important and if the area is large and square the perimeter losses will be small. Perhaps another collaboration with Heat Geek?

    • @SkillBuilder
      @SkillBuilder  10 หลายเดือนก่อน +6

      We have a follow up on this video where I talk about those issues. It was just too long with that bit in but we will put it out next week.

  • @raducristiandumitrescu1806
    @raducristiandumitrescu1806 10 หลายเดือนก่อน +2

    Compared with a similar system like gas central heater and radiators, how much power consumes to do the job at the same room temperature ?

  • @aaronharris5275
    @aaronharris5275 10 หลายเดือนก่อน +1

    Sorry what were the black floor pieces where you showed the light bulb lay pattern? Can you over the whole floor with tile adhesive or do you need that matting ditra matt? Wunda are another company to consider.

  • @aurelijusap
    @aurelijusap 10 หลายเดือนก่อน +1

    If you have a wood fired boiler without additional accumulative hot water storage can you still use radiators on one floor and underfloor Heating on the other and just rely on mixing valve to have lower temperature than radiators?(if lets say heater produces ~60c temp. hot water)

  • @firasm.younis8939
    @firasm.younis8939 3 หลายเดือนก่อน

    Thanks for this valuable information, please can you show the correct way for soldering the copper pipe with my regards

  • @willh5061
    @willh5061 4 หลายเดือนก่อน +1

    Good morning. It would be great in these videos if you could give a ballpark total cost of everything. I know prices change over time but if you also state the year of recording that would fix that. Many thanks.

  • @markatchison9974
    @markatchison9974 10 หลายเดือนก่อน +4

    The heat from the pipes will leak into the walls & through those bifold doors to the outside.
    I know this from my own system, & the simple test is to watch how quickly your patio dries near the doors after it's rained.
    Make sure there's some kind of insulation under the door sill & around outside walls. Otherwise you'll lose a percentage of your heat to the outside.

    • @benwatton1832
      @benwatton1832 10 หลายเดือนก่อน

      This is called heat loss get it in every building with whatever heating system it has?

    • @markatchison9974
      @markatchison9974 10 หลายเดือนก่อน +2

      @@benwatton1832 I'm explaining how to limit heat loss in underfloor systems particularly.

  • @PercyJackson93
    @PercyJackson93 6 หลายเดือนก่อน

    Great video! I love the idea of a plastic piping. Is it a good idea to use on installing a hot water tank as well? I am installing a boiler wood stove and thermal store. I would do the expansion tank lines in copper just encase as this could overheat but does anyone have experience with the rest of the system?

  • @TheLife0025
    @TheLife0025 หลายเดือนก่อน

    @15:18 Flow value is 0.70 L/min for 70.5m pipe . Isn't it calculated by length of pipe divided by 40? so Flow should be 70.5/ 40 = 1.76 L/min

  • @johnrosenfeld
    @johnrosenfeld 10 หลายเดือนก่อน

    Interesting video Roger and quite timely as I'm in the middle of a similar UFH job. Just one issue. The pipe configuration you are using means that the section of the room that receives the flow pipe first will warm up faster than the section of the room closer to the return leg. This will probably lead to unequal warming of the room and dependent as to where you place your room thermostat may lead to control issues. There is a better way of configuring the pipe so that a warm flow section of pipe is always laid parallel to a cool return section of pipe thereby evening up the floor temperature. I would include a diagram to illustrate my point but can't see how to do this in the comments section. Also the lack of proper insulation below the ufh pipes would concern me. Apart from that great job!

    • @SkillBuilder
      @SkillBuilder  10 หลายเดือนก่อน +2

      The drawings for the pipe runs are provided. I would like to see your idea. I use a snail pattern in castelated trays because that does what you describe.
      The lack of insulation under the panels is a problem and I would probably have hacked the floor up and got some insulation in there and then pumped a screed over the lot but that is a lot more involved and expensive.
      If you earn your living at this game you have to bend to the customer's will every now and then.

  • @ciaranclose192
    @ciaranclose192 10 หลายเดือนก่อน +2

    Did you fit this to an existing floor without lowering it and if so what additional height has been added in total to the finished floor including covering?

