Boss mere pass nitrox 6kw hai kia main aik string main 6 pannels 575w ky ur 2nd string main 7 pannel laga sakta hun 575w ky ? .? Because mera nitrox 6kw solar pv 7800 max supported hai ? Kindly guide
@@AGradeSolarKarachi mein situation clear krta k huwa kya hai. Kl rat 1 bjy main breaker trip ho gya r sara load battery py shift ho gya. Phir subah 4 35 py pump on kia to inverter output 0 ho gyi. Wapda off thi. Phir mein ny wapda on ki r connect hony ka wait kia. Jb connect ho gyi phir pump on kia to phir st inv output 0 r hr dfa F56 fault. Phir mein grid charge on kia r battery charge krwayi 28% tk. Phir pump on kia to load wapda sy share hua sai sy. But kuch time bd again pump on kia to wapda disconnected r load batteries py. Pump bnd kia to wapda connected. R 2nd question k sari rat batteries use to system bnd kun ni hua 40% battery pr. Full drain kun hoyin batteries. Thanks please iska solution btaye ga.
Bhai battery ka jawab m deskta percentage pr jab ap rkhen gen to kbhi bhi apko full discharge nh milegi islie ap usko voltages pr rkhen to. Apko 80% pr backup den gin
Boss mere pass nitrox 6kw hai kia main aik string main 6 pannels 575w ky ur 2nd string main 7 pannel laga sakta hun 575w ky ? .? Because mera nitrox 6kw solar pv 7800 max supported hai
? Kindly guide
Yes U Can Attach Easily
Sir apne jo smart load ko automatic karne e ke liye contactor konsa use kiya he uski details and wiring share kar dain kese ki he
for how much load this system is installed?
Netmetring ho jy gi is pe ?
Mera nitroxe 3kw grid ko feed krta hai aur excess electricity reverse krta ha meter ma.Any solution for this probelm?
If Programing is Ok Then Contact Inverex Senior Support for Upgrading it's Firmware Software
Sir CT q nai lagani chahiye agr lgaien to kia problem ati hy?
Or kindly DRM switch ka function btaien plz.
Ct na lagayain it will cause issue in current series and drm switch is sensor for starting inverter
Sr matrix inverter ki gen port pe genrater use kren to jb wapda in hogi to kese behave krega inverter ?
System Ki auto priority Wapda ya KE Hoti Hai - Yeh Generator ko chor dega
@@AGradeSolarKarachi g BHT shukrya Apka
@@AGradeSolarKarachi Allah Pak apki Rizq mal Jan me Barkat Dale km hi log dekhe jo apki trh professional hon or am dekhne wale ko reply kren
Walakum AL Salam rahmat ala
ارسلان بھائی نائٹروکس 3kw کے ساتھ 2عدد انوریکس لیتھیئم پاور وال 24v پیرالل کر کے لگا سکتے ہیں یا نہیں ؟؟؟؟
DRM ke cable kis port mein lgani hoti hy?
DRM Port - the last and most bottom port in inverter
Nitrox inverter py jb load solar capacity sy zyada ho to wapda off ho jati hai. What could be the issue?
Never Seen Such Issue - Ager Bohat Zeda Over Load Kerian Ge to EASA Hei Hoga - Verna Extra load Wapda ya KE se Share Hota Hai
@@AGradeSolarKarachi mein situation clear krta k huwa kya hai.
Kl rat 1 bjy main breaker trip ho gya r sara load battery py shift ho gya.
Phir subah 4 35 py pump on kia to inverter output 0 ho gyi. Wapda off thi. Phir mein ny wapda on ki r connect hony ka wait kia. Jb connect ho gyi phir pump on kia to phir st inv output 0 r hr dfa F56 fault. Phir mein grid charge on kia r battery charge krwayi 28% tk. Phir pump on kia to load wapda sy share hua sai sy. But kuch time bd again pump on kia to wapda disconnected r load batteries py. Pump bnd kia to wapda connected.
R 2nd question k sari rat batteries use to system bnd kun ni hua 40% battery pr. Full drain kun hoyin batteries.
Thanks please iska solution btaye ga.
Bhai battery ka jawab m deskta percentage pr jab ap rkhen gen to kbhi bhi apko full discharge nh milegi islie ap usko voltages pr rkhen to. Apko 80% pr backup den gin
@@muhibshaikh4511 voltage pr hi hai bhai. R 4.5 hr k bd bhi shutdown kun ni hua system
Wapda le ga ya gnrTer use krega any isue
Generator Ki Port Seperate Hai and Wapda Ki Port Seperate - Ager Generator Ke On Hone Per Wapda Aa Jati Hai to Load Wapda Per Convert Ho Jaye Ga
Sir yeh lithium batteries kia poori raat ac chalayegi ?
😄😁🤣 Bahi 2.5KW Battery Hai Uska Bhi 90% Aypko Mile Ga 500W for 4 to 4.5 Hours
بھائی جان نائٹروکس 3kw کے ساتھ انوریکس لیتھیئم پاور وال 24v پیرالل کر کے لگا سکتے ہیں یا نہیں ؟؟؟؟@@AGradeSolarKarachi
3kw system install krwana hai malir saudabad k area may
WhatsApp 03433477786
Aoa
Sir is 3 kw system ki breakable cost share kejyega
☑️ Check Description of Video
Sir nitrox battery specifications ?
Drm function..?
Its kind of sensor
Thanks
Hyderabad mein aap service provide karte hain kindly share contact number..
@@khurrammughal4954 Jee Installation Available in Hyderabad WhattsApp On 03433477786
How we contact you.i live in karachi
WhattsApp 03433477786 in Working Hours
❤❤
Nitrox 8kw price?
485 - 500 Depend upon Availability
No SOH informatiom
SOH ???
@@AGradeSolarKarachi SOH means State Of Health
CT aur temperature sensor kiun nahi lagana?
@@sarzameen4051 temp sensor is for liquid battery . Where as bms already contains that information . CT is for selling purpose
Total cost of this project
Sir Check Description of Video