Why tester glow both side in socket || in Urdu/Hindi || Easy Skill

แชร์
ฝัง
  • เผยแพร่เมื่อ 27 ส.ค. 2024
  • Hi friends
    I am Mazhar Iqbal welcome to our TH-cam channel Easy Skill
    In today's video, we will learn about the electric screwdriver which is also commonly called a tester. Sometimes when we try to check electricity with the help of this tester on an electric board etc. This tester is light up at both points of the sockets and we think that current is flowing in the socket, but why is no appliance in it is working. So we will know in detail why this happens and what is the logic behind this when the tester should light up at only one point
    If you found this video useful then please like and share it with others
    And if you are new to the channel subscribe to get more useful videos
    Thanks for watching
    Mazhar Iqbal
    Easy Skill
    How to make electric board: • How to make an electri...
    Queries Solved
    1- Why tester glow both side in socket
    2- how to use electric tester
    3- why phase comes both side in socket
    4- socket main tester donon taraf q jalta hai
    Join our Social Media Links :
    Facebook Page: www.facebook.c...
    Twitter: Ma...
    Instagram: / mazhareasyskill
    OTHER PLAYLISTS
    Electronics Repairing: • Electronics repairing
    New Electronic Projects: • New Electronics Projects
    Electronic components: • Electronic Components
    Physics: • Electronics repairing
    Electrical: • Electrical
    Computer: • Computer
    #Tester #LightTesterUse #Electricity #EasySkill

ความคิดเห็น • 228

  • @noorhiba
    @noorhiba ปีที่แล้ว +33

    تمام جہانوں کی جان _حضرت محمد۔۔ پر کروڑوں درود۔ و سلام __"__💞💞💞__"__

  • @user-tx6tn8wo6k
    @user-tx6tn8wo6k ปีที่แล้ว +3

    ماشاءاللہ بہت اچھے طریقے سے بتاتے ہیں جس پتہ ہو پھر بھی آپ کی ویڈیوز دیکھتے ہیں

    • @user-tx6tn8wo6k
      @user-tx6tn8wo6k ปีที่แล้ว

      جس کا پتہ ہوتا ہیں پھر بھی آپکی ویڈیو تقریبن دیکھتے ہیں ماشاءاللہ زبردست اللہ تعالی اپنی رخمتوں کے سائے میں رکھے دونوں جہاں کی برکتوں سے خوشیوں سے ملا مال کرے آمین

    • @EasySkill
      @EasySkill  ปีที่แล้ว

      بہت شکریہ پیارے بھائی آپ کی محبت کا جزاک اللّہ

  • @irshadali-kw5mw
    @irshadali-kw5mw ปีที่แล้ว +2

    ماشاءاللہ بہت ہی مفید معلومات فراہم کی گئی ہیں شکریہ

  • @aamirmahmood6667
    @aamirmahmood6667 ปีที่แล้ว +4

    MashaAllah MashaAllah zbrdast good information

  • @AbidAli-ee4xc
    @AbidAli-ee4xc 10 วันที่ผ่านมา

    ❤❤❤❤❤❤ زبردست بہت خوب

    • @EasySkill
      @EasySkill  10 วันที่ผ่านมา

      بہت شکریہ

  • @abdulaganisuraleshawar8733
    @abdulaganisuraleshawar8733 ปีที่แล้ว +2

    Masha allah bohot qoob achha samjhaya aapne

  • @artlajawab7611
    @artlajawab7611 ปีที่แล้ว +5

    Nice information thanks for sharing this video jazakallah

  • @abdulrauf-o1s
    @abdulrauf-o1s หลายเดือนก่อน

    Bohat khoob sorat explained

  • @faisalarshid
    @faisalarshid 2 ปีที่แล้ว +4

    Excellent
    Good effort for beginners.