    • @davidscott3292
      @davidscott3292 10 หลายเดือนก่อน +1

      And presumably there is a step up into the part of the house that has had this system installed.

  • @ZippedAuto
    @ZippedAuto 10 หลายเดือนก่อน

    Great video as always. Could you put those isolation valves on the flow and return pipes going to the underfloor heating manifold instead? Would make changing the pump easier in the future if need be.

  • @RichardTurley-x7c
    @RichardTurley-x7c 6 หลายเดือนก่อน

    Hi! Could you tell me if karndean/Amtico floor covering will go directly on top or would you need another layer of self levelling first? If so, how thick? Cheers!

  • @russellsmith6476
    @russellsmith6476 10 หลายเดือนก่อน

    Did the myson version about 5 years ago 189m2
    Tip to line boards up use 2 bits of off cut stop them moving around when glueing and screwing

    • @SkillBuilder
      @SkillBuilder  10 หลายเดือนก่อน

      Yes I also do that with the pipes

  • @sdlsdl9000
    @sdlsdl9000 2 หลายเดือนก่อน

    Hi
    Should I fit a bypass value on my logic plus boiler when converting to heating and UFH
    Thanks Steve

  • @Tom-Lahaye
    @Tom-Lahaye 10 หลายเดือนก่อน

    Well explained. But when I run the system with a heat pump on low temperature, say max 40°C delivery from the heat pump, I will not need the mixing valve and circulation pump on the UFH manifold?

    • @SkillBuilder
      @SkillBuilder  10 หลายเดือนก่อน

      You don't have to use it but very few systems are set up for heat pumps. This house has radiators and solid walls. It is 200 years old and a listed building so it can't even have double glazing.

  • @RR-mt2wp
    @RR-mt2wp 10 หลายเดือนก่อน +2

    Great video, Roger.

    • @SkillBuilder
      @SkillBuilder  10 หลายเดือนก่อน

      Many thanks

  • @cdh601
    @cdh601 10 หลายเดือนก่อน

    Good video Roger, jusr wondering if connected to a combi with radiators i take it an S plan would be needed?

  • @petehiggins33
    @petehiggins33 10 หลายเดือนก่อน +1

    Is there any possibility of putting insulation between the concrete spreaders and an existing 1960's concrete slab or do building regs prevent this due to height restrictions?

  • @PaulDino02
    @PaulDino02 9 หลายเดือนก่อน

    Can you mount the cement board on top of an insulation medium? (Cellotex or even Elements tile backer)? I'm paranoid about putting heat into the floor below. I am proposing to break the cement screed up on top of a block and beam floor. in view of maybe installing a hybrid air source heat pump. Thanks P

    • @PaulDino02
      @PaulDino02 9 หลายเดือนก่อน

      Any thoughts? Keen to know what you think?! 👍

  • @farmind6582
    @farmind6582 3 หลายเดือนก่อน

    Help, I have a 70 mm max space between the OSB floor and the bottom of the door frame, I need to put another layer of OSB on top of 25mm to strengthen the floor, the top finish floor I need 15mm that leaves me 50cm in the middle is that enough space? Can I lay this system direct onto OSB with a insulation layer? Thanks

  • @TooMuchInfoSir
    @TooMuchInfoSir 10 หลายเดือนก่อน +3

    Hey Roger, i bought a load of 15mm Hep2o pipe at £200 for 100m, but then i decided to go UFH i got the 100m for £75 for 16mm. Looking at the stats, the UFH pipe is superior. Is this a con? Why arnt we using Pex for dhw / water?

    • @sigi9669
      @sigi9669 9 หลายเดือนก่อน

      While there certainly are PEX pipes for drinking water, please don't go and use one rated for UFH for this!
      All plastic pipes leak some chemicals into the water, but the ones rated for potable water have a limit at least.
      Having said that, there are indications that even "food safe" PEX degrades quicker than expected. Leading to unsafe levels of chemical leaching within the projected lifetime of the system.

    • @TooMuchInfoSir
      @TooMuchInfoSir 9 หลายเดือนก่อน

      @@sigi9669 Thanks for the reply! I wont, I have the Hep2o anyway lol - but interesting about the chemicals. I assume the increased cost is related to the tougher standards, testing and grade of plastic then. Cheers!

