Hi, this is Arun Kumar. Super excited to share our official WhatsApp Channel⬇️ whatsapp.com/channel/0029Va9qEpnADTOFTuic4p16 We’ll Get You Updated About New And Upcoming Water Purifier, Spare Parts,, And Many More Intersting Content, So come along and join my channel. ♥️ Love & Prayers, Arun Kumar RO TECHNICAL XPERTS
sare dimag vale technician youtube per hai baki hamre ghr pr jo aate h vo ro system or kharab kar dete hai isliye ab khud sikhna pad raha h. bahut aache se bataya sir aapne basic clear ho gaya . thank you for sharing knowledge with us 🙏🙏🙏🙏🙏🙏.
Naya LED light RO mein lagaya hai....blink kar Raha hai. Please share kare apka views. 3 UV LED light lagake dekha. Sab blink kar raha. SMPS ka DC side se connection kiya hai. Samajh mein nahi aa raha hai SMPS bhi new lagaya hai
So I'm trying to make a uf+uv water purifier so..in this case I won't be needing the pump..So can I connect the uv lamp directly on the smps or do I need a uv choke.. please help.. thank you
UV - yes choke is mandatory for UV lamp not for LED and choke available for both ac and dc you can use any one as per use SV - SV also comes with ac and dc so in this case if you are using ac choke use ac SV and if you wish to add SMPS then you can use dc SV and dc UV choke For any query feel free to call me 9168810786
Sir ji... Ek help kariye meri maine saare filters or RO membrane aur SV sab naye lagaye hain or FR bhi Naya lagaya Hai 450 ka.... Mera RO band honey k baad bhi waste pipe se boond boond paani tapakta Hai... Generally yeh issue SV valve Agar kharab toh hota Hai ya kahi kisi pipe me air ban rahi ho toh hota Hai... Par yeh issue nahi Hai... Aur SV Bhi bilkul Sahi Hai for bhi pani tapakna band nahi ho raha hai... Plz kuch suggest kariye... Aabhar 🙏
@@ROTECHNICALXPERTS sir ji woh bhi check Kia tha pehle hi step by step.... Kuch samajh nahi aa raha hai ki kaha dikkat Hai aisa problem pehle kabhi kahi Dekhi nahi... Jaha Dekhi waha SV ka issue hi hota tha... 😟
There is another solenoid switch which stops the RO, the moment under counter tank (12 lts white drum) is full. It has no provision for a float switch. So how do we connect it in the circuit.
Sir adopter or smps m kya anter hota h or adopter ka b ase hi connection hota h kya ji sir or k parts ka asli name k bare m b video bnaye or filter ka in or out kaise ptta kre
Hi, this is Arun Kumar.
Super excited to share our official WhatsApp Channel⬇️ whatsapp.com/channel/0029Va9qEpnADTOFTuic4p16
We’ll Get You Updated About New And Upcoming Water Purifier, Spare Parts,, And Many More Intersting Content,
So come along and join my channel.
♥️
Love & Prayers,
Arun Kumar
RO TECHNICAL XPERTS
sare dimag vale technician youtube per hai baki hamre ghr pr jo aate h vo ro system or kharab kar dete hai isliye ab khud sikhna pad raha h. bahut aache se bataya sir aapne basic clear ho gaya . thank you for sharing knowledge with us 🙏🙏🙏🙏🙏🙏.
Mai bhi youtube se sikh gaya aasan hai aur servicing ka bhi kharcha bach gaya
Apko is video se sayad mujhe ek nayi rah mil gayi hai thank u so much sir 🙏🙏🙏🙏
thanks sr aapne bhot achche se smjhaya syed aapke btaye hue wairing se seekh sakoo
Very good teaching method need not to repeat to learn again please teach all type of ro repair
Dear, Aapka awaz audible nhi tha, Magar aapne explain bahut achhi tarah se kiya. Nice video 👍
Good demo 👍 sir.
Very Very Good... information Sir
Good job videos
Ache Tarah se samaj Aaya Thanks for guidance
Very well explained...keep it up ❤
Very nice just osam I like that video
Nice viedo sir 🙏 but. livpure ke naye modal par viedo banayye. I request you sir. Plz🙏
Soon
Good wring sir
Good Work of You...