  • @muhammadkashif7335
    @muhammadkashif7335 18 วันที่ผ่านมา

    Mashaallha bahut acha samjha ap ny Thanks bhi

    • @EasySkill
      @EasySkill  10 วันที่ผ่านมา

      Welcome Mohtram

  • @papercup6665
    @papercup6665 27 วันที่ผ่านมา

    Mje ye to pta tha k nutral break ki wja se aisa hota lkn jo aj ap ne btaya k lamp k zariye kmal ho sir ap thanx

  • @pyaralisajwani740
    @pyaralisajwani740 ปีที่แล้ว +1

    Very good. very well explained. thanks

  • @msjanktk4882
    @msjanktk4882 หลายเดือนก่อน +2

    If the neutral wire is not disconnected then what will be the result?

  • @rosechannel9321
    @rosechannel9321 ปีที่แล้ว

    Nice information. Thanks. KHB Lahore

  • @ElectricResearch786
    @ElectricResearch786 ปีที่แล้ว

    Boht achy taraiky sy sir ap na detail di ha

  • @user-gm2ey9ur6u
    @user-gm2ey9ur6u 6 หลายเดือนก่อน

    thanks sir apnay har cheez wzahat say samjai hay

    • @EasySkill
      @EasySkill  5 หลายเดือนก่อน

      Boht shukrya

    • @EasySkill
      @EasySkill  5 หลายเดือนก่อน

      Boht shukrya

  • @asifmehmood5077
    @asifmehmood5077 ปีที่แล้ว +1

    بہت خوب

  • @FACTSTIMESHORTS
    @FACTSTIMESHORTS 2 ปีที่แล้ว +1

    Very helpful 👍🏻 video

  • @mytv5921
    @mytv5921 21 วันที่ผ่านมา

    Excillent

  • @practicallab
    @practicallab ปีที่แล้ว +5

    Simple bath neutral agr break ho to phase reverse ayega usi circuit may

  • @MuhammadBilal-hq7wl
    @MuhammadBilal-hq7wl ปีที่แล้ว +1

    Nice information sir

    • @EasySkill
      @EasySkill  ปีที่แล้ว

      Thanks Muhammad Bilal bhai

  • @KhalidAli-vc7rx
    @KhalidAli-vc7rx ปีที่แล้ว

    Very very nice veer G good work G super

    • @EasySkill
      @EasySkill  ปีที่แล้ว

      Bohat shukrya mohtram 🌹

  • @learnwithmmk
    @learnwithmmk ปีที่แล้ว +1

    V informative ❤️

  • @rajaibrar5256
    @rajaibrar5256 ปีที่แล้ว +2

    I was knowing but u provided logic.
    Excellent briefing

    • @EasySkill
      @EasySkill  ปีที่แล้ว

      Thanks

    • @prince-khan55
      @prince-khan55 ปีที่แล้ว

      @@EasySkill but i have question ❓

    • @EasySkill
      @EasySkill  ปีที่แล้ว

      @@prince-khan55 yes

    • @prince-khan55
      @prince-khan55 ปีที่แล้ว

      @@EasySkill generator ki to dono wire py tester glow hota hai agr us me koi cheez na bhi lgao mean usky main sockets py tester dono points pu glow hota hai why ????

    • @prince-khan55
      @prince-khan55 ปีที่แล้ว

      @@EasySkill answer my question

  • @qayyummuhammad5585
    @qayyummuhammad5585 ปีที่แล้ว

    Very good information

  • @mohammedkamaluddin4725
    @mohammedkamaluddin4725 8 หลายเดือนก่อน

    Thank you for giving this important information

    • @EasySkill
      @EasySkill  8 หลายเดือนก่อน

      You are welcome dear

  • @AliHaider-hq4kf
    @AliHaider-hq4kf ปีที่แล้ว +3

    neautral ka tester pa glow sub se bari reason ye hoti ha 😃 k jis transformer par hmara meter laga hota ha us transformer ko wo ground nhi krte😑😑😑...Jis k wja se neutral phase ki tarah glow krta h...mere sath bhi yehi msla tha ma ne phr apna meter utrawa kr 60 meter dor dosre transformer par apna meter lagwa liya tha or wo transformer properly ground tha jis k waja se neautral wala msla hal howa tha🥰🥰🥰

    • @prince-khan55
      @prince-khan55 ปีที่แล้ว

      itni bhi kya zarurat thi jo meter he itni door lagwa liya kya dono wire py phase anay se koi masla hota hai mean electricity mein?????