  • @25binny
    @25binny 9 หลายเดือนก่อน

    Hi Roger, really nice video! just a relevant question, you didn't seem to be laying any insulation material underneath the screed boards (unless I missed it). My question is do you have to? I have a company offering underfloor heating system by putting grooves into the concrete floor. I'm sceptical about the efficiency of such system without any insulation material. Although, as its a new house, there must be some sort of insulation gone in the concrete floor (sandwiched b/w two layers).

    • @SkillBuilder
      @SkillBuilder  9 หลายเดือนก่อน

      If you have insulation under the slab it will act as a thermal store. Sadly this house doesn't have that insulation so the bills will be higher. How much higher is hard to say but it is not an ideal scenario.

  • @stevenyates6732
    @stevenyates6732 9 หลายเดือนก่อน

    The vidio was good, but left me wondering about insulation, in modern floor there should be insulation already, but in old concrete floor there maybe little or none? Will heat be absorbed by floor?

    • @SkillBuilder
      @SkillBuilder  9 หลายเดือนก่อน

      Yes you will lose heat for sure

  • @hrvojelasic5794
    @hrvojelasic5794 10 หลายเดือนก่อน

    Nice to see you working :)

    • @SkillBuilder
      @SkillBuilder  10 หลายเดือนก่อน +4

      I try the biggest problem is that I can't always film myself and do the job. Even setting up a camera on a tripod slows me down when I am trying to get the job done. Also customers get a bit agitated if they are paying me and I spend half the day monkeying around with lights and cameras, not to mention my makeup.

  • @RonanHaughey1
    @RonanHaughey1 10 หลายเดือนก่อน +1

    How do you check the temperature of the flow after the mixing valve? You suggested 40deg? But how is this verified? Great video!

    • @SkillBuilder
      @SkillBuilder  10 หลายเดือนก่อน +1

      The mixing valve has the temperature on it. I just trust it and if it is a bit too hot or cold I adjust it. You can use an infra red thermomter.

    • @tomaszbonkowski1938
      @tomaszbonkowski1938 10 หลายเดือนก่อน

      Roger, this this system with the pump and Hand-adjusted mixing valve in manifold box is for high temp heating source. If you will use HP or condensing boiler on it it could make problems because you cannot use weather adjusted heating curve.

    • @normanboyes4983
      @normanboyes4983 10 หลายเดือนก่อน

      @@tomaszbonkowski1938Well spotted. But it is down to the customer if he had the UF designed properly and specified a lower flow temperature - say 35c at - 2C t hen he could have binned the blender (and maybe the pump) - it would then be future proofed if he ever went heat pump. However he would have also have to review his rad sizes elsewhere and make adjustments where necessary.

  • @MrFlyby34
    @MrFlyby34 10 หลายเดือนก่อน

    Hi thank you and well explained! What kind of screed and thickness was used on top? Cheers

    • @SkillBuilder
      @SkillBuilder  10 หลายเดือนก่อน +1

      The tiles go straight on top.

    • @MrFlyby34
      @MrFlyby34 10 หลายเดือนก่อน

      @@SkillBuilder hi perfect and thanks

  • @gamereva6413
    @gamereva6413 10 หลายเดือนก่อน

    Great vid.
    The flow and return to the manifold. Are they the primarys, or secondary flow and return,?

    • @SkillBuilder
      @SkillBuilder  10 หลายเดือนก่อน

      I do them as separate primaries teed off the heating flow and return

    • @gamereva6413
      @gamereva6413 10 หลายเดือนก่อน

      @@SkillBuilder that's great. Thanks.

  • @NeoAngel91
    @NeoAngel91 10 หลายเดือนก่อน

    Hello @SkillBuilder , thank you for the video, did you use any insulation for the floor or it is not required for this setup? thanks!

    • @SkillBuilder
      @SkillBuilder  10 หลายเดือนก่อน +3

      We have another video following this where I talk about that. It is always best to put as much insulation in a floor as you can but a lot of people can't have anymore build up and if you don't want to hack up the floor you may accept that you are going to lose some heat downwards. After a few days the mass of concrete warms up and it acts as a heat bank.

