Super use full video.bro.....but enaku 410a gas .32 gas na payam so ..I'm working only r22 gas bro..but unga video patha thairiyam varudhu bro..tq for video..bro
Bro super informative video ,sharing your experience thank you . 1)Bro nitrogen leak test,afterwards vacuum then chagerging 2)safty belt use please 3)video clearly good 👍 your experience and explanation super, I hope you will make more videos and share thank you so much I learn some missing things
Bro, your explanation is good. You could have insulated the copper tubing (outer covering is worn out as seen in the video). Cooling will be much better in such case as you have already done gas recharging. Then only it can be called a complete job. Just my suggestion to my friendly brother!
So much good work but then you use a file on the copper tube before flaring... you will just increase the chance of something going wrong by introducing metal shaving contermination.
வாழ்த்துக்கள் 👍 இன்று நான் பார்த்த வேலையில் hitachi ac R410a இந்த ac ல் error காண்பிக்கவில்லை ஆனால் சில நிமிடங்கள் கழித்து outdoor offஆகி விடுகின்றது பிறகு திரும்ப அதே போல் ஒட ஆரம்பித்து பிறகு ஆதே போல் ஆகின்றது இதில் மூன்று காரணங்கள் ஆனால் கஸ்டமர் வாரன்டியில் உள்ளதால் நான் சொல்லிவிட்டு வந்துவிடடேன் sensor and pcb பழுதாக காரணம் உள்ளதா
500 micron varaikum vaccum podanum. But micron gauge en kita illa.. So deep vaccum only.. Domestic ac la high side service valve irukathu.. So low side only vaccum pump connect pana mudium.
Enga vitula 940 tds, proven ro+uv+uf+active copper filter+tds controller with mat (mineral addition technology) water purifier - 12l.entha model podalama???
R22 ku gas charge panrappa onnu secksan la enonnu vacom pump la 2 tube pottu vacom podurom r410a la yathukku na gas drum la yathukku na oru tube pottu erukingga
R-22 60 to 70. 150 to 155 R-410 110 to 120 225 to 230 R134a. 12 to 15 85 to 90 R-600a. Below 0 to 1. 40 to 50 R-32. 110 to 115. 240 to 245 R-407c. 70 to 80. 180 to 185 R-404a. 80/30. 180 to 185 R-290. 65 to 75. 125 to 130
Hi sir. Ennoda Bluestar 1.5 ton ac ithe mathiri rat kadichu complete damage aagiruchu. then local la service panni ipo nalla run aaguthu. aana evlo cooling aanalum compressor cut off aagave matenguthu sir. service varavunga thermostat sensor um change pani pathutanga. aana problem sari aagala. matha padi ellam correcta irukuthu. ithuku enna sir panalam?
Check the connection first. Then check the relay. If relay is stuck the outdoor starts immediately whenever you turn on your ac. Just checkout or else the relay control is gone.
Excellent job 👍
Super use full video.bro.....but enaku 410a gas .32 gas na payam so ..I'm working only r22 gas bro..but unga video patha thairiyam varudhu bro..tq for video..bro
Bro super informative video ,sharing your experience thank you .
1)Bro nitrogen leak test,afterwards vacuum then chagerging
2)safty belt use please
3)video clearly good 👍 your experience and explanation super, I hope you will make more videos and share thank you so much I learn some missing things
Bro, your explanation is good. You could have insulated the copper tubing (outer covering is worn out as seen in the video). Cooling will be much better in such case as you have already done gas recharging. Then only it can be called a complete job. Just my suggestion to my friendly brother!
Thanks for your suggestion brother..
Dude put metal shavings in the pipe... the AC is dead by now.
Also where is micron gauge to see negative pressure? He only used a charging gauge... he can not see vacuum on it.
Anna ungga vedio romba help full ah erukku na
So much good work but then you use a file on the copper tube before flaring... you will just increase the chance of something going wrong by introducing metal shaving contermination.
Thanks for your suggestion..
