Numerical no. 2|| Machine Design||Transformer||Estimate average temperature rise of transformer tank

แชร์
ฝัง
  • เผยแพร่เมื่อ 8 พ.ค. 2024
  • Welcome to our educational TH-cam series on machine design, where we break down complex numerical problems into simple, understandable steps! Whether you're a engineering student, a budding designer, or just someone interested in the intricate workings of machines, this series is designed to help you understand various types numerical problems encountered in machine design course highly focus on bachelor level.
    Q. A 15 MVA Transformer has an iron loss of 80kW and full load copper loss 120 kW. The tank dimension are 3.5x3x1.4m. The transformer oil in cooled by water of 3 liter per sec in cooling coil. Estimate the average temperature rise of the transformer tank if the difference in temperature of inlet and outlet of water is 15°C. The specific loss dissipation of the tank wall is 10W/m²°C.