  • @gibbodive140
    @gibbodive140 10 หลายเดือนก่อน

    Hello Roger. I would be interested to know what percentage of heat is lost through an uninsulated solid floor ? I have spoken with a couple of manufacturers but they become very coy when asked this question ?
    Thank you

    • @SkillBuilder
      @SkillBuilder  10 หลายเดือนก่อน

      Heat travels to cold and the rate at which it does so is determined by the temperature difference. You also need to know the perimeter to do the calculation. If you can get some insulation in then do it. I have this low build in my cellar and it warms up very quickly and has no insulation under it. I keep it on for less time

  • @Banunnaki
    @Banunnaki 8 หลายเดือนก่อน

    bought a house with older floor electrical heating, takes days to heatup, and uses shitloads of electricity a month. at this point just turned it off makes me use triple the amount of electricity.
    Is it because its an old system ?

  • @wrightwells
    @wrightwells 10 หลายเดือนก่อน

    One question you didn’t cover on the commissioning of the manifold, at what point you screed the floor?

    • @mikehealy74
      @mikehealy74 10 หลายเดือนก่อน

      Probably once you're sure the pipes are not leaky!

    • @SkillBuilder
      @SkillBuilder  10 หลายเดือนก่อน +2

      mikehealy
      Yes leave them on test at 3 bar and lay the screed

  • @burwoodbuild
    @burwoodbuild 10 หลายเดือนก่อน

    Very detailed vid Roger and team. 👌🏼😉

    • @SkillBuilder
      @SkillBuilder  10 หลายเดือนก่อน +2

      Thanks 👍

  • @MartialArtUK
    @MartialArtUK 10 หลายเดือนก่อน

    Two questions, 1 does the isolation for the manifold isolate the pump if the pump needs changing? 2 deeper question, seems alot of hassle compared to a wood burner, it's not got any colder these last decades, why do we need our houses to be warmer ?

    • @SkillBuilder
      @SkillBuilder  10 หลายเดือนก่อน +2

      You can change the pump if you power down because the valves on each circuit will close. It helps to release the pressure on the underfloor by taking a little water out of the drain valve.
      As for the question on warmer homes, you can run underfloor heating cooler and still feel warm because the heat is spread more evenly and it is radiated not convected.

    • @MartialArtUK
      @MartialArtUK 10 หลายเดือนก่อน

      Intresting, thanks, another question, that 90 degree plastic angle used to bend the water pipe, will it bend 10mm copper plastic coated?

  • @IAlternateMyCapitals
    @IAlternateMyCapitals 10 หลายเดือนก่อน

    Whats your preferred solution for retrofit? Id like to put a low system on my existing slab through the whole house. The slab has 50mm of polystyrene insulation under the screed. I was hoping to use some sort of foam backed system just to give a little more insulation.

    • @SkillBuilder
      @SkillBuilder  10 หลายเดือนก่อน

      If you have 50mm of insulation under the slab you can use the slab as a thermal store. Yes a foam tray system will do a good job of making more heat travel upwards but if you are putting ceramic tiles on top I would go for the solid cement board. If you are putting luxury vinyl tile on top then you will need a self levelling screed over the trays. If you are putting down carpet some 9mm plywood will be fine.

    • @IAlternateMyCapitals
      @IAlternateMyCapitals 10 หลายเดือนก่อน

      @@SkillBuilder fantastic, thank you! What about for an engineered wood floor? I quite fancy oak parquet.

  • @julianhawker7672
    @julianhawker7672 10 หลายเดือนก่อน

    No CC tee's or low loss header? I would not tie UFH into an existing system without these (unless it was direct into a thermal store)

    • @SkillBuilder
      @SkillBuilder  10 หลายเดือนก่อน +1

      That is your choice. It works well enough. Yes the pumps can work against eachother but we can keep things simple.

  • @icarossavvides2641
    @icarossavvides2641 10 หลายเดือนก่อน

    I'm assuming the floor is insulated?

