Correction "Hello everyone! I want to address a mistake that occurred in the video at the 5:11. I apologize for any confusion caused. Upon reviewing the footage, I noticed that I incorrectly connected a wire from terminal 1 of the Phase Failure Relay to the common terminals 95 and 97 of the Overload Relay. The correct wiring should have involved taking the wire from terminal 3 of the Phase Failure Relay. I deeply regret this oversight. To ensure the proper functioning of the system, please disregard the wiring shown in the video and follow the corrected connection mentioned earlier. I apologize for any inconvenience caused, and I appreciate your understanding and patience. If you have any further questions, please don't hesitate to reach out. Thank you for your support!"
3 phase and 4 wire VPRD2M relay module not switching on properly, which is preventing you from configuring your 3-phase star delta pump motor. and when I connected the panel system with the supply the N to L readings are 390-400 Voltage, the expected value for L to N is 230 volt, and When I measured the supply prior I connected to the panel is 400 voltage. Illustrate in brief what is all the reason behind the wiring of the control panel?
Hi @tesfud1, sorry for the late reply. Thank you for sharing your issue. If your problem is still not solved, please feel free to contact me directly so we can troubleshoot further. I'd be happy to help you resolve the issue.
Correction
"Hello everyone! I want to address a mistake that occurred in the video at the 5:11. I apologize for any confusion caused. Upon reviewing the footage, I noticed that I incorrectly connected a wire from terminal 1 of the Phase Failure Relay to the common terminals 95 and 97 of the Overload Relay. The correct wiring should have involved taking the wire from terminal 3 of the Phase Failure Relay. I deeply regret this oversight.
To ensure the proper functioning of the system, please disregard the wiring shown in the video and follow the corrected connection mentioned earlier. I apologize for any inconvenience caused, and I appreciate your understanding and patience. If you have any further questions, please don't hesitate to reach out. Thank you for your support!"
3 phase and 4 wire VPRD2M relay module not switching on properly, which is preventing you from configuring your 3-phase star delta pump motor. and when I connected the panel system with the supply the N to L readings are 390-400 Voltage, the expected value for L to N is 230 volt, and When I measured the supply prior I connected to the panel is 400 voltage. Illustrate in brief what is all the reason behind the wiring of the control panel?
Hi @tesfud1, sorry for the late reply. Thank you for sharing your issue.
If your problem is still not solved, please feel free to contact me directly so we can troubleshoot further. I'd be happy to help you resolve the issue.