Houdini: Control Smoke by Max Density

แชร์
ฝัง
  • เผยแพร่เมื่อ 11 ต.ค. 2024
  • I'm retreiving the absolute max density by using "Gas Reduce"-Node + "Modify Data"-Node and use this value to control the smoke turbulence (via control field).

ความคิดเห็น • 14

  • @vitalyantonovas321
    @vitalyantonovas321 3 ปีที่แล้ว +6

    Hi Simon! Great tutorial ! about Geometry spreadsheet: you need turn off all attributes and turn on only desired attribute and then it will be arranging by max\min much proper. And second observation: when you had been getting max value from Dopimportfield and added Volumeslice you could turn on a switcher on Dopimportfile ->Compute Min\Max value and get the values instantly. By default it is off. Sorry if I look like nerdy))

    • @HoudiniSimon
      @HoudiniSimon  3 ปีที่แล้ว

      oh thank you! awesome tips!

    • @beardirty6081
      @beardirty6081 2 ปีที่แล้ว

      @@HoudiniSimon Sorry, I don't understand why use modify data? Why not use max directly? And it (gas reduce) reflects the maximum in real time.

  • @everydayhero3610
    @everydayhero3610 4 ปีที่แล้ว +1

    Oh, I haven't heard about dropping attributes directly from the spreadsheet. I have a strong feeling that that's gonna save me a couple of headaches at some point. Thank you for sharing your knowledge with us!

  • @christianbohm6118
    @christianbohm6118 3 ปีที่แล้ว

    Where was this video all those years when I needed it? Oh, it's only here for a few months...I see. Thanks, Simon! Super helpful!

  • @OscarGaya
    @OscarGaya 4 ปีที่แล้ว

    Intersting workflow, Thanks Simon

  • @kae-jg
    @kae-jg 3 ปีที่แล้ว

    Hey Simon, thanks for the very useful video !
    Kinda late now, so you probably figured it out but about 14:22 it's just one of houdini display issues, you just have to sort another attribute (like Cd, whatever) and sort again your density, it will be correclty sorted. :)

  • @i20010
    @i20010 ปีที่แล้ว

    Thank you for a very good tutorial! So what is the Binding tab in the Turbulence? Isn't that also controlling the amount, like the Control tab? What is the difference between those? Thank you!

  • @supermegavfx4270
    @supermegavfx4270 3 ปีที่แล้ว

    Thank u Simon)

  • @viki164
    @viki164 3 ปีที่แล้ว +1

    I thought the control field remapping normalizes the density mapping ( if you see inside Gas Turbulence node there is a fit range node inside "if control field") so one doesn't need to feed in min and max values ?

    • @HoudiniSimon
      @HoudiniSimon  3 ปีที่แล้ว +1

      Need to check this. Thanks for the hint!

  • @philippaps44
    @philippaps44 ปีที่แล้ว

    very helpful! thanks! one question about the gas reduce, its used just to output data from the sim but has no other effect on the actual sim?

  • @briyaniisnice9380
    @briyaniisnice9380 2 ปีที่แล้ว

    Hi why do you use modify data ?