  • @Aaron-kj8dv
    @Aaron-kj8dv 10 หลายเดือนก่อน +1

    Underfloor heating is so fascinating to me. I'm helping my friend build a pole bar (for those who don't know it's like a giant empty barn where you can do anything. He wants to install hydraulic lifts and work on cars) and I'm going to suggest underfloor heating for it to keep it warm. It's so big and empty that I feel like traditional heating would take forever to heat it up and we're on the Canadian border so we get 4-6 months of snow a year.
    Since I have a very rudimentary understanding, who would help us install this? should we call a plumber or an HVAC guy?

    • @SkillBuilder
      @SkillBuilder  10 หลายเดือนก่อน +4

      You can do most of it yourself. You are right to say that underfloor heating is best for high ceilings.The next video in this series explains why.

    • @liberatodelgreco4430
      @liberatodelgreco4430 10 หลายเดือนก่อน

      Roger, we would like some content from over the pond, maybe you could pop over and give him a hand.
      Awesome video, I’m trying to decide with low profile systems to use, this system is now at No:1, thanks.

  • @mtj2k
    @mtj2k 10 หลายเดือนก่อน

    Great video. Thanks for sharing your knowledge. Have you ever had any experience with the retrofit in slab system such as the JK in-ground system?

    • @SkillBuilder
      @SkillBuilder  10 หลายเดือนก่อน +1

      Not yet! I have heard of it but never seen it done

    • @mtj2k
      @mtj2k 10 หลายเดือนก่อน

      @@SkillBuilder well I’ll let you know. We’re planning on getting it done. Dont want the expense of digging up the old slab and don’t want to lose and height of fitting these types of overlay ones.

  • @John-dp8oh
    @John-dp8oh 10 หลายเดือนก่อน

    Very interesting. It would have been even more interesting if you had included a comprehensive wiring diagram. You show four underfloor circuits being installed but you have eight solenoid valves which equates to eight circuits. Exactly how the the other components fit into the overall scheme is pretty much unexplained e.g how the pump is turned on, how the motorised valve and its associated limit switch is wired in, the controller etc. I'm also wondering if the pump output is completely dead headed (closed off) if all of the solenoid valves are off when these are independently controlled by a thermostat.

    • @SkillBuilder
      @SkillBuilder  10 หลายเดือนก่อน +2

      There is a wiring diagram. We can look at the electrics as a separate video but we don't like to overload the video. People switch off.

  • @josephmcdermott1338
    @josephmcdermott1338 9 หลายเดือนก่อน

    Hi as I understand you just laid the pipe up and down why not counter loope thanks joe

    • @SkillBuilder
      @SkillBuilder  9 หลายเดือนก่อน

      To achieve a snail pattern you need castelated trays.

  • @geoffc4771
    @geoffc4771 10 หลายเดือนก่อน

    Timely video Roger - I’ve got a beam and block floor with ~30mm eps insulation layer then a 70mm concrete screed. If I fit the low profile boards, am I going to loose all my heat to the cold cavity under the beams, or can I add an extra thin insulation layer or do I just stick with radiators - which option would you go for? Looking forward to your floor insulation video!

    • @SkillBuilder
      @SkillBuilder  10 หลายเดือนก่อน +1

      Always go for underfloor heating it is way better. You just need a pipe in screed system.
      40mm insulation and 60mm screed with fibres is good.

    • @dannyg2325
      @dannyg2325 10 หลายเดือนก่อน

      @geoffc4771 No, you will be fine. You’ve 70mm screed plus 30mm eps. 90% of the heat will rise, leaving about 10% being absorbed by the concrete floor.
      If you have enough head height in the rooms you can go for a slightly different setup, that uses insulated panels instead.
      But either way I think you should be ok.

    • @geoffc4771
      @geoffc4771 10 หลายเดือนก่อน

      Thanks for the replies - I’ll look a bit closer at the insulated boards - I would like to get 100mm pipe spacing to keep the temperature as low as I can go - not sure if the boards are available with that pitch?

    • @dannyg2325
      @dannyg2325 10 หลายเดือนก่อน

      @@geoffc4771 I have a Nuheat lopro 10 system. (10mm pipe) at 150mm spacing and run most of the year at 35°c flow

  • @Binkahoona
    @Binkahoona 10 หลายเดือนก่อน

    Hi, is there a sub floor under the timber flooring? Also is the heat coming from a system or combi boiler?

