IR compressor trips with check mtr rotation

แชร์
ฝัง

ความคิดเห็น • 8

  • @augustineghenry7082
    @augustineghenry7082 5 ปีที่แล้ว

    Thank you Vijaykumar Pawar got similar problem with our IR compressor tripping off at mtr rotation I will have a look at it again.

  • @addaelect
    @addaelect 4 ปีที่แล้ว

    We face a Motor Rotation error what should we do ?

    • @vkumarelectrotech
      @vkumarelectrotech  4 ปีที่แล้ว +2

      In which machine you are facing. If it is compressor remove air tube of sump pressure tube and just give air by mouth or other source and start compressor immediately. connect

    • @vkumarelectrotech
      @vkumarelectrotech  4 ปีที่แล้ว +2

      Check motor rotation means positive pressure edge is not detected at starting of Compressor at sump pressure sensor. Apply T connector at sump pressure sensor and give pressure when you start compressor after compressor starts blind that air tube from where you have given pressure. Chech air tube leakage at sump pressure connection and compressors pressure head it's working properly to resolve this problem permanently. It may because drive is applied to Compressor motor to start and acceleration time is longer.

    • @addaelect
      @addaelect 4 ปีที่แล้ว

      Ok thank you....we got it
      Belt is burn nd pistion jammed

    • @vkumarelectrotech
      @vkumarelectrotech  ปีที่แล้ว

      just fill some air in sump pressure transmitter air tube and connect air tube and immediately start compressor

  • @manojsingh-sk6qm
    @manojsingh-sk6qm ปีที่แล้ว

    Good morning sir my ir compressor ir37 model alarm come ck motor rot

    • @vkumarelectrotech
      @vkumarelectrotech  ปีที่แล้ว

      just fill some air in sump pressure transmitter air tube and connect air tube and immediately start compressor