Sir Panasonic ka ac hai outdur 30 second me off ho ja raha hai .. company wale aya tha kulka lagaya or 4 din chala phir ohi problem a raha hai kya karu
Ac का डिसचार्ज प्रेशर 350 हो रहा है। R22 gas है और कॉलिंग बिल्कुल ना के बराबर हो रही है और बैक प्रेशर 70 का आ रहा है डिसचार्ज प्रेशर कितना होना चाहिए और डिसचार्ज प्रेशर बढ़ क्यों रहा है
@@Abhishek_yadav004 brother everyone knws it ki garm hawa upr uthti h, pr jb aap air speed se blow kr rhe h, or samne blockade h, to hawa bounce ho kr wps ayegi uske bad upr jayegi, or itne me ac trip hone ki condtion create ho jyegi.
Kharab hua kya tha ac
Inverter ac ka pcb price kitna hain approx bata na bhi plz 🙏
4000 REPAIR COST
NO BROKER SE INSPECTION KE LIYE BULAO AND USNE PATA KARO PRICE AND OFFLINE DEAL; MAT KARNA
khatron k khiladi ho bhai tum toh
Matlab teri galti se customer ka pcb kharab huya , galat jga pe outdoor lga diya 😂😂😂
BHAI AAP MAX KITNA DUR JATE HO
Bhai abhi may me hi ac lgaya hai lekin engineer ne bina vaccum kare hi fit kar dia usse kya problem aa skti hai?
Panasonic ka lia h kya
Sir Panasonic ka ac hai outdur 30 second me off ho ja raha hai .. company wale aya tha kulka lagaya or 4 din chala phir ohi problem a raha hai kya karu
Outdoor unit के अगल - बगल space नहीं है। copper pipe पर insulation भी नहीं है।
Ac का डिसचार्ज प्रेशर 350 हो रहा है। R22 gas है और कॉलिंग बिल्कुल ना के बराबर हो रही है और बैक प्रेशर 70 का आ रहा है डिसचार्ज प्रेशर कितना होना चाहिए और डिसचार्ज प्रेशर बढ़ क्यों रहा है
Question to puch diya lakin reply ka wait na kare .....
Ehsan bhai froom telangana hamara Refregilatet work nahe karraha hay ap se bath karna hay bhai plz reply
Kal Dhunha, Babhani aayega
Kitna kharcha aaya customer ko
Bhai reply nahi karte hai 😢😢😢😢😢
Pcb to repair ho jati hai . New change kerne ki jarurat to nahi thi
Pcb repair hone ke lyea jgh bhi hona chahiye sb kuch na hone pr last m new lgana pdta h majburi h bhai
@@swajeetpatel6823 repair ka cost bahut kam aayega compare to change kerne ke . New pcb matlab ( 4000-5000. Rs)
❤❤
Copper pipe insulation nahin hai..
Hitachi ac ke old model per videos banao
Wrong installation ehsan
Bhai lg refrigerator water leak videos lavo
Haam paresan ho chuki hai
Water nikal kar
Arey bhai, kuchh safety se kaam karo, aise latak ke kaam naa karo, rassi vagera bhandh ke utara karo..
Haan mujhe to dekh ke hi darr lag raha tha 😮😮 pata nhi bhai ne kaise kiya ?? 😢
wrong installation, outdoor unit is blocked.
upr open h to utna dikkat nhi hoga lekin ha galat jgh lga h outdoor unit
@@Abhishek_yadav004 bhai outdoor fan se, hot air bounce ho kr wpis aayegi, or zada grmi bdhne se ac jldi trip krega.
@@gauravkataria4318 garm hawa halki hoti h to wo turant upr chle jaygi....lekin at the end dikkat hoga in long run...
@@Abhishek_yadav004 brother everyone knws it ki garm hawa upr uthti h, pr jb aap air speed se blow kr rhe h, or samne blockade h, to hawa bounce ho kr wps ayegi uske bad upr jayegi, or itne me ac trip hone ki condtion create ho jyegi.
@@gauravkataria4318 correct
Hi