Hello sir I hope everythink is ok . Well i do exactly what the video shows and when a solar panel is close to the " model" lines when i impoted to pvsyst it shows the following " PV filed trina 3142 face #1 is very close to the "model" . The solution is to move the partcular solar panel or erase it or check the box in the tools section for disable field for interprenetration check . Could you help ? thanks
Hi Amiya! thanks for the videos! Near shadings 3d scene shows: The Shading area is far larger than the PV modules (Shadings=54246 m2 and Orientation=35 m2). I've changed Absolute Maximum Shading/Field area Ratio" to 1600 but it did not work. Can u help me?
Hi Marcelo. This error actually coming because the Number of modules you consider in the System tab is not equal to the Near Shading no. of modules. Thanks, Amiya All About Solar
@@AllAboutSolar Thanks Amiya! I don't know why... I have imported the project from Sketchup. Altogether are 18 pv modules but the difference is very discrepant.
yes sir I was using the User Pv database only. I have added the module specs Module name dimension wattage. Then turned on the user pv database. Then selecting the added module. Then no. Of modules, no. Of stack then continue But nothing appearing on the selected surface.
PID Loss: Potential Induced Degradation loss. Due to the aluminium frame of Solar Module some voltage drop happen that is known has PID. LID : Light induced degradation. I already explain the same on PVsyst Episode 4 part 1. Please watch it again. Thanks, Amiya All About Solar
@@AllAboutSolar hii I can only find cad file and images to export. Couldn't find a h2p file. I request you to make a video on this as this is a very sought after question
Thank you very much dada for details explaining
Worth watching
Hello sir I hope everythink is ok . Well i do exactly what the video shows and when a solar panel is close to the " model" lines when i impoted to pvsyst it shows the following " PV filed trina 3142 face #1 is very close to the "model" . The solution is to move the partcular solar panel or erase it or check the box in the tools section for disable field for interprenetration check . Could you help ?
thanks
thanks, worth the time!!!
Thanks for your words
Great Work Dada..
Thanks.
good
Hi Amiya! thanks for the videos! Near shadings 3d scene shows: The Shading area is far larger than the PV modules (Shadings=54246 m2 and Orientation=35 m2). I've changed Absolute Maximum Shading/Field area Ratio" to 1600 but it did not work. Can u help me?
Hi Marcelo. This error actually coming because the Number of modules you consider in the System tab is not equal to the Near Shading no. of modules.
Thanks,
Amiya
All About Solar
@@AllAboutSolar Thanks Amiya! I don't know why... I have imported the project from Sketchup. Altogether are 18 pv modules but the difference is very discrepant.
Great Bro.!
Can you please do the several orientation SketchUp video with import in Pvsyst.
OK. I will try to make a short video about the same.
Thanks,
Amiya
All About Solar
I Hope you are fine Bro.
When will we expect Videos on PVSyst7 version.
My man you are flying. Try to keep it slower but a good video.
Yeah I know it's little bit faster but time constraint push us to make it quick... You can pause it and similarly try to do the same in PVsyst.
could not add modules using user database
But modules can be added using Skelion Database
sir please help
I have sketch up 23
You can add from ‘User PV Database’
yes sir I was using the User Pv database only.
I have added the module specs
Module name dimension wattage.
Then turned on the user pv database. Then selecting the added module.
Then no. Of modules, no. Of stack then continue
But nothing appearing on the selected surface.
Thank you!
You’re most welcome brother
Do you give a course for Pvsyst?
Can you give me the link to download the plugin?
There is no plugin required brother try to watch the video carefully and follow the steps.
Bhai ye pid loss and lid loss q hota hai ??
PID Loss: Potential Induced Degradation loss. Due to the aluminium frame of Solar Module some voltage drop happen that is known has PID.
LID : Light induced degradation. I already explain the same on PVsyst Episode 4 part 1. Please watch it again.
Thanks,
Amiya
All About Solar
@@AllAboutSolar Ok Brother Thanks so much
Can you not use the skellion for everything. We want a tutorial without using skellion pls
Hi Amiya. Thanks for the videos. Is it possible for importing Helioscope Layout to PVSyst ?
Yes, you can. You have to save your Helioscope 3D file as .H2P file.
th-cam.com/video/LMdU16kkXdg/w-d-xo.html please watch this video for reference.
@@AllAboutSolar hii I can only find cad file and images to export. Couldn't find a h2p file.
I request you to make a video on this as this is a very sought after question