Nice video
Verry good explained Sir I am fan of you.goood
👍👍😊🙏
Excellent sir.
Sir jo apne float ka connection k liye 2 wire nikale us thimble ko float valve me kisi ko kisi point me lga skte hain kya plz reply 😮
Good information about ro wiring connections
👍
Very nicely explained. God bless you my dear.
Sir per minute uv se kitna litre pani jana chahiye for home uv uf
Eske sath hi autoflush kit ki wiring batao sir plz
Ok
sir v good UV Chock kaya hota hai pls answer
Very nice sir🙏🙏👍👍
Very good information
👍👍
Sir iski wayring me vi SMPS ka ji DC boltej me vi. + . -. Dekhana padta hai
Super
Sir agar aap low pressure switch lagate to fir connection kaisa hota please 🙏 sir iska ek video zaroor laaye . Bahat hi zaroorat hai us video ka.
Channel pr upload hai, dekh lijie
Pasnd to ayi hai......
Aise he bnate rhye vdo.......
Floatvalve ko AC se connect karna hai ya 24v dc ko
Kisi se bhi kar dijie
Nice information thanks
Smps ke output me 2 black wire hote hai upr ek white line hai. To wo phase hota hai kya?? Use Phir pump ke red se Connect krna hota hai ya black se?
Black ground black white phase..... Also use meter for proper check
Sghhhj
Black line wale ko pump ke red wire se connect karo
😂😂 bklol black white phase hota h 😊@@rampraveshmishra5358
Very very good good
Good information sir ji
Good Bhai mera r o khat khat ki awaaj kar raha hai help plz
Pehle to agar ro mai lp laga hya hai to paani ka pressure check kijie,
Sir ji Livepure touch 2000 ki electric wiring ka circuit diagram agar aap de pate to acha hota.
Float valve ka wiring clear dikho yar
Clear video uploaded hai channel mai dekh lijie
sir video main aap ne flute wal ka wire ac se connect kiya hai mujhe ye janna hai kya ye kaam krega koi nuksan to nahi hoga
Yeh UV light kyu lagai isme ... Or kitna jaroori h yeh UV light lagana.. ??? Plz reply
Naya LED light RO mein lagaya hai....blink kar Raha hai. Please share kare apka views. 3 UV LED light lagake dekha. Sab blink kar raha. SMPS ka DC side se connection kiya hai. Samajh mein nahi aa raha hai
SMPS bhi new lagaya hai
good 👍
Main wiring ki video dekh li hai
bhai ro me pump or magnet switch tiktik kar raha hai or spms light blink kar raha , kabhi kabhi on off karne par sahi chalne lagta hai
Sir filter Pambu ki video banaen
Means( sorry mai samjha nahi
Sir float valve ka connection smps ke baad dc me bhi to kar sakte h??
So I'm trying to make a uf+uv water purifier so..in this case I won't be needing the pump..So can I connect the uv lamp directly on the smps or do I need a uv choke.. please help.. thank you
Another question..since Pump won't be there how will I connect the solenoid valve?
UV - yes choke is mandatory for UV lamp not for LED and choke available for both ac and dc you can use any one as per use
SV - SV also comes with ac and dc so in this case if you are using ac choke use ac SV and if you wish to add SMPS then you can use dc SV and dc UV choke
For any query feel free to call me 9168810786
Namaste. Ek doubt. Aap Float valve AC current se deter ho kiu current shock maar sakte. DC se qu nahi deter ho? Please reply
Dear sir motor pump ka dam kitna ?
RO ka filter to sab log aasani se bata dete h kaha milta h panel koi nhi batata h ki milta h ya nhi is pr bhi koi video banaye aap sir ji plz
booster pump ke red wire me smps ki positive wire hi lagani he ye bhi dhyan rakhe.
Assemble ke bare mein bataiye
Flut ko Dc nhi de skte kya
Yes
UV ka barrel dikhaya hi nahi? Round barrel me toh fit hoga nahi. Iska konsa barrel aata hai.
Sir SMPS me -/+ hota hai do no cable to back hai as me - kon sa + kon sa hai
- balck and + white and balck cable
Xx
LED ka kya kaam hota hai sir.
Led for uv chember
Some bacteria bach jata haii after membrane usi ko kill them 😊
Sir kya DC Ka flot switch NH lga sakte hai kya
Yes
Where can i but this type of cabinet let know
Aap isme LP switch q nahi lagate kuch reason bata sakte?
