I really think you have a TXV problem 34 degree superheat and 9degree subcooling. That superheat is twice what it should be. Could it be none condensables, possible but I think I would have taken a close look at TXV. New TXV new dryer pull good vacuum new gas problem solved. Good job. I’m new to your channel I’ll be back
Popped up on my recommended tab, subscriber of hvac videos, very pleased to see another TH-camr making great content!
your channels gonna take off man. great videos!!!
@@megadevin09 thank you.
I really think you have a TXV problem 34 degree superheat and 9degree subcooling. That superheat is twice what it should be. Could it be none condensables, possible but I think I would have taken a close look at TXV. New TXV new dryer pull good vacuum new gas problem solved. Good job. I’m new to your channel I’ll be back