    • @SkillBuilder
      @SkillBuilder  10 หลายเดือนก่อน +1

      It is a combi but it is wired up to operate as a system boiler through a DHW cylinder. The combi hot water didn't deliver enough flow

  • @ooslum
    @ooslum 10 หลายเดือนก่อน +1

    2nd comment Roger. Wouldn't it be nice to have a square meter of a house dedicated to services, a mini plant room, the various techies that modern house do/will need don't have to sit on the floor in a corner ot teter on a ladder with a light bulb in the ear whilst working. Right, dream over.

  • @jsmeets88
    @jsmeets88 10 หลายเดือนก่อน

    Hi there Rodger,
    I will be straight forward with you... Where did you hide the mics in my house. Everytime I'm talking building plans with my wife a video pops up with the exact same topic. This can be something really mundane like a garden path to this underfloor heating. My wife even jokingly asks me all the time if the all hearing all knowing Mr. Roger can guide us to the path of diy. You're kind of a saint in our house haha! Keep up the amazing work.
    Greetings from the Netherlands!

    • @SkillBuilder
      @SkillBuilder  10 หลายเดือนก่อน +3

      you do know that your phone and other devices are listening all the time. We often play games with it. in my house. Mention holiday in Thailand and the adverts pop up.

    • @jsmeets88
      @jsmeets88 10 หลายเดือนก่อน

      So it's you who listens! Haha love it. Keep up the good work!

    • @Trev5
      @Trev5 10 หลายเดือนก่อน +1

      Good Joke: My wife asked why I always whisper in the house? I said that MI5 were listening in on our conversations...!! I laughed, the wife laughed and Alexa laughed.... 😮

  • @stuffoflardohfortheloveof
    @stuffoflardohfortheloveof 10 หลายเดือนก่อน

    Brill vid, fascinating. Thanks 👍

  • @liamwalsh209
    @liamwalsh209 10 หลายเดือนก่อน

    Get yourself some rothenberger adjustable spanner’s mate. Top man btw

    • @SkillBuilder
      @SkillBuilder  10 หลายเดือนก่อน +1

      I have some, I have way too many spanners and wrenches of all makes. Those plastic jaws make them too wide for that nut.

  • @nicholasgirard8246
    @nicholasgirard8246 10 หลายเดือนก่อน

    would you ever use electric under floor heating? and if so what brand would you use?

    • @SkillBuilder
      @SkillBuilder  10 หลายเดือนก่อน

      I have but only as tile warm up. It is a poor choice for heating a room. It costs a fortune to run

    • @nicholasgirard8246
      @nicholasgirard8246 10 หลายเดือนก่อน

      thanks for repling. I just saw you video on that. one look at at that long heating element and thought "nope" .cheers@@SkillBuilder

    • @nicholasgirard8246
      @nicholasgirard8246 10 หลายเดือนก่อน

      what would you say is the minimum depth for underfloor heating?@@SkillBuilder

  • @Swwils
    @Swwils 10 หลายเดือนก่อน +2

    It’s 2024, why is this dt11 and not a weather adjustive flow temp curve. Silly.

    • @SkillBuilder
      @SkillBuilder  10 หลายเดือนก่อน +1

      Because it is on a boiler that is not running on open therm and they have radiators in the rest of the house. You are wasting your time playing 2024 games. You need to know what applies where. That is the whole heat pump debate right there.

    • @Swwils
      @Swwils 10 หลายเดือนก่อน

      @@SkillBuilder what a shame.

  • @funkypotamus
    @funkypotamus 10 หลายเดือนก่อน

    Fantastic info. Thanks.

  • @mattcole6230
    @mattcole6230 10 หลายเดือนก่อน

    What's the depth of the UFH system Roger?

    • @SkillBuilder
      @SkillBuilder  10 หลายเดือนก่อน +1

      it can be as low as 15mm. Have a look at the underfloor heating website.

  • @JurassicJolts
    @JurassicJolts 8 หลายเดือนก่อน

    Good video

  • @ianscottuk
    @ianscottuk 10 หลายเดือนก่อน +1

    Hi
    Great video! Few questions-
    1. Why do you need a pump? Is the boiler pump not sufficient? Is this always the case or if it was a smaller area would it change?
    2. Is there a need to zone it? I am thinking of an upstairs bathroom, and i already have an upstairs zone.
    3. If you have floor boards would you still need to screed? Is it to ensure a level floor overall or just support each board so they don't crack? Would sanding the floor flat work?

