Testing Water Hardness with HANNA HI 3812 Hardness Test Kit | Drinking water test

แชร์
ฝัง
  • เผยแพร่เมื่อ 24 พ.ย. 2021
  • Water hardness is an important factor to consider when it comes to water quality. The HANNA HI 3812 Hardness Test Kit is a reliable and accurate way to test for water hardness in both residential and commercial settings. This kit is easy to use and provides quick results, allowing you to make informed decisions about water treatment options. In this article, we will walk you through the process of testing water hardness using the HANNA HI 3812 Hardness Test Kit, as well as provide tips for interpreting your results and potential treatment options
    Here used HI 3812 Hardness Test Kit
    HIGH RANGE - 0 to 300 mg/L CaCO3
    • Remove the cap from the small plastic
    vessel. Rinse the plastic vessel with
    the water sample, fill to the 5 mL
    mark and replace the cap.
    • Add 5 drops of Hardness Buffer through the cap port
    and mix carefully swirling the vessel in tight circles.
    • Add 1 drop of Calmagite Indicator through the cap port
    and mix as described above. The solution becomes a redviolet
    color.
    • Take the titration syringe and
    push the plunger completely into
    the syringe. Insert tip into HI
    3812-0 EDTA Solution and pull
    the plunger out until the lower
    edge of the seal is on the 0 mL
    mark of the syringe.
    • Place the syringe tip into the
    cap port of the plastic vessel
    and slowly add the titration
    solution dropwise, swirling to
    mix after each drop.
    Continue adding the titration solution
    until the solution becomes purple, then
    mix for 15 seconds after each additional
    drop until the solution turns blue.
    • Read off the milliliters of titration solution from the syringe
    scale and multiply by 300 to obtain mg/L (ppm) CaCO3.
    LOW RANGE - 0 to 30 mg/L CaCO3
    If result is lower than 30 mg/L, the precision of the test can
    be improved by following the procedure below.
    • Remove the cap from the large
    plastic vessel. Rinse it with the
    water sample, fill to the 50 mL
    mark and replace the cap.
    • Proceed with the titration as for the high range test.
    • Read off the milliliters of titration solution from the syringe
    scale and multiply by 30 to obtain mg/L (ppm) CaCO3.
    Range 0 to 30 mg/L (ppm) CaCO3
    0 to 300 mg/L (ppm) CaCO3
    Smallest Increment 0.3 mg/L [in the 0-30 mg/L range]
    3 mg/L [in the 0-300 mg/L range]
    Analysis Method EDTA titration
    Sample Size 5 mL and 50 mL (average)
    Number of Tests 100 (average)
    Case Dimensions 200x120x60 mm (7.9x4.7x2.4")
    Shipping Weight 460 g (1 lb.)
    Video Link 👇👇
    1. • Vacuum filler machine ...
    2. • Canon Image Runner 252...
    3. • Importance of Earthing...
    4. • Efficient Cattle Slaug...
    5. • Optimizing Meat Indust...
    6. • 11KV Substation ,Subst...
    7. • Meat and Livestock ani...
    8. • Guide to Checking PFI ...
    Cover Topic In This Videos :-
    #Watertest #Hardness #Drinkingwater
    🔴 Disclaimer :- Some contents are used for educational purpose under fair use. Copyright Disclaimer Under Section 107 of the Copyright Act 1976, allowance is made for "fair use" for purposes such as criticism, comment, news reporting, teaching, scholarship, and research. Fair use is a use permitted by copyright statute that might otherwise be infringing. Non-profit, educational or personal use tips the balance in favor of fair use. All credit for copyright materiel used in video goes to respected owner.
    Sources :
    www.google.com
    www.wikipedia.org/
    Music by ZakharValaha from Pixabay
    Me & You by MusicbyAden | / musicbyaden
    Music promoted by www.chosic.com/free-music/all/
    Creative Commons CC BY-SA 3.0
    creativecommons.org/licenses/...
    For Business Enquiry Email :- zutubetele@gmail.com
    For Subscriber Any Problem :-massage us on facbook
    👆 Don’t Forget To Like , Comment , Share & Subscribers
    [ THANKS FOR WATCHING THIS VIDEO ]
    Order Any Industrial Equipment : www.immenso.com.bd
    Facebook page : immenso.com.bd
    ▶️Facebook - : HuntingTheCreativity
    Immenso.com.bd
    / immenso.com.bd
    / immensobd
    Website :immenso.com.bd/free-learning-hub
    / huntingthecreativity
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 9

  • @michaelespinosa3099
    @michaelespinosa3099 ปีที่แล้ว

    🎉wow great job 👍 9ppm is zero hardnes how regenerate Water softener

    • @HuntingThecreativity
      @HuntingThecreativity  5 หลายเดือนก่อน

      Water softner regenerate by Salt. You can check our RO water video for more details.

  • @michaelespinosa3099
    @michaelespinosa3099 ปีที่แล้ว +1

    Tips how menutes renegeretion Water softener ❤

  • @shahinooralam3435
    @shahinooralam3435 ปีที่แล้ว +1

    Colour change হবার আর অতিরিক্ত সলিউশন এড করার দরকার ছিল কি?
    কারন ওই সলিউশনের পরিমান টাই মূলত টোটাল হার্ডনেস নির্দেশ করবে।
    যা ৩০ বা ৩০০ দিয়ে মাল্টিপ্লাই করতে হবে।

    • @HuntingThecreativity
      @HuntingThecreativity  5 หลายเดือนก่อน

      জি একদম ঠিক বলেছেন। কনফিউশানের জন্য এটা আরো এড করা হয়েছে যেন বিষয় টি আরো পরিস্কার হয়।

  • @horkumarroy645
    @horkumarroy645 2 ปีที่แล้ว +1

    হার্ডনেশ রেঞ্জ কত