Ups ko stabilizer ki tarah upyog me la sakte hai kya Yani ki ups me battery na use karke keval pc ko 240 voltage maintain rakhna hai power kam ya jyada hone par pc me koi problem bhi na aaye
sir v gaurd ups of same model is there having low volttage 170 ac when ac commercial sw off new battery of 13.4 v dc battery is replaced please advise which component is suspectable please advise above 200 volt ac is required please advise
By the way, on most cheap multimeters, the voltage of UPS output is 160-170V, when there is no mains power. This is because, cheap UPS is made using square wave switching but cheap multimeter cannot calculate square wave properly.
I have V guard slender 600. UPS board charging volts only 10.5volts. So battery not charging properly. It requires over 14votls to charge the battery. Battery is now one. What can be the problems ?
Ups ko stabilizer ki tarah upyog me la sakte hai kya
Yani ki ups me battery na use karke keval pc ko 240 voltage maintain rakhna hai power kam ya jyada hone par pc me koi problem bhi na aaye
Yes you can use if your ups support to give power supply without battery.
I have similar problem in UPS, but where can I get the PCB? Is it available in amazon?
Sir you can get it from the company service centre
Sir ji you can get it from the company service centre.
बहुत अच्छा वीडियो हैं,
Sir,
मेरे ups में जो स्पीकर के पास 3 टांगो का काला हैं वो फट गया उसका नंबर बता देंगे
🙏🙏
Thanks for your valuable comment Sir ji, if i get same ups board then definitely🙂 inform you.
Very nice video, big like..
Thanks for your valuable comment sir ji 🙂
Sir mene battery point ulta lga diya ha ab on nmho rha h par on hoke band ho jata hai
Help
Sir ji don't experiment with ac voltage ⚡.
For more details please check my computer Hardware playlist 🙏
aap ka vdo acha laga sir ji mera zebronics ka hai lekin dead hai muje pcb board chaiye mil sakta hai?
Sir ji service centre me search kijiye 🙏
Ek 600va/360w ki ups me kitne amp tak ki battery laga sakte hain? Please repley.....
Sir ji it depends on UPS, you have to follow the configuration.
@@itkoustav computer ki ups 2000-2500rs ka.
sir v gaurd ups of same model is there having low volttage 170 ac when ac commercial sw off new battery of 13.4 v dc battery is replaced please advise which component is suspectable please advise above 200 volt ac is required please advise
App ka agar current low voltage hai then use voltage stabilizer
And agar app ka ups se low voltage AA Raha he then then check ups transformer
By the way, on most cheap multimeters, the voltage of UPS output is 160-170V, when there is no mains power.
This is because, cheap UPS is made using square wave switching but cheap multimeter cannot calculate square wave properly.
I have V guard slender 600. UPS board charging volts only 10.5volts. So battery not charging properly. It requires over 14votls to charge the battery. Battery is now one. What can be the problems ?
Sir ji transformer check kijiye 🙏
Bord ka price
Sir ji online check kijiye 🙏
Mera pass same board hai
Isme ek problem hai wo low cut battery hoke ups off ho ja raha hai
Please help me
How to remove low battery cut off problem
Sir ji Transfer check kijiye 🙏
@@itkoustav sab kuch okey hai 10.5 v per cut off ho Raha hai battery low protection may ja raha hai
क्या पीसीबी 1000 केवीए यूपीएस ट्रांसफार्मर में लगेगा
sir ji if it's 1kva then you can
मॉसफेट भी सही हो रिले भी सही हो सब कुछ सही हो लेकिन ऑन होते ऑफ हो जाता है क्या प्रॉब्लम हो सकता है
sir ji it's happen when you are using 600va ups and you have RGB cabinet or graphics card
@@itkoustav yes sir i have rgb cebinet why i have garphics but i am not using but still the same comes
New bord kaha milega
Yes you can contact service centre
@@itkoustav online nahi mil sakta hai
Sir ji please contact authorised Service Centre
Board mil jayega kya UPS ka🎉🎉🎉🎉
Sir ji please visit your nearest service centre 🙏
Board milega
क्या पीसीबी 1000 केवीए यूपीएस ट्रांसफार्मर में लगेगा
sir ji if it's 1kva then you can