E1 error code in in carrier Inverter AC, carrier Inverter AC error code E1

แชร์
ฝัง
  • เผยแพร่เมื่อ 13 ต.ค. 2024
  • Table of Error Codes
    EO: (OL 1 Times) Indoor unit EEPROM parameter error.
    E1: (OL 2 Times) Indoor / outdoor units communication error.
    E3: (OL 4 Times) The speed of the indoor fan has gone out of control.
    E4: (OL 5 Times) Indoor room temperature sensor T1 open circuit or short circuit.
    E5: (OL 6 Times) Evaporator coil temperature sensor T2 open circuit or short circuit.
    EC: (OL 7 Times) Refrigerant leak detection.
    F1: (OL 2 Times, TL on) Outdoor ambient temperature sensor T4 open circuit or short
    F2: (OL 3 Times TL on) circuit. Condenser coil temperature sensor T3 open circuit or short circuit.
    F3: (OL 4 Times, TL on) Compressor discharge temperature sensor T5 open circuit or short circuit.
    F4: (OL 5 on) Outdoor unit EEPROM parameter error.
    F5: (OL 6 on) The speed of the outdoor fan is out of control.
    P0: (OL 1 flash) Strong current protection over IPM malfunction or IGBT.
    P1: (OL 2 flash) Over voltage or low voltage protection.
    P2: (OL 3 flash) High temperature protection of compressor top diagnostics and solutions.
    P4: (OL 4 flash) Inverter compressor drive error.
    F8: (OLF 9 Times) Compressor Suction Temperature sensor defective.
    L3: (OLF 33 Times) Drive Phase current overload defective.
    L4: (OLF 34 Times) Phase Current Sampling defective.
    FO: (OLF 13 Times) Outdoor AC Current protection.
    L1: (OLF 31 Times) Drive bus voltage overload protection.
    L2: (OLF 32 Times) Drive bus voltage overflow protection.
    P5: (OLF 14 Times) Compressor phase current protection.
    P6: (OLF 16 Times) Outdoor over high/over-low DC voltage protection.
    P7: (OLF 17 Times) IPM Temperature over heat protection.
    P8: (OLF 18 Times) Compressor discharge Temperature overheat protection.
    P9: (OLF 19 Times) Cooling indoor Unit anti-freezing protection.
    PU: (OLF 20 Times) Cooling Outdoor Coil over heat protection.
    PE: (OLF 21 Times) Heating indoor coil over heat protection.
    PC: (OLF 22 Times) Cooling outdoor ambient Temperature over-low protection.
    PH: (OLF 23 Times) Heating outdoor ambient Temperature over-high protection.
    E2: (OLF 27 Times) Zero crossing signal detection error.
    What are error codes anyway?
    Error codes help people know when their air conditioning system needs to be repaired or isn’t working optimally. Each error code has a meaning to help you understand the problem and what needs to be done to fix it.
    Below are the error codes for Carrier systems and the matching explanation.
    If an E1 error code shows up in your air handler, that means there is a communication error either with the indoor unit or the outdoor unit. The causes for this could be a wiring mistake, or a faulty control board with the indoor unit or the outdoor unit.
    ‪@sainisolutionrepairing‬
    #sainisolutionrepairing

ความคิดเห็น • 16

  • @SamimKhan-jp4ei
    @SamimKhan-jp4ei ปีที่แล้ว +2

    Problem solve ho gay👍👌

  • @SAHNIAIRCONDITION
    @SAHNIAIRCONDITION 3 ปีที่แล้ว +4

    Very good sir g

  • @ravjohn2
    @ravjohn2 ปีที่แล้ว +1

    Can you explain in english what you repaired to solve this error E1?

    • @ravjohn2
      @ravjohn2 ปีที่แล้ว

      My Carrier worked fine for 4 years and now it shows error E1

    • @azkhan8407
      @azkhan8407 ปีที่แล้ว +1

      He just changed the connection wire of outdoor unit

  • @Manjeetelectronitips
    @Manjeetelectronitips 2 ปีที่แล้ว +4

    Out dor khol k dekho fan ek hi hota h

    • @purnimaservices4431
      @purnimaservices4431 2 ปีที่แล้ว

      😄😄😄😄😂thik bola Alag se fan nahi hota

  • @diljeetsingh389
    @diljeetsingh389 2 ปีที่แล้ว

    NF ka matalab kiya hai sir

  • @devmalakar2412
    @devmalakar2412 ปีที่แล้ว

    Wire change karne ke bad bhi nahin chal raha hai auto aur

  • @seemantgupta8748
    @seemantgupta8748 6 หลายเดือนก่อน +1

    kitna kharcha hota h isme?

    • @Kachoora
      @Kachoora 4 หลายเดือนก่อน

      Mera 5000 ka kharcha ho gaya 😅

    • @seetalparmar3510
      @seetalparmar3510 4 หลายเดือนก่อน

      1ooo

    • @nileshsonar9
      @nileshsonar9 4 หลายเดือนก่อน

      ​@@Kachoorakya problem tha

    • @nikhilkale1840
      @nikhilkale1840 3 หลายเดือนก่อน +1

      Maine to bhangar me dal diya ac 8000 ka kharcha aya, PCB ka issue tha outdoor unit me

  • @GulshanKumarRao-cs5iv
    @GulshanKumarRao-cs5iv 4 หลายเดือนก่อน

    Gajab dhokebaj hai