    • @AliHaider-hq4kf
      @AliHaider-hq4kf ปีที่แล้ว

      @@prince-khan55 yes bro msla hota ha😃😃 khuda na kre agr kisi ko current lg jae to zyada shock lgta ha Neautral ki waja se or appliances bhi properly work nhi krte or bhi bht saare misail hn jo sirf electrician hi smj skta ha

    • @prince-khan55
      @prince-khan55 ปีที่แล้ว

      @@AliHaider-hq4kf good answer dear 👍

  • @tahirmughal5100
    @tahirmughal5100 ปีที่แล้ว

    Very informative video

  • @shahabdmc7928
    @shahabdmc7928 ปีที่แล้ว

    Very useful infa, Thanks

  • @iqbalhussain1001
    @iqbalhussain1001 หลายเดือนก่อน

    Good sharing

  • @malikshaban2447
    @malikshaban2447 ปีที่แล้ว +32

    اگر ٹرانسفرمر سے نیوٹرل نہیں آرہی مطلب اس کا ارتھ ڈسکنکٹ ہے تو بھی ٹیسٹر دونوں سائیڈ پہ چلے میرے تجربے کے مطابق ؟

  • @Faisalkhan-bt3nw
    @Faisalkhan-bt3nw ปีที่แล้ว

    Beautiful 💞
    Nice video 📷

  • @mrbhadrashahi720
    @mrbhadrashahi720 ปีที่แล้ว

    Thank you sir. For clear my doubt.

  • @shahjimohammad7570
    @shahjimohammad7570 ปีที่แล้ว

    بہت معلوماتی

    • @EasySkill
      @EasySkill  ปีที่แล้ว

      بہت شکریہ 🌹

  • @dramasreview623
    @dramasreview623 ปีที่แล้ว

    Useful information

  • @ahmedmiyan1968
    @ahmedmiyan1968 ปีที่แล้ว

    Good informtion thanks

  • @kausarraza4118
    @kausarraza4118 ปีที่แล้ว

    Excellent knowledge 👍

  • @ajmalhussain2733
    @ajmalhussain2733 23 วันที่ผ่านมา

    Beautiful ❤❤❤❤

  • @drrafiquebhatti2019
    @drrafiquebhatti2019 24 วันที่ผ่านมา

    Nice

  • @safdarhussain7429
    @safdarhussain7429 ปีที่แล้ว

    Boht shukria bhai

  • @befaizaseer
    @befaizaseer ปีที่แล้ว

    Very good sir

  • @SaadullahMir
    @SaadullahMir ปีที่แล้ว

    Thanks for a nice info

  • @MIAN-MAHMOOD
    @MIAN-MAHMOOD ปีที่แล้ว +1

    Boht khob

  • @MTACompany
    @MTACompany ปีที่แล้ว

    جزاک اللہ

  • @riazkhokhar4141
    @riazkhokhar4141 ปีที่แล้ว

    Good explanation

  • @faizahmed6000
    @faizahmed6000 28 วันที่ผ่านมา

    Thanks

  • @barhingazadkashmir1801
    @barhingazadkashmir1801 หลายเดือนก่อน

    Zabardast

  • @AhsanKhan-ps1cj
    @AhsanKhan-ps1cj ปีที่แล้ว +1

    Good

  • @faheamakhtar74
    @faheamakhtar74 3 วันที่ผ่านมา

    ❤❤❤❤

  • @user-zt6xy6ic6f
    @user-zt6xy6ic6f ปีที่แล้ว

    Very nice

  • @mohammadumair4061
    @mohammadumair4061 ปีที่แล้ว

    Mashallah good

  • @user-mh5ev3nf6n
    @user-mh5ev3nf6n หลายเดือนก่อน

    If neutral is short there's in point connection of line so
    Phase has to show in both wires but not equaly.

  • @Unknownxyz-cb6lz
    @Unknownxyz-cb6lz ปีที่แล้ว

    Excellent

  • @rajabagain2179
    @rajabagain2179 ปีที่แล้ว +3

    Very well explained. Now ye bhi sath bta dete to question arise na hota k jab Neutral disconnected ho or tester dono sides pe li8 show kare to kese pata lagy ga k N kpn sa point he or Phase kon sa ahe? I think kam li8 wala N or ziada li8 wala P hota he....

