Mitsubishi Mini Split Outdoor Control Board Install

แชร์
ฝัง
  • เผยแพร่เมื่อ 12 ก.ย. 2024
  • tandnservices.com 770-490-5595 T&N Services LLC. proudly provides HVAC services to the North Georgia area including:
    Atlanta, Canton, Woodstock, Marietta, Cumming, Alpharetta, Jasper
    For more information please visit our website @ tandnservices.com

ความคิดเห็น • 80

  • @LDriggs
    @LDriggs 16 วันที่ผ่านมา

    I know this is a older video, but it gives one of the best explanations of how each board gets its power. And what each board does. Thank You

  • @didijiji918
    @didijiji918 4 ปีที่แล้ว +4

    I got tons of knowledge from your videos, very appreciate. I have some experience to fix this type of issue, the red wire, and the white wire at the terminal board, compose of the communication lines between indoor and outdoor, they should have PWM signals when setting at DC voltage. There is an open circuit at the implanted power switch on the board, check DC voltage at the power switch and trace the PCB, you should find a component "O.L.", you may check a few resistors, diodes and a Voltage Regulator in the loop.

  • @blissJesus1
    @blissJesus1 10 ปีที่แล้ว +1

    I just installed a 2 ton Fijitsu mini-split last weekend, and was literally praying I would not have to trouble shoot it till I got done watch'n this video!

    • @TandNServices
      @TandNServices  10 ปีที่แล้ว +3

      Hey Chris, mini splits are only as hard as you make them!!!! Always remember if you get stuck on one you can always call the manufacturer, as a matter of fact they want you to call them. Thanks for watching

    • @hvactecster79
      @hvactecster79 10 ปีที่แล้ว

      T&N Services LLC. I'm calling you !! LOL.

  • @nielsbaeklund7336
    @nielsbaeklund7336 8 ปีที่แล้ว +1

    I think the problem on the board is ZD 652, there is a cold soldering you can see that the print is dark around the soldering , maybe changing zener diode and / or soldering it again
    Regards
    Niels

  • @over50txtech8
    @over50txtech8 10 ปีที่แล้ว

    Nice video Ralph, things are so much easier when you have seen them done. Keep up the good work.
    Ray

    • @TandNServices
      @TandNServices  10 ปีที่แล้ว +1

      Hey Ray I'm one of those guys that learn from watching, that's why I like TH-cam!!!! I've learned a lot from the other guys as well. Also reading peoples comments help too

  • @harrydickson4575
    @harrydickson4575 10 ปีที่แล้ว

    Great video Ralph on explaining the circuitry of the unit

  • @stevenmeltz8676
    @stevenmeltz8676 3 หลายเดือนก่อน

    This is super helpful thanks. I broke the CN3 (RT64 thermistor) wire on the power board with the capacitors on it. What's the best way to change that board out? Do I have to remove this front board first? Thank you.

  • @Straycurrent
    @Straycurrent 10 ปีที่แล้ว

    Those systems are becoming a little less intimidating, thanks to your videos. Thanks for roughing it one-handed to get the video.

    • @TandNServices
      @TandNServices  10 ปีที่แล้ว

      I really wanted to get a video on the first control board I installed but by the time I got there to do the job it was dark and I had to install it by using a flash light. I was bummed out because I didn't get to film it. So this video does prove they do break and you might come across one. Thanks for watching, I'm glad I could help

  • @davidursini4740
    @davidursini4740 ปีที่แล้ว

    I just had an hvac contractor quote me $645. labor to replace the circuit board on a Mitsubishi mini-split outdoor unit!

  • @davidwise9119
    @davidwise9119 9 ปีที่แล้ว +1

    Betcha that extra silicone blob on the new board is to keep the part from vibrating and breaking a leg due to fatigue.

  • @hvactecster79
    @hvactecster79 10 ปีที่แล้ว +1

    Nicely done and taught Ralph !! Take care, Brett

  • @billcv80
    @billcv80 ปีที่แล้ว

    Nice video/ thanks for all your current help with the big M

  • @RobHVAC
    @RobHVAC 10 ปีที่แล้ว +1

    Great video Ralph. You have some good tips there.

  • @barrypeirson3710
    @barrypeirson3710 17 ชั่วโมงที่ผ่านมา

    Doing one tomorrow.

  • @waynemiles7027
    @waynemiles7027 10 ปีที่แล้ว

    Man Ralph you are the King of mini splits! Great video! You need a laptop or ipad to troubleshoot those inverter systems don't you?

    • @TandNServices
      @TandNServices  10 ปีที่แล้ว

      Thanks Wayne, as far as needing a laptop it's not necessary, I've got a 1-800 number LOL

  • @craigoldenburg2584
    @craigoldenburg2584 8 ปีที่แล้ว +1

    nice job on Mitsubishi here in North Canada
    we get lots of power issues surges outages and I do lots of boards still customers don't want surge protectors go figure what about there?