Nice sir
Float ko dc mein chalana safe rehta hai...
Sir pyping ka ek vedio banaiye please
Already banaya hua hai
Sahi
Sir ji... Ek help kariye meri maine saare filters or RO membrane aur SV sab naye lagaye hain or FR bhi Naya lagaya Hai 450 ka.... Mera RO band honey k baad bhi waste pipe se boond boond paani tapakta Hai... Generally yeh issue SV valve Agar kharab toh hota Hai ya kahi kisi pipe me air ban rahi ho toh hota Hai... Par yeh issue nahi Hai... Aur SV Bhi bilkul Sahi Hai for bhi pani tapakna band nahi ho raha hai... Plz kuch suggest kariye... Aabhar 🙏
Sv again check kijie
@@ROTECHNICALXPERTS sir ji check kai baar band honey k baad Sv output se pani nahi nikalta Hai ek boond bhj
@@ROTECHNICALXPERTS sir ji kuch suggest kijiye kaise hogi problem khatm yeh..
Adopter la point chek karo jo s.v. mai jata hai
@@ROTECHNICALXPERTS sir ji woh bhi check Kia tha pehle hi step by step.... Kuch samajh nahi aa raha hai ki kaha dikkat Hai aisa problem pehle kabhi kahi Dekhi nahi... Jaha Dekhi waha SV ka issue hi hota tha... 😟
There is another solenoid switch which stops the RO, the moment under counter tank (12 lts white drum) is full. It has no provision for a float switch. So how do we connect it in the circuit.
If float switch connection is linked to 220v both positive and negative , how will the pump, SV and UV strip switch of.....😇
Dear sir membran change kiya tho fr bhi change karna padta hi kaya aur 80 GPD ka membran hai tho FR KItaneka hona chahiye please help me and Ripley mi
4 time multiply by membrane gpd
My uv old. Tubelight l not out in uv candel ..I buy new LED uv light ....so Dada now what am doing ? How can change now
Mera SMPS kharab ho gaya hai kaise Banta hai aur kitna ret hai
Motor pump made in India,?
Very nice
Thanks
Thanks bro
Sir adopter or smps m kya anter hota h or adopter ka b ase hi connection hota h kya ji sir or k parts ka asli name k bare m b video bnaye or filter ka in or out kaise ptta kre
Please reply sir
Vv
Very nice sir thanks
Thanks sir
Very good information....
Nice Sir....
Sir mujhe r.o. ka Kam krna h
Sir mujhe Kam sikha skte h
Filter ka Bara bataya
TDS Kitna Hona chahiya BHI
250 tk ok rahta hai agar aap ko paani ke taste ae koi problm na ho toe
@@ROTECHNICALXPERTS bro kese pta lge GA ki ro Ka. Kon c item khrab h
TDS kaise shit Karana
Hello sir
सर जि हमारा आरो बंद होगया है
We can't total connection dc
I'm Kent ro technician sir kyu market ki band baja rahe ho Jab sab customer Jaan hi jayega to hum log kaha jayege please sir ye mat banao
same..hamari dukan bandh karwaenge ye gentleman 🤣
Sir,. AP. Aachha. DIKHAYA SIKHAYA. But. It is main FALT Galat. Kiya. Apne. Poora. Install. Wiring. Nahi. Kar. Aadhoora. SIKHAYA. Poora. Karo. End. Please. Next. Send. U tube. I waiting. SK. Singh. 9340832358
Where is the Circute diagram ?
Bhai sab..aap ne apne haath ka poora video banaya..ya wiring ka...apko amera wiringk upar lagana tha..👎👎👎
सर जि कनेकटीग कहा मिलेगा
Kya jaankari chahiye aapko
Aapka whatspp number mujhe dijiye, orbi easy taroka se dikhaye +smps+auto chock+lp+sv+vu+pump,,
uv on krke na dekhen , its breaks your dna , its cause cancer
full kits kanha milega?
9002071730
Your teaching knowladge poor do improve and long video not require. Make short video pin point.
Apaka mobile number bhejo na sir
9810687476
Very nice
🙏
Subscrib, share, like, bell icon and press all, video milti rahegi
Thanks Sir
👍👍