Very nice fix, BUT. while re fixing the wire to the induction coil the way you did might have got the fan running again, there is a reason why the coil was burned and open circuit. You did not find or fix the fault, this means that the coil will continue to overheat and sometime in the future as a best case cenario the fan will stop working again. As a worst case cenario the fan will actually overheat and cause a fire which could at worst, end up in some form of fatality, and at best, result in an insurance claim for the funds to rebuild your home. Just a thought, and i hope that this never happens.
Yes, with evidence of a screw driven through a bundle of wires that carry mains voltage. An open circuit has been replaced by multiple shorts to companion wires, some of which will be tenuous enough to create resistance. Current across that resistance causes heat, so expect it to die much sooner than one would expect. Ask yourself whether any standards agency on the planet would consider that incriminating screw placement approved for safety. Don't burn your house down to save a little cash on maintenance, you could be found criminally liable for concealing a dangerous repair.
Excellent service .
Excellent service
Wow that was Aewsome. I didn;t know that screw did the trick. so i guess it alows the magnetic field to rotate the blades as needed.😎
Very helpful
Nice
👍👍
Very nice fix, BUT. while re fixing the wire to the induction coil the way you did might have got the fan running again,
there is a reason why the coil was burned and open circuit. You did not find or fix the fault, this means that the coil
will continue to overheat and sometime in the future as a best case cenario the fan will stop working again. As a
worst case cenario the fan will actually overheat and cause a fire which could at worst, end up in some form of
fatality, and at best, result in an insurance claim for the funds to rebuild your home. Just a thought, and i hope that
this never happens.
بله توضیحات شما صحیح است، من این کار را انجام دادم ولی بعد از ۵ ماه دوباره سوخت، به دلیل تولید گرمای بیش از اندازه
Yes, with evidence of a screw driven through a bundle of wires that carry mains voltage. An open circuit has been replaced by multiple shorts to companion wires, some of which will be tenuous enough to create resistance. Current across that resistance causes heat, so expect it to die much sooner than one would expect. Ask yourself whether any standards agency on the planet would consider that incriminating screw placement approved for safety. Don't burn your house down to save a little cash on maintenance, you could be found criminally liable for concealing a dangerous repair.
As soon as I saw the screw I said hell nah😅
فيديو جميل جداً
Hey - Why is it bad to reverse ceiling fan direction before the fan stops moving? I did this a few times. Did I damage my fan?
It is not really bad. If you want me to explain replay. And so you did not damage your fan
You tested the condenser or capacitor..you wrote condenser in the description
Kosh din ke baad coil jal jayega pakka
This is a bad repair job!! You have now shortened the effective length of that coil, hence over-heating which will lead to a fire.
Please what's the best way to do it?
B e r i s i k pret😅
Is this a tutorial on how to start a fire in the house? This kind of video should be taken down!!!
😅😅😅
මොකකද බන් ඒබලු හැදිල්ල ඕක ගලවල ඔතන්න තිබුනනෙ ඒ සෙට්ටෙක විතරක්