    • @TooMuchInfoSir
      @TooMuchInfoSir 10 หลายเดือนก่อน

      Not a plumber but diy installing atm.
      1. Correct, and a pump per ufh manifold, per floor.
      2. No, but as per rogers damp vids, heat finds the cold, so just ufh in one room wouldn’t be sufficient to heat it if other rooms are off. Im not zoning at all (combi) and letting room thermostat control the valves for each loop. But all ufh and all rads have an ‘open’ system (in my design).
      3. You can get foam alternatives to these cement boards, also between joist solutions, talk to ufh provider for best solution for you.

  • @janm2510
    @janm2510 10 หลายเดือนก่อน

    Fantastic !

  • @therealdojj
    @therealdojj 10 หลายเดือนก่อน

    Got all my kit from the store but it would appear that my WiFi won't work with the stat 😔
    Worked fine with my Sky but when I switched to Virgin it stopped taking to the app 😔
    I've even got my kids to have a fiddle with it but to no avail 😔
    Anyone got a how to fix please?
    Thanks

    • @tommotube
      @tommotube 10 หลายเดือนก่อน

      Did you change routers when you switched internet provider (from Sky to Virgin)? If so, this is the likely cause. I'd buy a new decent router, which should get it connected again. As a side benefit, your WiFi signal will probably get much better!

    • @therealdojj
      @therealdojj 10 หลายเดือนก่อน

      @@tommotube yes, we did
      The virgin WiFi is so much better in our house than the sky one so I'm not sure what the issue is, same phone worked fine before and then just stopped connecting

    • @tommotube
      @tommotube 10 หลายเดือนก่อน +1

      Unfortunately some of the free routers just don't play nicely with internet connected devices

  • @ooslum
    @ooslum 10 หลายเดือนก่อน

    Listened twice Rog, still can't get how low, the low-profile is, it's probably me zoning out with my man cold, cheers.

    • @SkillBuilder
      @SkillBuilder  10 หลายเดือนก่อน +1

      Sorry
      I didn't say because there are different options. This one is 15mm but on the Underfloor Heating Store website there are also 20mm kits. www.theunderfloorheatingstore.com/collections/low-profile-water-underfloor-heating

  • @pitbladdoassociatesltd
    @pitbladdoassociatesltd 10 หลายเดือนก่อน

    I gather there is no furniture going into that room afterwards, as we know that there are certain furniture you just don’t want to be putting over underfloor pipes. For instance if that was a kitchen you wouldn’t be putting it under the fridge kitchen units etc. It’s the one thing that puts me off installing underfloor, and thats that once its in, you cannot change your floor plan really.

  • @remcopoepjes
    @remcopoepjes 10 หลายเดือนก่อน

    And use a electric valve on the system it zelf

  • @tombley5760
    @tombley5760 10 หลายเดือนก่อน

    Who's idea was the tossy "music"?

  • @morrisonmeister
    @morrisonmeister 9 หลายเดือนก่อน

    Everyone I know who gets underfloor heating is obsessed with telling everyone how they walk around barefoot on it, 4 weeks later they are all back wearing nice big soft fluffy slippers. Alternatively just plug an electric heater into a socket, if it breaks change it within 30seconds save yourself £1000's and never have to worry about expensive leaks, maintenance or blockages.

    • @SkillBuilder
      @SkillBuilder  9 หลายเดือนก่อน

      I have never had a leak on an underfloor heating system. It is way more effective than a radiator. I would not be without it.

  • @george-1961
    @george-1961 10 หลายเดือนก่อน

    My system needs updating and a good service. Wish you could come to Potters Bar in Hertfordshire Roger. The mixer has seized and the pressures not working properly and the floor has cold spots.

  • @fireblaster9961
    @fireblaster9961 10 หลายเดือนก่อน +1

    That switch said fountain....you just know theses people are minted

    • @SkillBuilder
      @SkillBuilder  10 หลายเดือนก่อน +1

      That fountain is for champagne.

