Mene Reinforcement Coupler par aur bhi videos banaye hai , Jiski alag se PLAYLIST hai , AP " REINFORCEMENT COUPLERS " ke PLAYLIST me jakar dekh sakte hai , yadi iske alava apko kisi aur knowledge ki jarurat ho to use pura describe kare ki actually apko kis vishay par jankari chahiye ..
By the way, if your position of coupler comes at the junction then it is not a big deal. Well, for It's safety, the structure consultant keeps for a lap position( Zone-2) .
You must have seen two methods in this video. threading and forging; Threading and forging methods have different rates. If you are getting forging method done at your construction site, then you have to give separate rate to the contractor for reinforcement forging as mentioned in the video. In forging method, you have to give the rate of steel forging. There is no need to count the steel length separately. I hope you have understood. Revert in case of any query required.
@@civilkudos actually problem is that he is claiming length of rebar 30mm more at every coupler location, because during forging that 30mm is pressed and then will do forging, is this concept is right ?? Should we pay for him for additional 30mm
Good information.
Very nice bharat sir, well described content hats off.
Bht bdiya
Sir very nice content. 👏👏👏👏👏. I really appreciate for your well done work. 👏👏👏💯💯💯💯
Thanks👍
Sir really informative 👍 thank u Bharat sir
Very nice sir 🙏🙏
Nice information sir❤
Sir please make video on different tests of coupler.
I have Share , Please Watch.😊
Kindly provide a complete information vedio on MBT cupler with costing comparison..
Aapko mila kya sir cost comparison ?,
Namasta sir. 1st floor k upar 16mm steel bar 6 inch to 1foot tak chora jata ha to coupler use kar sakta hai? Iskaa upar ek video laye.
Please share the testing procedures of coupler in site as well as in lab
Please Visit my Reinforcement Couplers Playlist.
In which I made Coupler's testing procedures.
👌👌👌👌👌👌👌👌
Want to know the testing of slip test
Sir column mai coupling ka position kya hai
What is the market cost of this coupler with same IS Specification
Sir one coupler to 2nd coupler distance kitna hona chahiye....
Sir coupler Ki testing.pe video bnaye
Mene Reinforcement Coupler par aur bhi videos banaye hai , Jiski alag se PLAYLIST hai , AP " REINFORCEMENT COUPLERS " ke PLAYLIST me jakar dekh sakte hai , yadi iske alava apko kisi aur knowledge ki jarurat ho to use pura describe kare ki actually
apko kis vishay par jankari chahiye ..
sir what should be the position of couplers in column reinforcement and it is ok in column beam junction or not..?
By the way, if your position of coupler comes at the junction then it is not a big deal. Well, for It's safety, the structure consultant keeps for a lap position( Zone-2) .
Sir coupling zone kya hota hai
Side hai kya koi threding wark ka sir
please visit my reinforcement coupler playlist
Sir position kya hota column reinforcement ka
Sir , Reinforcement Coupler ke 3 parts hai ap vah sabhi dekhe .
I hope apko sabhi savalo ka javab milega. 👍
Sir I have a question, our site contractor claimed extra length for forging in column rebar , is it claimable??
You must have seen two methods in this video. threading and forging; Threading and forging methods have different rates. If you are getting forging method done at your construction site, then you have to give separate rate to the contractor for reinforcement forging as mentioned in the video. In forging method, you have to give the rate of steel forging. There is no need to count the steel length separately.
I hope you have understood.
Revert in case of any query required.
@@civilkudos actually problem is that he is claiming length of rebar 30mm more at every coupler location, because during forging that 30mm is pressed and then will do forging, is this concept is right ?? Should we pay for him for additional 30mm
@@maheshj660 , No, you don't have to do that. You only have to pay the rate of forging. There is no need to give any extra length.
@@civilkudosthanks sir for ur valuable advise...
Please make 1 video regarding bend deduction as per IS code 1d or 2d,... Thanks making such informative videos
sir plzzz videos upload kijiyega
I have made Reinforcement Coupler playlist - " Reinforcement Coupler "
Whatever you want to know about , you will find it there
want coupler service pls share contact