    • @ADElectric
      @ADElectric ปีที่แล้ว +1

      G Bilkul but neutral wire ager full mis ho ge to tester full Glow Kary ga ..q k phase return full speed say ho ga

  • @hassanm1367
    @hassanm1367 ปีที่แล้ว

    Super 👍

  • @nicknamemj
    @nicknamemj ปีที่แล้ว +2

    Doosri barri reason: unbalanced neutral current from distribution transformer to consume end

  • @zeeshanahmad2590
    @zeeshanahmad2590 ปีที่แล้ว

    super 💯👑

  • @simplelifelivinginmindanao
    @simplelifelivinginmindanao 2 ปีที่แล้ว +2

    Nice sharing 👍

  • @sattarbhatti2222
    @sattarbhatti2222 ปีที่แล้ว

    very nice

  • @thepearlhouseofeducation521
    @thepearlhouseofeducation521 2 ปีที่แล้ว +1

    Good job

  • @demobashiremail7705
    @demobashiremail7705 11 หลายเดือนก่อน

    Good vide

  • @hrhashmi61
    @hrhashmi61 21 วันที่ผ่านมา

    Dear , if Neutral of your WAPDA PMT has n not been properly earthed, then in all sockets tester will necessarily lit in neutral as well.

  • @MalikSaeed408
    @MalikSaeed408 หลายเดือนก่อน

    Sshukria.

  • @gmapple3828
    @gmapple3828 9 วันที่ผ่านมา

    Mere sath aisa kai baar ho chukka hai... Kai baar aisa b howa hai k wire he damage thi... Or baaz dafa breaker b damage ho jaye tb b aisa ho jaata hai....

  • @alsyedhardweirstore2322
    @alsyedhardweirstore2322 11 หลายเดือนก่อน

    Smart move

  • @3dgamingworld8
    @3dgamingworld8 2 ปีที่แล้ว

    Informative video

  • @ythelper620
    @ythelper620 ปีที่แล้ว

    Thanks Bro😊 7:14

  • @user-tp6fr9er2y
    @user-tp6fr9er2y ปีที่แล้ว

    Achha breif kiya ha.
    Ba'az mulkoon main domestic supply do phases par mushtamil hoti ha yani 110v each phase aisy soorat main jub circuit banta ha to aik phase rah jata ha aur doosra neautral.
    Behtar yeh hota ha tester par rely karnay ki bajaiy multimeter ka istemaal kiya jaiy ta kay circuit voltage maloom ho sakain.

  • @MTACompany
    @MTACompany ปีที่แล้ว

    اچھی ویڈیو

  • @tanveerarif6399
    @tanveerarif6399 ปีที่แล้ว

    Mashallah

  • @TariqMehmood-jv2us
    @TariqMehmood-jv2us ปีที่แล้ว +1

    السلام و علیکم بھائی ہر کوئی phase کو ٹیسٹر سے جلا کر بتا دیتا ھے مگر Nutral کو چیک کرنے کا طریقہ نہیں بتاتا

  • @nasirnaazvlogs5883
    @nasirnaazvlogs5883 ปีที่แล้ว +1

    Nice bro

  • @mbashir5426
    @mbashir5426 ปีที่แล้ว

    wow

  • @btech1708
    @btech1708 ปีที่แล้ว

    Wow

  • @muhammadshafiq3441
    @muhammadshafiq3441 ปีที่แล้ว +4

    Generally, on Adopter/ Extension board, the testers glow on both sides of the sockets. The reason may be that there is something connected to the other socket on the wallboard from where we have taken the supply for Extension.
    You have not told me that the intensity of light in the tester on both sides will be different. Light in the tester on the Phase point/ terminal will be more than on the neutral point.
    You have not informed me that if the current is flowing on both terminals what should be the precautions to be adopted by electricians or any lay working on the switchboard?
    Please also tell us what should we do so that the current is not passed through the neutral wire and is not shown on Sockets on both sides, especially in house wiring..

