Super bro.. In power plant some few engineers, wantedly junior engineer ko knowledge share nahi kartha he. Your doing great job. This is full more usefull for new Engineering trainees in power plant. According to my experience. Don't take wrong.
@@ElectricalTalks Sir mujhe alternator ke subject me ek discussion karna he ap. Actually me clear nahi ho pa Raha hu doubt me hoo. Sir mera doubt clear kar dijiye. Ap se meri baat ho pati to me wo question ap se puchh pata Me power plant me kam karta hoo Bahut jhaan se jaan ne ki par clear nai ho paya hoo.
@@ElectricalTalks Sir mujhe alternator ke subject me ek discussion karna he ap. Actually me clear nahi ho pa Raha hu doubt me hoo. Sir mera doubt clear kar dijiye. Ap se meri baat ho pati to me wo question ap se puchh pata Me power plant me kam karta hoo Bahut jhaan se jaan ne ki par clear nai ho paya hoo.
Sir sub harmonium injection ko synchronised condition mein use kr sakte h kya????? Kyu ki generated voltage ke samne apn chotasa injected voltage tik nahi payega na???
This voltage drop is very useful...used to find out if there is any stator earth fault or not. Don't worry 😀. The amount of voltage drop is very small. Now, can you tell me why this voltage drop is very small in no fault condition?
Super bro.. In power plant some few engineers, wantedly junior engineer ko knowledge share nahi kartha he. Your doing great job. This is full more usefull for new Engineering trainees in power plant. According to my experience. Don't take wrong.
Good explanation sir. The way you explain seems like you are a power plant specialist.
🤣🤣🤣 Thank you so much
Really it’s first time I understand the protection
Sir as per my knowledge the for 12 volt setting the ratio of NGT should be
15.75/√3/240 V
Excellent explanation Sir. Thanks 👍
But apart from that your explanation is wonderful. Your knowledge level is excellent
Story ka hero to Generator hai
But Ap to Electrical ka hero he 😃😃😃
Ha Ha Ha 🤣. Good sense of humor...
@@ElectricalTalks Sir mujhe alternator ke subject me ek discussion karna he ap. Actually me clear nahi ho pa Raha hu doubt me hoo. Sir mera doubt clear kar dijiye.
Ap se meri baat ho pati to me wo question ap se puchh pata
Me power plant me kam karta hoo
Bahut jhaan se jaan ne ki par clear nai ho paya hoo.
@@ElectricalTalks Sir mujhe alternator ke subject me ek discussion karna he ap. Actually me clear nahi ho pa Raha hu doubt me hoo. Sir mera doubt clear kar dijiye.
Ap se meri baat ho pati to me wo question ap se puchh pata
Me power plant me kam karta hoo
Bahut jhaan se jaan ne ki par clear nai ho paya hoo.
Question kya hai bolo... Agar mera concept clear raha us topic pe, answer dene ka pura try korunga. 😊
You may e mail me or ask here also.
Sir, thanks to sharing your knowledge... its equivalent to organ sharing..
Sir 20hz principle main band pass filter ka output kitna hota hai
Mastertrip relay like micom, ABB 545 and or siemens uses which one? 100% stator earth fault protection or 95%
Smart working Thank you sir
You are welcome
Sir sub harmonium injection ko synchronised condition mein use kr sakte h kya?????
Kyu ki generated voltage ke samne apn chotasa injected voltage tik nahi payega na???
Why Third Harmonic Detection doesn’t operate in middle region of stator winding ?
sir...please explain why alternator has 9 terminal at outlet
3 for phase side
6 for neutral side
Sir kitna voltage inject karega value kaise find out karenge
There are predefined set for voltage in relay
Why unbalance due to earth fault cannot ve detected using sequencial component neg seq current or why differential relay cannot detect this .
3rd harmonica voltage how measuring accross the neutral?
Sir, kya voltage direct measure karega....... Resistance ka kya use hai...... Please clear doubt
Are you talking about NGT resistance?
@@ElectricalTalks yes sir, will no any voltage drop across resistance?
This voltage drop is very useful...used to find out if there is any stator earth fault or not.
Don't worry 😀. The amount of voltage drop is very small.
Now, can you tell me why this voltage drop is very small in no fault condition?
Sir, why we use 20Hz frequency injection, why not 30Hz, 40Hz or 50Hz. please explain
Can you please help us understand Generator differential protection
Already explained...
Relay setting par video banaye.
ok
Excellent
Bahut accha
When earthfult standby relay operat?
Why bank pass filtration use.
What's working principle.
How much volts use
generator protection ka ek concise video b bna dijiye please, interview me answer krne k liye
Ok
Pehelaa story es type kaa video youtube per peheli waar dekhaa...
Make videos for all generator protection
I will try for sure
sir if 100% earth fault cover full protection, then why use 95%
Phase voltage itna kesea aaeega sirr
Sir please make a vdo details about 1st and 2nd stage rotor earth fault.
Next video might be on that
@@ElectricalTalks thank u sir
Sir plz upload english version
please recalculate, NGT rating should be (15.75/1.732) / 240V, also your current calculation is wrong value should be 7.6V not 3.8V.
Sir सभी जनरेटर प्रोटेक्शन का विडियो बनाए
I will try for sure brother
पुरा इलेक्ट्रिकल्स विडियो बनाए
Transfor calculation 7.40 min is it calculation value is 3.8 volt i just calculated it and its value is 7.62 volt