Why Did The Compressor Fail?

แชร์
ฝัง
  • เผยแพร่เมื่อ 28 ธ.ค. 2024

ความคิดเห็น • 32

  • @refer_insight
    @refer_insight 9 วันที่ผ่านมา

    I remember the video when you installed the accumulator on this system, great repair Dave.. I never trust those peanut LPC, had too many issues with them pulling into vacuum

  • @MariosACandRefrigeration
    @MariosACandRefrigeration 13 วันที่ผ่านมา +3

    button type lps,strikes again.nice work Dave.

    • @topher8634
      @topher8634 13 วันที่ผ่านมา +2

      Don't care for the encapsulated style either.

  • @ronaldclark8187
    @ronaldclark8187 10 วันที่ผ่านมา

    Good one Dave.
    It wasnt doing much work,not much amp draw either

  • @joelacosta3521
    @joelacosta3521 9 วันที่ผ่านมา

    Thanks for the video super tech. Also, she has a license to catch a fish 😂😂😂

  • @jamnben278
    @jamnben278 13 วันที่ผ่านมา +1

    I love those collapsible hoses! They are heavy duty, steel lined and I can carry about 400' up to the roof in one trip!

  • @OcRefrig
    @OcRefrig 13 วันที่ผ่านมา +3

    Good Video ! Yea, One thing bad about pump down systems. if L p. control fails causes all kinds of problems worst is compressor failure.
    Something to be said for just Knocking it off & on Temp control & a Contactor when it has an accumulator. no chance of failure. less parts. less problems.
    i'll bet u could sell those guys a Maintenance. Tell them you will swing by every 3 Months Vacuum Evaporator & Give system a once over.
    Clean condenser Every 6 Months or as necessary.
    Did u get a Chance to Replace the Contactor ?
    Good video.

    • @NorCal-refrigeration
      @NorCal-refrigeration  13 วันที่ผ่านมา +1

      @@OcRefrig new contactor yes. And yes I told them I need to do regular maintenance 🤘🤘

  • @thesilentonevictor
    @thesilentonevictor 13 วันที่ผ่านมา

    Good work Dave

  • @hvacboy5591
    @hvacboy5591 13 วันที่ผ่านมา +3

    New meter Dave? How ya like that milwaukee meter?

    • @NorCal-refrigeration
      @NorCal-refrigeration  13 วันที่ผ่านมา

      @@hvacboy5591 trying to get use to it. Not sure about it yet.

  • @williamgeyer4389
    @williamgeyer4389 13 วันที่ผ่านมา

    Nice video man!!!

  • @makeitcold6649
    @makeitcold6649 13 วันที่ผ่านมา

    I’m not a fan of the sweat in LP controls. Dual pressures are fine but I have been using the threaded ones with a core depressor for a long time now and change them and the core every 2-3 years or so during a maintenance. Haven’t had a leak or failure in ~12 years, I do the same with fan cycle and high pressure switches. Cheaper than a dead compressor at midnight. I also have wondered if I could get away from pumping down just using an accumulator and solenoid valve, not willing to experiment with a customer though

  • @FPHA697
    @FPHA697 13 วันที่ผ่านมา

    Way to go Dave i remember that one also I believe you had to use suicide cord to scab power. Thanks brother for the video keep rockin!!

  • @yinggamer7762
    @yinggamer7762 13 วันที่ผ่านมา

    If it was pulling in a vacuum for a while would the reformat you reused potentially be contaminated?

  • @AngelHVACR
    @AngelHVACR 13 วันที่ผ่านมา

    How do you like those Eli tech gauges so far ?

  • @topher8634
    @topher8634 13 วันที่ผ่านมา

    Good thing it didn't smoke the motor, running in a vacuum like that. It would've done whole lot more damage. Been noticing a lot of the recips are getting scarce too. Where I work we have a shit ton of alliance recips in split system A/Cs and the replacement is a scroll "kit". I'm sure the government has something to do with it.

  • @topher8634
    @topher8634 13 วันที่ผ่านมา

    Remember that one. You were out there most of the night. It was one thing after another.

  • @shine-cg9uf
    @shine-cg9uf 13 วันที่ผ่านมา

    👍🇺🇸💪❄️ go birds n flyers unfortunately fly guys got beat up yesterday

  • @alessichris07
    @alessichris07 13 วันที่ผ่านมา

    Was it always R448A

  • @harrydickson4575
    @harrydickson4575 13 วันที่ผ่านมา +1

    👍👍👍

  • @OswaldoLucioCenzi
    @OswaldoLucioCenzi 13 วันที่ผ่านมา

    Olá Dave. ABRAÇOS.

  • @throttlebottle5906
    @throttlebottle5906 11 วันที่ผ่านมา

    "Why did the compressor fail?" Because Dave worked on it instead of Hack and Moe? 🤪🤪

  • @jamminwrenches860
    @jamminwrenches860 13 วันที่ผ่านมา

    My guess is the years of abuse from the dirty coil caused flood back damaging the reed valves.

  • @jamnben278
    @jamnben278 13 วันที่ผ่านมา

    clogged coilititus

  • @fredflintstone8048
    @fredflintstone8048 13 วันที่ผ่านมา

    My shepherd is a hunter. She recently killed a rabbit who foolishly thought it could go through our yard. Big mistake. I've yet to take her fishing.
    My wife was keeping a few coy fish in a large plastic pond. One day we were late to get home and feed the dogs. The fish were gone. The pit bull ate them. The wife was angry. I had to work hard not to laugh at his resourcefulness.