  • @IanFarquharson2
    @IanFarquharson2 10 หลายเดือนก่อน

    There are 2 kinds of people when it comes to thermostats… the gene for understanding them is on the Y chromosome.

  • @accesszero4803
    @accesszero4803 10 หลายเดือนก่อน

    Low expanding construction foam is miles easier to lay the boards

    • @SkillBuilder
      @SkillBuilder  10 หลายเดือนก่อน

      There is a chance of movement on foam and the tiles will crack if you get more than 2mm deflection

  • @JustBadMeAndI
    @JustBadMeAndI 2 หลายเดือนก่อน

    That Wago box is much better, I don’t think we were ever allowed to use those old screw terminals where I am from.
    Btw, the uk house electricity system sucks, plugs are way too big, there’s no need for fuses in every goddamned plug or outlet.
    Nope, I am not a yankee, that’s on very other level, minimum stupidity but that’s an understatement.

    • @SkillBuilder
      @SkillBuilder  2 หลายเดือนก่อน

      You seem to be angry about it. The U.K system allows for the protection of appliances at the point of use. A circuit fuse is adaptable according to the total load but not an individual overload.

  • @mrsstaff78
    @mrsstaff78 10 หลายเดือนก่อน

    My husband’s brother and his wife have their thermostat set to 16C 🥶🐧🐧

    • @SkillBuilder
      @SkillBuilder  10 หลายเดือนก่อน +1

      Is that too cold. I am guessing they wear big jumpers.

    • @mrsstaff78
      @mrsstaff78 10 หลายเดือนก่อน

      @@SkillBuilder we wear thermals and jumpers when we go to their house

  • @johnrosenfeld
    @johnrosenfeld 10 หลายเดือนก่อน

    IntersI

  • @QnA22
    @QnA22 9 หลายเดือนก่อน

    How about Wall Heating? I understood efficiency is quite increased with it, but what about the effort, cost and installation? I got my info from this rather dry number crunching video : th-cam.com/video/FWhbcNpD-UQ/w-d-xo.htmlsi=f4nyI9upnEp_LUtB

  • @TheWaxChainFanClub
    @TheWaxChainFanClub 10 หลายเดือนก่อน +1

    In this day and age we should call them personifolds. Come on, Roger, get with the times.

  • @ohandanotheronebitesthedus6247
    @ohandanotheronebitesthedus6247 10 หลายเดือนก่อน

    What makes it low profile lol

  • @NikiK57
    @NikiK57 10 หลายเดือนก่อน

    "Turning it down from 23 to 21 or even lower in the kitchen" - why are Brits always setting their thermostats so low? I'm freezing when its below 23 :X

    • @SkillBuilder
      @SkillBuilder  10 หลายเดือนก่อน

      In a kitchen you are often moving around and cooking. If you can't stand the heat........turn it down.

  • @razorlicks7929
    @razorlicks7929 10 หลายเดือนก่อน

    Great explanation except those are actuators and not solenoids. They are heat motors not magnetic based like a solenoid would be.
    Keep looking at the spur that says fountain and wondering if they’ve used you before 😂😂

    • @SkillBuilder
      @SkillBuilder  10 หลายเดือนก่อน

      You are correct

  • @Mark-ob9bk
    @Mark-ob9bk 10 หลายเดือนก่อน +2

    Tidy job. Maybe not to the heat geek stanards but not all customers can spend 10k on their system.

    • @J.S.A.
      @J.S.A. 8 หลายเดือนก่อน

      £10k, my quote from them was £24k (including grant) And without the new tiles etc needed to actually have a floor 😂

  • @Joe-jv5mm
    @Joe-jv5mm 9 หลายเดือนก่อน

    Brilliant breakdown, loads of detail, like a 🧽 Soaking up all the Information 😉

    • @SkillBuilder
      @SkillBuilder  9 หลายเดือนก่อน +1

      Great to hear!

  • @remcopoepjes
    @remcopoepjes 10 หลายเดือนก่อน

    How bad this is so many heat disepating in undervloor and walls energie lost This is wasting energy Under floor heating is comfort heating and mostly don wrong if you use the distributed use a bypass. Regulated so There is directly hot water so the vloor is better heat more consistent