    • @Sesamestreet9080
      @Sesamestreet9080 ปีที่แล้ว

      Just add them in your price. Customer don’t know what they want sometimes

  • @eddiehvac
    @eddiehvac 10 ปีที่แล้ว

    Ha man like the vid.. I do see these mini spits down in Florida. I wrk on them sometimes but I like the technical part. So now I no if I run in this problem I will have your video saved. Thks for the advice and the lesson.

    • @TandNServices
      @TandNServices  10 ปีที่แล้ว

      Hey Eddie it's not often you should have to work on them but when you do it's nice to get to see a video on them

  • @davidwise9119
    @davidwise9119 9 ปีที่แล้ว +1

    Those noises just after power-on were self-test. Sounded like it was poking the motors with short pulses.

  • @anthonygasparini1734
    @anthonygasparini1734 5 ปีที่แล้ว

    2 boards in one month? Wow, how much do these boards cost and what is the average labor cost to perform the repair if not covered by the warranty? Is this a common problem and if not what do you think is causing this frequent failure of the control board thank you in advance!

  • @royallan3717
    @royallan3717 8 ปีที่แล้ว +1

    Hi guys, the noises on power up are the exv( electronic expansion valves ) opening.E6 fault? He'll there are so many things that can fail, the c&n 801 pink plug should have 325- - dc .Then the fuse f64 behind the front if blow would mean the power board has failed. Near this fuse are white resistors 10 ohms 5w . Make sure you check them and again the left power board would fail these.On the power board with three blue caps- red probe to n and black to p(yes) power off there should be hi resistance in k ohms and between u v w, not low ohms.Check those exv ,s are not corroded on valve stems- it will blow out resistors where they plug in.If a exv fails and no spares 2 curved magnets will open it turned like a tap. C/w shut and cc/w openHope I've helped somebody .Roy in nz

    • @jtveg
      @jtveg 7 ปีที่แล้ว

      So why exactly would the corrosion on the exp valve cause it to blow the resistors.
      Are these resistors controlling the exp valves or is the valve remaining shut and causing high pressure on the compressor and therefore overloading the drive circuitry that the resistors are part of?
      Very curious thanks.

    • @philippemartin1885
      @philippemartin1885 7 ปีที่แล้ว

      John Thimakis

    • @jtveg
      @jtveg 7 ปีที่แล้ว

      Philippe Martin​
      Yes sir. You mentioned me.
      What is it ? 🤔

  • @user-ln7of9gs4s
    @user-ln7of9gs4s 2 ปีที่แล้ว

    What causes the boards to fail? Can the consumer to anything to prevent failure?

  • @danielzamora3625
    @danielzamora3625 10 ปีที่แล้ว

    great video Ralph on these mini split thanks for posting

  • @10rninjariderzx
    @10rninjariderzx 9 ปีที่แล้ว

    I have two 2 ton mr slims with bad boards. thank you so much

  • @HVACShopTalk
    @HVACShopTalk 10 ปีที่แล้ว

    Nice work I learned a lot. Thanks Ralph

  • @Imwright720
    @Imwright720 3 ปีที่แล้ว

    Actually I saw several spots that seems burned. You did it so fast but it looked like a little capacitor was burned.

  • @nicholasrowan2768
    @nicholasrowan2768 10 ปีที่แล้ว

    Nice video Ralph and most definitely learned a lot

  • @jhhvacplumbing1944
    @jhhvacplumbing1944 10 ปีที่แล้ว

    Good video Ralph , thanks for the info and explain.

  • @leek163
    @leek163 10 ปีที่แล้ว

    Nice video. I am actually going to the mitsubishi m & p class near atlanta in septemeber.

    • @TandNServices
      @TandNServices  10 ปีที่แล้ว

      you will die when you see how big the building is. I've got a video on the building, I was driving by it one day. I might check on going to the M&P class myself as a refresher as a diamond contractor they give us one class a year for free.

  • @waynehensley9277
    @waynehensley9277 10 ปีที่แล้ว

    thanks for the info Ralph it's really helpful

  • @Gohjunyi88
    @Gohjunyi88 4 ปีที่แล้ว

    why does the AC control board damaged so easily, is it due to surge?

  • @JamesPettinato
    @JamesPettinato 10 ปีที่แล้ว +6

    I so do not like circuit boards. They're always way too expensive. The companies go out of business or the company changes to a different board or stops making that board or every electric issue causes a problem and you can't get anywhere with the utility company or you have to call a 1-800 number for technical assistance and after an hour of fustration talking to some guy in india decifering his english you get nowhere. Why do you need them. I've come across older AC systems on restaurants that have obsolete circuit boards, I removed them and installed a compressor contactor, a blower contactor a time delay a 24v transformer and a new thermostat...easy...strong and works long term like a refrigeration system and I didn't have to take a $1500.00 course to work on the units circuit boards. Sorry for the rant, I drank too much coffee, I have to go fix a bakery freezer. (no circuit board) My glycemic level goes up just smelling the confectionary sugar there, it's a sweet job.

    • @theAppleWizz
      @theAppleWizz 5 ปีที่แล้ว

      because if you want high efficiency it's needed.