Super Super Great post man Sri Lankan s.sasikumar
So ongada video semma super erudhuchi bro 👍👌👌👌❤
Bro your manifold gauge set & weight scale & charging hose adapter ,price & buying link pls share its very usefull ...thank you
வாழ்த்துக்கள் 👍 இன்று நான் பார்த்த வேலையில் hitachi ac R410a இந்த ac ல் error காண்பிக்கவில்லை ஆனால் சில நிமிடங்கள் கழித்து outdoor offஆகி விடுகின்றது பிறகு திரும்ப அதே போல் ஒட ஆரம்பித்து பிறகு ஆதே போல் ஆகின்றது இதில் மூன்று காரணங்கள் ஆனால் கஸ்டமர் வாரன்டியில் உள்ளதால் நான் சொல்லிவிட்டு வந்துவிடடேன் sensor and pcb பழுதாக காரணம் உள்ளதா
Sensor problem irukalam. Amps check pani pathingala..?
amps check பன்னவில்லை amp meter fault உள்ளது இதை பற்றியும் உங்கள் சேனலில் விலக்கமாக போடுங்கள்
Good information bro . Safty ah work pannunga bro . 2times shock aita 😲 2.40. Cerful bro. Video good 👍.......
Ellarum ipidi pana nalla irukum 😊.
எது அது போல்டு ah நட்டுji அது 😂 புதுசா 🤔
பொல்டு 🙄 நட்டு.? 👌
மிக்க நன்றி
Liquid gas charge pannuna gas vapour marum pothu pressure variable agatha fulla liquid charge pannalama
Liquid charge than pananum bro.. Pressure perusa difference irukathu.. 410a =r125+r32 mixing gas.. So blunded.a charge pananum.na liquid charge than pananum.
second hand ac la outdoor 1.5ton potu indoor 1ton podalamnu soldranga apdi pannalama yethum problem varuma...
Bro good tib but compressor la refrigerant liquid ah pogakudathu ana 410a liquid ah tha charge pannanum why?explain bro!
Bro r410 top up pannakoodatha. Complete eduthuttu puthu gas fill pananuma
Yes.. Vaccum pani gas charge pananum.
Vacuum pannum pothum gas charge pannum pothum unit on la irukkanuma illa off la irukkanuma bro
Bro kindly request to u use safety belt for outdoor working
And don't stand on the window cover... it's only for rain protection and can easily fall off.
Bro ethana microns varaikum vacuum panuvinga. High side vacuum panakudatha
500 micron varaikum vaccum podanum. But micron gauge en kita illa.. So deep vaccum only.. Domestic ac la high side service valve irukathu.. So low side only vaccum pump connect pana mudium.
Hi my name Thiyagu your video is good
Enga vitula 940 tds,
proven ro+uv+uf+active copper filter+tds controller with mat (mineral addition technology) water purifier - 12l.entha model podalama???
Ji reply pannunga
Podalam bro.. But ordinary Vida athigama vela vaikum.
Bro na flare nut ah kalattum bothu oil Maathiri konjam velila adichuchu athu enna bro !?
Excellent video bro.thanks you so much
நல்ல விளக்கம் சகோ
R22 ku gas charge panrappa onnu secksan la enonnu vacom pump la 2 tube pottu vacom podurom r410a la yathukku na gas drum la yathukku na oru tube pottu erukingga
Bro inverter ac apt 11 amps etukum bro 6 amps Kula tha irukum bro
Samaya sonniga bro💗👍
Outdoor la irunthu hose ah disconnect panratha kamikalaiyay bro
Next video la pakalam.
Your Good knowledge person kup
410 gas filling price evlo agum anna
Hii bro..,
R410a gas top-up pannalamaa illa Full top-up than pannanumaa.. please explain..
Full top _up tha pannanum
R-410A Gas refill panrathukku price yevlo bro!!!
DC inverter ac அதை பற்றிய பதிவு போடுங்கள்
Gas charging panna kola 2ndu well um open panni kondu than gas charging panra bro enaku idhum konam sella elum aah bro
Bro 410a charge pannum pothu suc dis service valve open panni thane pannuvenga
Yes.
Super Video BRO
Excellent good explanation bro thanks
Your vedio very good
Good explanation superb 👌
Amps rating parunga unit specification la... 11amps la varathu
nice video can u tell your ac service place
Trichy
1.5 ton whirlpool normal ac ku yeavlo amps varanum...410agas
7 amps
Bro onida AC 1 ton gas charge solluga gas R410a ok va
Vacuum eppadi proper ah podanum brother ...?