    • @ADElectric
      @ADElectric ปีที่แล้ว +2

      Simple solution if the tester light glow on neutral point ...so it's called neutral wire missed on switch board

    • @ADElectric
      @ADElectric ปีที่แล้ว

      @@prince-khan55 yes

    • @nisaryousaf1102
      @nisaryousaf1102 ปีที่แล้ว

      Simpal
      👇👇👇👇
      Arth cnact the neutral

    • @mushtaqmalik2183
      @mushtaqmalik2183 ปีที่แล้ว

      Qio

  • @zohaibarshad3783
    @zohaibarshad3783 10 วันที่ผ่านมา

    Earth na aaye tb yah masla hota hai

  • @artlajawab7611
    @artlajawab7611 ปีที่แล้ว +1

    Earth point pr current kyun aata ha?iske baare mein bhi bata dijia

    • @ADElectric
      @ADElectric ปีที่แล้ว

      Earth ka phase wire k sath tech ho jana

  • @jonykhan4395
    @jonykhan4395 11 หลายเดือนก่อน

    Good work. how tester works with phase while there is no neutral wire inside the tester?

  • @miansahib9590
    @miansahib9590 ปีที่แล้ว

    3 times too long just to get to 8 minute POINT and still didn' t take the time to solve neutral or proper diagnistics to avoid electrocution ALL TOO COMMON IN PAKISTAN.

  • @usmanaliali1927
    @usmanaliali1927 ปีที่แล้ว

    ❤❤❤

  • @englishacedemy6456
    @englishacedemy6456 10 หลายเดือนก่อน

    sir teak ha mery zaty 6year experience ha bulding main wiring karta hu jab kesy gar main bijly hrab hugai tu main tester sa dric souch ko test karta hu jb ye masla hugai tu mujy daric andaza hugai k wabda ke line nutrn hrab ha 🎉

  • @SajjadKhan-jo5mz
    @SajjadKhan-jo5mz หลายเดือนก่อน

    Neutral brack hoti hay is leay

  • @muhammadmunawar256
    @muhammadmunawar256 ปีที่แล้ว

    What is remedy if neutral is broken n tester telling current in both phase n neutral holes.

  • @AbdulsattarmoosaniMoosan-jy4ii
    @AbdulsattarmoosaniMoosan-jy4ii 2 หลายเดือนก่อน +2

    آگر ایسی ھی طرح سے دونوں شاقٹ میں فیس ارھا ھو تو کیا کرنا چاھےء

    • @SajjadKhan-jo5mz
      @SajjadKhan-jo5mz หลายเดือนก่อน

      Neutral brack hoti hay is leay
      ماٸنس تار بریک ھے اس کو چیک کریں

  • @Xyz-sd7ub
    @Xyz-sd7ub ปีที่แล้ว +2

    Whenever negative is disconnected from terminal.

    • @ranatahir2845
      @ranatahir2845 ปีที่แล้ว

      Right

    • @adamvayani3200
      @adamvayani3200 ปีที่แล้ว

      MERA LED TV BND HOGAYA HE
      AB KESY CHECK KRO PLUG B THEK HE

    • @EasySkill
      @EasySkill  ปีที่แล้ว

      Step by step Trace karn k tv ki supply main voltage aa ray hain ya ni agar supply main in put AC hai or output DC ni hai to supply main fault hai or supply main AC ni aa raha to wire or sockt check krain

  • @user-nb6fi2fw4b
    @user-nb6fi2fw4b ปีที่แล้ว

    Nutaral ma ka masla be hota he likan reverse bajly be hosakty hr

  • @user-nb6fi2fw4b
    @user-nb6fi2fw4b ปีที่แล้ว

    Nutaral disconnect ka mslaa hota ha likan oulty bajly kasa be masla be hota ha

  • @ishaqmalik2504
    @ishaqmalik2504 ปีที่แล้ว

    Bhai Saab agar aaj kal b koi electrician is tara ki wiring karta hai to woh totally rong hai, lights or sockets ka circuit alag hota hai, or cables b different size ki use hoti Hain,

    • @EasySkill
      @EasySkill  ปีที่แล้ว

      Aap keh sakty hain thanks for your comment

  • @nomanrajpoot9185
    @nomanrajpoot9185 ปีที่แล้ว

    THANKU sir

  • @aamirbassali2696
    @aamirbassali2696 ปีที่แล้ว

    sir 10 kw 230 volt 43.5 amp 1500 rpm syncronous singel phase generator main bridge ractifire main kitni velue kay diode lgte hain.please hellp me.

