- OpticStudio provides a lot of analysis features to help you identify the performance of your system. In this webinar we will discuss the features that spot the aberrations of your system:
Focus
Distortion
Astigmatism
Coma
Spherical
Field Curvature
Interested in using OpticStudio, Download the Free Trial: ow.ly/10mQJz
Check out more information about zemax here: ow.ly/10mQSD - วิทยาศาสตร์และเทคโนโลยี
Fantastic video! This information is exactly what I needed, and I really appreciate all the aberrations, and their tell-tale signs, being listed in a plot at the end.
This is amazing, Thank you very much!
Thank you very much for this information.
Loved it, thanks
Is the Siedel diagram for the centre of the optical system or an average over the entire field ?
Seidel coefficients are calculated with chief and margial rays only. Only the vertex power of the optic is considered. The chief ray sits at the outermost field angle, so in that sense the entire field of view is considered.
The Seidel graph is only useful for rotationally symmetric systems dominated by third order aberrations.