Controlling your Sicce SDC pump with Apex Fusion

แชร์
ฝัง
  • เผยแพร่เมื่อ 17 พ.ย. 2024

ความคิดเห็น • 12

  • @robbychase5225
    @robbychase5225 2 ปีที่แล้ว +2

    Thank you for this. I had no luck figuring it out on my own and the manual was no help.

    • @ogreefandaquariums411
      @ogreefandaquariums411  2 ปีที่แล้ว

      My pleasure..its not easy but once its working ..its very cool

  • @sanpietroprogettista9887
    @sanpietroprogettista9887 3 ปีที่แล้ว +1

    Thank you for sharing.

  • @garycumbo1092
    @garycumbo1092 3 ปีที่แล้ว +1

    Thanks I own two sicce sdc power heads and the sdc return 6.0

  • @BigDaddyJGG
    @BigDaddyJGG 7 หลายเดือนก่อน

    Thanks for the great vid. What is Wet FR and Wet FL. I am getting a send error. Also overnight Apex runs off my sicce.

  • @BALD8BIL
    @BALD8BIL 2 ปีที่แล้ว +1

    Great video I would like to thank you for sharing it with us I have the sicce 7.0 pump and now my apex fusion is not control it now so I will have to see why. I do have another question I see on your Apex Fusion you have reminders showing up how do you do that

    • @ogreefandaquariums411
      @ogreefandaquariums411  ปีที่แล้ว +1

      Hey nro sorry for the late reply.. read this and if you have questions just ask
      www.reef2reef.com/threads/apex-reminder-calendar-sync-notifications.686784/

  • @Fluke-h6z
    @Fluke-h6z 2 ปีที่แล้ว +1

    I have a question for you, when you press feed mode, does the pump turn off completely?

    • @ogreefandaquariums411
      @ogreefandaquariums411  2 ปีที่แล้ว +1

      Depends on your programming of the feed mode.. I have it set to shutdown the return pump and power heads for a period of time.. i can program the return pump to cut flow rate etc.. depends on the feed mode programming..

    • @Fluke-h6z
      @Fluke-h6z 2 ปีที่แล้ว

      @@ogreefandaquariums411 do you mind sharing the code to shut it off during feed mode? also i dont know if you have use the neptune core before, but if you did which one do you like more?

    • @ogreefandaquariums411
      @ogreefandaquariums411  2 ปีที่แล้ว

      @@Fluke-h6z puts this in the advance code section of your return pump
      If FeedA 000 Then OFF
      Feed has four mode A B C D
      Your program the time in which feed mode is active in the feed mode settings
      I dont wont my skimmer to overdlow whe n the rtn pump is off..so i put this code in my skimmer advance code section
      Fallback OFF
      If Output pump name = OFF Then OFF
      If Output pump name = ON Then ON
      Defer 002:00 Then ON
      If Power Apex Off 000 Then OFF
      This will cut of the skimmer anytime the rtn pump is off and wait 2min before cutting back on
      Also will kill the skimmer if my apex lose power