Sir, as per AWS D1.1 section 6 part F 6.22.7.1 transducer frequency SHALL be between 2 to 2.5 MHz and under 6.22.7.1 the transducer dimensions SHALL be 15mm to 25mm in width and 15mm to 20mm in height....
Dude, u need to verify if the probe is really refracting 70 degrees of shear waves. Since ur doing this full video right from the scratch and hence its advised that u verify the angle first before you do ur velocity and wedge delay calibration
If possible than upload a video of Weld UT having defects and tell how to identify nature of defect(i.e LOF, Porosity,Slag, Lop
What is the purpose of 3mm width and R25 curve
Sir, as per AWS D1.1 section 6 part F 6.22.7.1 transducer frequency SHALL be between 2 to 2.5 MHz and under 6.22.7.1 the transducer dimensions SHALL be 15mm to 25mm in width and 15mm to 20mm in height....
Dude, u need to verify if the probe is really refracting 70 degrees of shear waves. Since ur doing this full video right from the scratch and hence its advised that u verify the angle first before you do ur velocity and wedge delay calibration
please the position of hole in the calibration v1??? , merci
Telling everything wrong.first verify probe angle , probe infex then varify beam path length from two echoes
i didn't understand anything
Sir hindi me audio dubbed kijiye plsss for better understand..
I didn't understand anything other than D1.1
very bogus video forever i see