  • @rcj509
    @rcj509 10 ปีที่แล้ว

    T&N Services LLC. Ralph do you know if Mitsubishi makes a unit that can handle the cold up my way? I know we're installing a mini-split heat pump in a enclosed porch but I think it's a Fuji.

    • @TandNServices
      @TandNServices  10 ปีที่แล้ว

      Hey Rob, They do make one, I would go talk to the supplier or give the applications department at Mitsubishi a call to see which one the suggest

  • @OldAcres8690
    @OldAcres8690 8 ปีที่แล้ว

    Are multi zoned mini split are a good alternative to a regular central unit?

  • @agostinhomartins8373
    @agostinhomartins8373 5 ปีที่แล้ว

    I accidentally wired the active cable for my main power in to a signal terminal where the sdi cable goes. Is there a high chance I would've blown the board? My ac split system runs but it doesn't cool..it's pretty much a fan lol

  • @woodenboatclassroom7172
    @woodenboatclassroom7172 6 ปีที่แล้ว

    Can you help me, my 18 k is ok but the two 9k are not communicating with the out door unit I can turn them on with the remote the luvers open and the fan comes on. What is the most likely cause on the pproblem?
    cheers Walter

  • @hvacman77
    @hvacman77 10 ปีที่แล้ว

    Thanks for the lesson

  • @robertmencl9169
    @robertmencl9169 7 ปีที่แล้ว

    hi what state are you in? looking for good service in Baytown, tx.
    do you know a good supplier for boards for Quietside? Thanks, robert

  • @spiderstone
    @spiderstone 7 ปีที่แล้ว

    Is it hard to change an expansion valve?

  • @stanislavzhelkovskii217
    @stanislavzhelkovskii217 5 ปีที่แล้ว

    Hey Ralph, where can I buy this circuit board? Thanks in advance

  • @woodenboatclassroom7172
    @woodenboatclassroom7172 6 ปีที่แล้ว

    Can you help me, I have a Friedrich model # MR36TQY3F ser# ABFT 02178 for 5yrs. working ok but now the 18

  • @LmTeamWaxOffroad
    @LmTeamWaxOffroad 10 ปีที่แล้ว

    Good video!

  • @jimbola77
    @jimbola77 8 ปีที่แล้ว

    nice job!!!!

  • @perryfree3903
    @perryfree3903 16 วันที่ผ่านมา

    😂😂 I found out the hard way one day when my hands was damp why you don't play with that pink molex plug cuz I took that DC voltage to my hand ouch

  • @bobbydigital8
    @bobbydigital8 6 ปีที่แล้ว

    Anybody seen video on the board on top of the unit?

  • @royallan3717
    @royallan3717 8 ปีที่แล้ว

    Hi t&n , check those expansion valve and stems for corrosion. Swap unused for the two circuits in use. Just a thought after you replacing the board more than once.(:

    • @tonytung6494
      @tonytung6494 2 ปีที่แล้ว

      what did you mean by swap unused for the 2 circuits in use? Where is the expansion valve and stem in the outdoor unit?

    • @royallan3717
      @royallan3717 2 ปีที่แล้ว

      Hi, I mean if you thought electronic expansion valves were,t opening on power up and may be or giving problems you could use spare un used from indoor circuit d. Swap the head and plug. They are at the bottom back.

  • @spiderstone
    @spiderstone 7 ปีที่แล้ว

    My liters on the circuit board are flashing 3 flashes

  • @JamesPettinato
    @JamesPettinato 10 ปีที่แล้ว

    If I was King for a day I'd outlaw circuit boards, and louvers on AC condensers, and gold toothed sun tanned golf sweater wearing maintence contract salesmen who take your customers on Jan 1 when you need them the most, after taking care of them all summer.

    • @TandNServices
      @TandNServices  10 ปีที่แล้ว

      Jim your in a roll today!!!! I don't know who ruffled your feathers but I like your comments this fine Friday morning

  • @deanperry915
    @deanperry915 5 ปีที่แล้ว

    More than likely a sensor issue not the board if the sensor resistance isn't correct there will be a lock out relay activated on the board

    • @reneparon7105
      @reneparon7105 5 ปีที่แล้ว

      Dean Perry can the lock out be reset? Cheers

    • @deanperry915
      @deanperry915 5 ปีที่แล้ว

      @@reneparon7105 yes by replacing the sensor or sensors with the correct resistance reading for that model problem solved

    • @SnickasBah
      @SnickasBah 4 ปีที่แล้ว

      But the new board got it running not a sensor.

  • @jtveg
    @jtveg 7 ปีที่แล้ว

    Thanks for the info. 👍

  • @jeffxhaosis6784
    @jeffxhaosis6784 10 ปีที่แล้ว

    this shit would be allot simpler if we listened to TESLA.... LOL Chasing electricity seems to be our biggest job, or mopping water up...

  • @purplemonster2239
    @purplemonster2239 4 ปีที่แล้ว

    Customer is lucky it's the control board and not the power board. That big ass power board is expensive as F@#k.