    • @EasySkill
      @EasySkill  ปีที่แล้ว

      50Amps metallic minimum

  • @HasibUllah-bp4nr
    @HasibUllah-bp4nr 3 หลายเดือนก่อน

    السلام علیکم و رحمۃ اللہ
    بھائی میرے پاس 250 واٹ کے 4سولر پینلز ہیں کو کہ ہر ایک پینل علیحدہ علیحدہ وولٹیج 52/54 دیتے ہیں جبکہ ہر پینل 01 ایمپئر بھی پورا نہیں دیتا. باکس میں 3 کنکشنز ہیں اور صرف ایک ڈائیوڈ 15 ampکا جبکہ ایک جمپر لگا ہوا ہے، وولٹیج زیادہ کیوں آرہے ہیں اور ایمپئر کو کیسے بڑھایا جا سکتا ہے. مہربانہ فرما کر رہنمائی فرمائیں.

  • @IM-Imran007
    @IM-Imran007 ปีที่แล้ว

    To phr cheezy jlti q ni? Jb dono trf phase a ra hai to? Please.
    Or ik r question kuch kmro me sockets direct run kr ry switch on kiye bina.. Wo q? Neutral miss hai to chezy run nhi hni chahiye wo b sahi run ho rhi...

    • @EasySkill
      @EasySkill  ปีที่แล้ว

      Dear chezain jalti is liey nahin k un jo phase aa raha hai wo singal hai dibble nahin wahi single phase hi wires main ghoom raha hota hai apney friend Nutural ki tlash main or Nutural ma miley to phase hota to hai magar be faeda

  • @mtcemngr5292
    @mtcemngr5292 ปีที่แล้ว

    Mamooli bath. dc supply meñ dirf aek terminal hee jalegaa, negative terminal.

  • @duniafani9570
    @duniafani9570 ปีที่แล้ว

    Sir nutrul me tester on hota hai or phase py nhi is py video banaye or bataye please kia msla ho skta hai

  • @hadishah3853
    @hadishah3853 ปีที่แล้ว +1

    Is ko Neutral nhn mil Raha ,Return dono teref har am I write?

    • @EasySkill
      @EasySkill  ปีที่แล้ว

      Yes right 👍

  • @sarwerkhan6254
    @sarwerkhan6254 ปีที่แล้ว

    Haray Bhai siress hai test lamp banalo ya siress bord banalo

  • @AbdurRehman-cx6it
    @AbdurRehman-cx6it 11 หลายเดือนก่อน

    کرنٹ دو نوں پائنٹ میں موجود اسکا مطلب ہے نیوٹرل کٹ۔ لیکن بلب پھر بھی جلتا ہے کیوں

    • @EasySkill
      @EasySkill  11 หลายเดือนก่อน

      یہی تو بتایا ہے

  • @muhammadibtesam8716
    @muhammadibtesam8716 ปีที่แล้ว +1

    without neutral wire disconnection there comes a chance that the two wires show alive in tester why then ?

    • @EasySkill
      @EasySkill  ปีที่แล้ว

      Because any thing is connected and running in the parallel of this switch board in other socket or other board in that situation it means the circuit is closed/completed

  • @ShahbazHussain001
    @ShahbazHussain001 ปีที่แล้ว

    Background music off rakha krein

  • @Go4Truth
    @Go4Truth ปีที่แล้ว

    to aise breaking point ko kaise dhonde k yahan se neutral wire toote ha ya disconnect hoi ha wo point kaise dhonden ge?

    • @EasySkill
      @EasySkill  ปีที่แล้ว

      Testing holder se ya multimeter se poin by point pichy ki traf trace kartey jaeyn