How to check Vaccum Interrupter of Vaccum Circuit Breaker | VCB Breaker | Electrical Practical Video
ฝัง
- เผยแพร่เมื่อ 3 ม.ค. 2022
- Get the BEST PRICE at IndiaMART
Vacuum Interrupters: dir.indiamart.com/impcat/vacu...
Vacuum Circuit Breaker Panel: dir.indiamart.com/impcat/vacu...
Electrical Testing Service: dir.indiamart.com/impcat/elec...
#vaccumcircuitbreaker
#vaccuminterrupter
#vaccumbottle
#vcb
#circuitbreaker
#breaker
#electrical
In this video you will know about HOW TO CHECK VACUUM INTERRUPTER OF VACUUM CIRCUIT BREAKER @BOLBULBULIndustrialElectrical
Electrical safety is very important. में निम्नलिखित सामान का उपयोग करता हूँ ।
1. Safety shoes :amzn.to/3XCcRe0
2. Safety helmet :amzn.to/3raCWF1
3. Safety glove HT : amzn.to/433vM2N
4. Cut Proof stab resistance glove : amzn.to/3NHMhfk
5. Safety goggles : amzn.to/3raxodG
6. Dishcharge earthing rod : amzn.to/44es4EY
7. High voltage detector : amzn.to/43ahMUW
8. Face shield with helmet : amzn.to/46zEuIQ
9. Ear plug : amzn.to/3r8HCv8
10. LoTo tags : www.amazon.in/dp/B07M8SF6QK/r...
***********************************************
I use these instruments during troubleshooting
1. Digital Multimeter:amzn.to/3PFtF2a
2.5 KV insulation tester :amzn.to/3NDmWTL
3. Miliamps clampmeter :amzn.to/3XBymfc
3. 2.5 KV insulation Tester : amzn.to/3rcahzu
4.Digital multimeter with clampmeter :amzn.to/3NUsY3E
5.Digital multimeter with infrared thermometer: amzn.to/3NUsY3E
6. 1 KV insulation Tester : amzn.to/44aLV7O
***********************************************
I use these tools during maintenance work
1.tester : www.amazon.in/dp/B07DD1CRRL/r...
2. Screw driver set
www.amazon.in/dp/B00JLJ9IDQ/r....
3.socketset : amzn.to/46xdWrB
4.ring spanner set :amzn.to/3JKIcph
5. DE spanner set : amzn.to/3CUdk1V
6. Allen Key set : amzn.to/43aeVvc
7. Wire Crimping tool kit :amzn.to/3ptEv0p
8. Wire terminals crimping tool kit : amzn.to/3PzJFm8
9. Plier set : amzn.to/449cFWn
10.Air blower : amzn.to/3PzMN1m
11.CRC cleaner : amzn.to/3PzN2JO
You can also watch my other electrical topic related videos.I have more than 18 year of Working experience in electrical field.
Field of experience in maintenance and troubleshooting in various equipments like
1. ESP ( Electrostatic precipitator)
2. VFD ( Variable Frequency Drives) upto 1850 KW
3. Switchgear upto 11 KV
4. PLC (Programmable Logic Control )
5. LT & HT motor
6. Transformer upto 5 MVA
7. BMS ( Burner Management System )
8. Overhead EOT crane and hoist
9. Belt conveyor system
10.Crusher
11. Stacker & Reclaimer
#electricalpanel #electricalvideo #electricalvideos #electricaldrawing #electricalfault #motor #cable #circuitbreaker #esp #vfd #electrostaticprecipitator #industrialelectrical #skilledhindustan
contact details :
email : omishasamal@gmail.com
mob no : 8249341942
Get the BEST PRICE at IndiaMART
Vacuum Interrupters: dir.indiamart.com/impcat/vacuum-interrupters.html?YT7&YTI
Vacuum Circuit Breaker Panel: dir.indiamart.com/impcat/vacuum-circuit-breaker-panel.html?YT7_1&YTI
Electrical Testing Service: dir.indiamart.com/impcat/electrical-testing-service.html?YT7_2&YTI
Best explanation video for VCB maintenance 🙏
Thank you
Good job
Thank you
Good attitude
Thank you
Very nice n informative video !