Make video soon
Ac outdoor la gas illa leakage problem ana Enna gas nu theriyala eppadi confirm panrathu sir
Outdoor cover remove pani compressor sticker parunga.. Athula mention panirupanaga
R22,R32,R410 back pressure reading slu ga bro
R22, back pressure 60 to 70
R32 back pressure 110 to 115
R410 back pressure 120 to 130
I hope it's useful for you
R-22 60 to 70. 150 to 155
R-410 110 to 120 225 to 230
R134a. 12 to 15 85 to 90
R-600a. Below 0 to 1. 40 to 50
R-32. 110 to 115. 240 to 245
R-407c. 70 to 80. 180 to 185
R-404a. 80/30. 180 to 185
R-290. 65 to 75. 125 to 130
Dear bro pls use safetty belt
Hi sir. Ennoda Bluestar 1.5 ton ac ithe mathiri rat kadichu complete damage aagiruchu. then local la service panni ipo nalla run aaguthu. aana evlo cooling aanalum compressor cut off aagave matenguthu sir. service varavunga thermostat sensor um change pani pathutanga. aana problem sari aagala. matha padi ellam correcta irukuthu. ithuku enna sir panalam?
Check the connection first. Then check the relay. If relay is stuck the outdoor starts immediately whenever you turn on your ac. Just checkout or else the relay control is gone.
Bro back bresor evlo bro
120 to 140 psi
Super bro very nice
Fridge charging step by step please sir
Please watch our channle playlist.. videos availabel
chennai laya irrukinga
No bro.. I am from trichy
Bro compressor running la gas charge pannakudadha. R410a, R32 gas mattuma illa R22 gas m vapour a dha charge pannuma
Entha gas.ah irunthalum compressor run agumbothu liqued charge pana koodathu. Compressor affect agidum.
Thanks Anna nalla tips
Safety?
Bro ac gas இல்லனா outdoor fan running ஆகுமா ஆகாதா.
Run agum. Some ac la gas illena Outdoor full.a run agathu.. Ena brand..?
@@r2_tech_tamil IFB ac
Inverter..ah..?
@@r2_tech_tamil yes
Run agum bro.. Maybe etho issue iruku. PCB or anyother
Drinking water tds level???
Less then 100 ppm
How much cost sir
3000/-
V. Good
Bro nega Chennai yaa
No. Trichy
@@r2_tech_tamil unga number send pnnuga
WhatsApp no. 9894025260
@@r2_tech_tamil tq bro
👍Super Anna 🔥
30 inches ah psl
Vaccum side called Not psi.. That's inches of Hg.
Bro ac outdoor leak test how to do it
410 கேஸ் டாப் அப் பண்ணலாமா
No..
@@r2_tech_tamil
Sir entha entha gas topup pannalam
Ethu panna koodathu detail sollunka sir
R22 matum panalam
@@r2_tech_tamil R22 gas mattum topup pannalam sir
Hi brother good jop .
Bro weight machine link vanum bro
Bro ... How much cost for charging this gas...
Its varies according to the gas bro
Super sir
Supper anna
Thank u bro
guys one request
outdoor install panna mudhu thuki sorgathila ye vechi dadhinga
its actually tough to repair
who knows whos ac is gonna be next
Please upload r32 gas bro
Upload soon
Bro same r22 gas kum ithepola compressor on pannama full wait yethitu on pannalam
Entha gas ah irunthalum ithe method follow pannalama compressor on pannama correct weight yethitu on panna pothuma
Comp on panni weight la r410,r32 gas ethuna enna aagum
Bro r22 gas weight base panni ethalama
bolt illey pa,,athu flare nut
Sorry pa flow la vanthuruchi
All videos r good.. PA
God bro
🙏🙏
Back pressure 120
Cylinder weight
Manithan vadivil Deivam Nangal
Hi ji
உங்க நம்பர் குடுங்க நண்பா டவுட் கேக்கலாமா சொல்லுவிங்களா
watch ur back step..its unsafe
R32 gas charging video
Upload soon.
Photo AC cooler problem
தல அதில் உள்ள லேபிள் இல்லை என்றால் எப்படி கணிப்பது இது ஆர் 22இது 410என்று
You can see your ac Manuel book dear.
Ungga number kuduingga anna
Anna unga num kuduga anna
Unga whatapp no sollunga
Super bro
410 gas ac la pulla vegam potu r22 ethalaamaa sir
Super bro
Super bro