STAAD.Pro Physical Models can be analyzed in the STAAD.Pro Analytical Modeler and then transferred to STAAD Advanced Concrete Design for the design of concrete beams, columns, and shear walls.
We are not aware of any timeframe as of now. But you can post this request in our Ideas forum (communities.bentley.com/products/ram-staad/i/) along with design code name. Our product management review this channel and they will add your request in future enhancement plan.
Perfect! How to apply for maritime structure like Jetty structure, please make an example in term of Jetty structure. I see every example Bentley making only in the building structure.
You can use STAAD for Offshore Jetty/platform structure analysis and design purpose. But there are certain loads like dynamic wave load which needs to be considered during analysis. For that, we have another specialized product called MOSES. You can check the sample files and videos of this product for modelling, load application and analysis of Jetty structure.
ISM is now available through iTwin services, there is no separate option available like before but the functionality is same. You can use the iTwin option in physical modeler, then use Synchronizer option to create a new ism file. Note that, Analytical Synchronizer must be installed in your system to use this module. This is a free software and normally installed during STAAD.Pro CONNECT Edition installation (unless you manually cancelled it).
When you model using physical modeler, physical objects are created (member, plate) and all property, specification, loading is assigned to physical entities. In the background, an analytical model in generated which is used for analysis. In analytical modeler, you can review the analysis model but as analytical modeler cannot handle physical objects properly, so nothing can be changed from here. Imagine you have assigned a new property from analytical modeler to a member and then again go back to physical modeler where it is not recognized. That's why editing till loading is inactive in analytical modeler and if you really want to edit, you need to detach the physical modeler using "Drop" option. I have discussed the same in the video. You can go through our structural forum for more insight and discussion -- communities.bentley.com/products/ram-staad/f/ram-staad-forum
Fantastic! Is it possible to share the macro that you had created?
communities.bentley.com/products/ram-staad/m/ram-staad-api-solutions/275215
in case you haven't found it. :)
Can we transfer physical model to staad advanced concrete for post processing
STAAD.Pro Physical Models can be analyzed in the STAAD.Pro Analytical Modeler and then transferred to STAAD Advanced Concrete Design for the design of concrete beams, columns, and shear walls.
When the other steel design codes except Australian code, will be available for physical members design??
We are not aware of any timeframe as of now. But you can post this request in our Ideas forum (communities.bentley.com/products/ram-staad/i/) along with design code name. Our product management review this channel and they will add your request in future enhancement plan.
Perfect! How to apply for maritime structure like Jetty structure, please make an example in term of Jetty structure. I see every example Bentley making only in the building structure.
You can use STAAD for Offshore Jetty/platform structure analysis and design purpose. But there are certain loads like dynamic wave load which needs to be considered during analysis. For that, we have another specialized product called MOSES. You can check the sample files and videos of this product for modelling, load application and analysis of Jetty structure.
ISM is missing in my physical modeler, there is just iTwin Services and it doesn't work, How to solve it ?
ISM is now available through iTwin services, there is no separate option available like before but the functionality is same. You can use the iTwin option in physical modeler, then use Synchronizer option to create a new ism file. Note that, Analytical Synchronizer must be installed in your system to use this module. This is a free software and normally installed during STAAD.Pro CONNECT Edition installation (unless you manually cancelled it).
If you model in physical modeling the loads will be grayed out in the analytical model, why?
When you model using physical modeler, physical objects are created (member, plate) and all property, specification, loading is assigned to physical entities. In the background, an analytical model in generated which is used for analysis. In analytical modeler, you can review the analysis model but as analytical modeler cannot handle physical objects properly, so nothing can be changed from here. Imagine you have assigned a new property from analytical modeler to a member and then again go back to physical modeler where it is not recognized. That's why editing till loading is inactive in analytical modeler and if you really want to edit, you need to detach the physical modeler using "Drop" option. I have discussed the same in the video. You can go through our structural forum for more insight and discussion -- communities.bentley.com/products/ram-staad/f/ram-staad-forum