Thank you
Thank you sir
You are Wel come.
Nice 👍👍👍
Thank you
Thanks 🙏🙏
Welcome
Very informative video thanks for information
Thank you
Very informative video 🙏🙏🙏🙏
Thank you
Outdoor vcb 36 kv ka v video baniye pls sit
pls sir HT panel areva ka Drawing dekhana sikhaye( par video banaye)
Thik hai drawing ko lekar ek series banayenge. Video dekhte rahie.
Excellent
Thank you
thanks again sir
Welcome.
True
Sir namaskar sir aap intrapte botal ko check kara hi ye instrument kha miley ga. Please help me
Nice
Thank you
how are do Vaccum bottles lekege 💐
Sir 1 week pahle 10mva transformer ka oil down kr k oltc chamber ka gasket change hua tha, kaam hone k baad oil filter kr k daala gaya aur 3 drum new oil dala gaya, uske baad se kvi kvi 3 hr 7hr 6hrs k baad baad bucozl relay aram aa jata hai, fr hmlog b. Relay realse kr k reset kr dete hai but after few hrs fr se aata hai aisa q sir kya solution hoga pls reply!?
what is Erosion Indicator in vcb?? what's the standard value ? can u explain brother?????
For different type , its value is different. Due to erosion and mechanical deformation (compression) of the contacts, the
contact stroke increases and the contact force is reduced.
Sir please told me 💐 vaccum bottles work 💐
Contact close open bottle ke andar hota hai. Bottle vaccum hota hai nahi to HF6 gas fill hota hai.
Hii sir vacum pressure kitna hona chahiy
Sir fix and moving contact me arc kab generate hota close ya open condition me
Open hone ka time pe.
Thank you sir
You are welcome
tool ka naam kitna hai. or ac high voltage kitna dete hai or kitne time ke liye
Please explain how are do closing opening coil cheqe before proceeding 💐
' circuit breaker ' playlist check kare. Video mil jayega.
Sir *High voltage kaise apply karenge breaker par vacuum pressure check karne ke liye kya teeno phase par high voltage apply karna hai ek saath aur high voltage kit se resultant breakdown voltage kitni aayegi•••••• kya yeh operation breaker ko open position par rakhkar karna hai*
Open condition . High voltage test should be carried out by testing section.
How much pressure inside vaccum bottle sir
Detail available in Video.
20000 operations 1 per dat 54 years
Yes
. 01mm Hg is pressure
Ok
Sir vacuum bottle me kitna vacuum pressure hota hai...
10^-6 torr
Sir presure kitna hona chahiye 💐
Video me mention hai
Sir there is no point of measuring Vacuum pressure in the Vacuum Interrupter in the VCBs. First of all know the theory well and then come to the media to teach others. If there is 0.00001% loop leak in the Vacuum Interrupter, the total Unit will fail to be healthy. Its gone. There ia option rather than replacing it with new one
how can we know if it leaks ?
@@BOLBULBULIndustrialElectrical Boss there's no logic in your question. Think deep into the theory of Vaccum technology. Nobody can lay any pressure in the vacuum tube and set a parameter for the same. Its an infinite term. Once the vacuum is lost even a measure of 0.00001% it is become inefficient or unworth to interrupt the power electrifies through it. Anybody say anything. Don't come here for knowledge. Read the books and and grow in technical knowledge. Go to the Siemens technical gallery available in the websites
But question is How can we know vaccum interrupter is correct or defect & when to replace ?
@@BOLBULBULIndustrialElectrical its easy Sir. Even non technical can detect it. When you apply the minimum primary voltage through pole to pole from any insulation tester or ipod device, it will show some mega ohmic value or show short, even while the breaker is open. It will show the value, even if there be very very nano level puncture in the Bottle and become unfit for high voltage Interruption. When you insert the VCB with punctured VI into the panel, you will expect the handed flash over or blasting
Same thing I try to explain in this video. In Industrial work it is important how quickly you sort out the problem. In Industry there are many electrical equipments .No one could not be expertised in all section. So I try to upload practical videos , which could help someone in Industry.
Thank you Sir
👍