Making a Flexible Duct Connector

แชร์
ฝัง
  • เผยแพร่เมื่อ 23 ต.ค. 2024

ความคิดเห็น • 18

  • @PaulHVAC1
    @PaulHVAC1 2 ปีที่แล้ว +1

    Very good demo video. I really enjoyed it. Cheers!

  • @bw76528
    @bw76528 7 ปีที่แล้ว +3

    Good to see how this is done, thanks.

    • @davidnichols4229
      @davidnichols4229 7 ปีที่แล้ว +1

      Your canvas is made wrong because you don't know what your doing
      first thing is to add a 11/2" lap at both ends
      notch metal cutting one of the laps off leaving only the canvas material the other you notch away the part crimping the canvas leaving a 1 1/2" tab
      bend tab with pliers or tongs bend canvas over a table edge with smooth side inside for smooth air flow
      fasten metal tab at corners
      you should have 2 canvas tabs on the inside as well using a long throat heavy duty bag stapler staple canvas on the outside along the corner 4-5 in a row
      On the inside hold tabs together and staple then fold tabs towards the corner and staple again
      Done !!!!

    • @bincobinco5232
      @bincobinco5232 3 ปีที่แล้ว

      @@davidnichols4229 that Is one way of doing it yes but that’s not the only way, just because someone made it different doesn’t mean it’s made wrong 👍

  • @abdulhvac2395
    @abdulhvac2395 3 ปีที่แล้ว +1

    Thank you Very nice

  • @hangngoaigiare
    @hangngoaigiare 5 ปีที่แล้ว +2

    great thanks for sharing

  • @pauleohl
    @pauleohl 7 ปีที่แล้ว +1

    Perhaps you could make a video where you install the connector, showing what you do to the sheet metal portion of the connector and the duct ends to make a complete assembly.
    Is your spot welder a Durodyne portable welder on a stand? Was your connector material from Durodyne? To me, it looks like the long arms don't apply enough pressure and that is why you get the arcing.

  • @taimeiyeh2468
    @taimeiyeh2468 3 ปีที่แล้ว +1

    Hi, can this canvas flexible duct connector solve voice traveling in air ducts between rooms while air system is off.? also, can the canvas duct connector connect vent boots and air ducts to eliminate voice traveling between rooms?

  • @BLAZE5417
    @BLAZE5417 5 ปีที่แล้ว +1

    Sorry didn't catch your name; nevertheless, Thank You for your video.
    I do have a question. I have 2 of these flexible air duct joints and the rubber is not covering; its let go. Fortunately I qualified in my county for a new furnace. However when the county inspector inspected the new furnace installation; I notice the rubber on the flexible joint was flapping in the wind and ask don't they prepare the 2 flex joints: I was told no!. (? Cost of a furance but not 2 flex joints?)
    So this stubborn red head is on a mission; broken back or not. When the airconditioner on it freezes in the basement while on the main floor one's almost sweating; I'm thinking it's because the rubber in the flex joint is flapping as if nothing was there.
    Finally my question is until I can save up the money to build what you showed in your video the proper way 》My question is can I use the High temp aluminum foil duct tape to go over where the rubber meets the metal on the flexible joint???
    Just till I can save up enough to fix it the correct way.
    Once again Thank You so much for your video. These kind of videos really helps when one isn't properly educated in the field. My degrees are math/logic Accounting Degree and Computer Programming Degree

  • @THANHPHONGCOLTD
    @THANHPHONGCOLTD 4 ปีที่แล้ว +1

    is elmer adhensive good?

  • @sean8134
    @sean8134 4 ปีที่แล้ว +1

    do these up the static pressure much?

  • @dineshbhoibhoi583
    @dineshbhoibhoi583 ปีที่แล้ว

    Sir you have vacancy I am hvac air conditioner duct fitter and 15 years experience Gulf country in Kuwait

  • @lmlabs8455
    @lmlabs8455 6 ปีที่แล้ว +1

    why do we use flexible connector

    • @lmlabs8455
      @lmlabs8455 6 ปีที่แล้ว +1

      between duct and ahu or fcu machine

    • @hangngoaigiare
      @hangngoaigiare 5 ปีที่แล้ว +1

      for easy connect supply and return trunk to furnace